SCSI Commands
5-84
Quantum DLT 4000 Tape Drive
MODE SELECT (6) / (10) Command (15h) / (55h) (continued)
5.9.8 EEPROM Vendor Unique Page (3Eh)
The drive supports a vendor unique page that enables a user to modify savable
parameters. Only one savable parameter may be changed per Mode Select
command.
Bit
Byte
7
6
5
4
3
2
1
0
0
PS
Rsvd
Page Code (3Eh)
1
Additional Page Length
2
ASCII String of Parameter Name and Value
Figure 5–40 EEPROM Vendor Unique Page - Data Format
The ASCII string has a parameter name, followed by one or more space
characters, a parameter value, and an ASCII line feed or null character. When
the string is parsed, the parameter value is interpreted as shown in the following
table. Note that the parameter name may be in upper or lower case. The savable
parameters are saved over resets and power cycles.
Table 5–43 EEPROM Vendor Unique Page Parameters
Name
Value
Rep.
Default
Length
(Bytes)
Usage
VENDORID
ASCII
QUANTUM
8
Vendor Identification field in INQUIRY
Data
PRODUCTID
ASCII
DLT4000
16
Product Identification field in INQUIRY
Data
Содержание DLTtape DLT 4000
Страница 1: ...DLT 4000 Tape Drive Product Manual November 10 2003 81 60043 04 ...
Страница 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued ...
Страница 6: ......
Страница 24: ...About This Manual Quantum DLT 4000 Tape Drive xxiv ...
Страница 62: ...Hardware Implementation 2 28 Quantum DLT 4000 Tape Drive ...
Страница 100: ...Messages 4 12 Quantum DLT 4000 Tape Drive ...
Страница 264: ...SCSI Commands 5 164 Quantum DLT 4000 Tape Drive ...
Страница 274: ...Appendix B EEPROM Resident Bugcheck and Event Logs B 6 Quantum DLT 4000 Tape System ...
Страница 280: ...Appendix C Updating the Firmware C 6 Quantum DLT 4000 Tape Drive ...
Страница 298: ...Index Index 6 Quantum DLT4000 Tape Drive ...
Страница 299: ......