SCSI Commands
Quantum DLT 4000 Tape Drive
5-45
LOG SENSE Command (4Dh) (continued)
Bit
Byte
7
6
5
4
3
2
1
0
0 -1
(MSB)
Parameter Code
(LSB)
2
DU
DS
TSD
ETC
TMC
Rsvd
LP
3
Parameter Length
4 - 11
(MSB)
Parameter Value
(LSB)
NOTE:
Byte 2 is also referred to the Parameter Control Byte.
Figure 5–18 Log Parameters Format for Read / Write Error LOG SENSE Page
Table 5–21 Log Parameters for Read / Write Error LOG SENSE Page Field Descriptions
Field Name
Description
Parameter
Code
Parameter Codes supported for the READ/WRITE error counter pages are as follows:
Parameter Code - Description
00h - Errors corrected with substantial delays
01h - Errors corrected with possible delays
02h - Total rewrites or rereads
03h - Total errors corrected
04h - Total times correction algorithm processed
05h - Total bytes processed
06h - Total uncorrected errors
Содержание DLTtape DLT 4000
Страница 1: ...DLT 4000 Tape Drive Product Manual November 10 2003 81 60043 04 ...
Страница 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued ...
Страница 6: ......
Страница 24: ...About This Manual Quantum DLT 4000 Tape Drive xxiv ...
Страница 62: ...Hardware Implementation 2 28 Quantum DLT 4000 Tape Drive ...
Страница 100: ...Messages 4 12 Quantum DLT 4000 Tape Drive ...
Страница 264: ...SCSI Commands 5 164 Quantum DLT 4000 Tape Drive ...
Страница 274: ...Appendix B EEPROM Resident Bugcheck and Event Logs B 6 Quantum DLT 4000 Tape System ...
Страница 280: ...Appendix C Updating the Firmware C 6 Quantum DLT 4000 Tape Drive ...
Страница 298: ...Index Index 6 Quantum DLT4000 Tape Drive ...
Страница 299: ......