SCSI Commands
5-46
Quantum DLT 4000 Tape Drive
LOG SENSE Command (4Dh) (continued)
Table 5–21 Log Parameters for Read / Write Error LOG SENSE Page Field Descriptions
(continued)
Field Name
Description
Parameter Code
(continued)
8000h - Vendor Unique
Note:
Parameter codes 00h, 01h, and 04h always return a value of 0. Parameter
value for 05h is 8 bytes; the parameter length is set to 8.
DU
Disable Update. This field with a value 0 indicates that the target will update all
log parameter values. This field set to 1 indicates that the target will not update
the log parameter values except in response to LOG SELECT. This bit is set by the
drive when accumulated values reach maximum. This is also returned set to 1 if
the host set the bit in the last LOG SELECT command. Default is 0.
Note that for parameter types other than threshold and cumulative values, this
bit is always 0.
DS
Disable Save. Not supported; always set to 1.
TSD
Target Save Disable. Not supported; always set to 1.
ETC
Enable Threshold Comparison. When set to 1, indicates that comparison to
threshold is performed. ETC of 0 indicates that the comparison is not performed.
This bit is set to 1 by MODE SELECT. Default is 0.
TMC
Threshold Met Criteria. This field is valid only if host sets ETC to 1. It determines
the basis for comparison and is specified by host using LOG SELECT. If the result
of comparison is true (cumulative = threshold), and MODE SELECT / SENSE
CONTROL MODE page RLEC bit is set to 1, then a UNIT ATTENTION is granted for
all initiators. The sense key is set to UNIT ATTENTION, the additional sense code
to LOG EXCEPTION, and ASCQ is set to THRESHOLD CONDITION MET. If the RLEC
bit in CONTROL MODE page is 0, then UNIT ATTENTION is not generated.
Note that comparison is performed in real time. A Log Sense command need
not be issued to get the CHECK CONDITION. Once ETC is selected, RLEC bit in
control mode page, the CHECK CONDITION is issued based on the criteria
defined in the TMC bits if the criteria are met in real time. CHECK CONDITION will
not identify for which parameter code the criteria is met. Log Sense must be
issued to read the counters to determine for which parameter code criteria has
been met.
Содержание DLTtape DLT 4000
Страница 1: ...DLT 4000 Tape Drive Product Manual November 10 2003 81 60043 04 ...
Страница 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued ...
Страница 6: ......
Страница 24: ...About This Manual Quantum DLT 4000 Tape Drive xxiv ...
Страница 62: ...Hardware Implementation 2 28 Quantum DLT 4000 Tape Drive ...
Страница 100: ...Messages 4 12 Quantum DLT 4000 Tape Drive ...
Страница 264: ...SCSI Commands 5 164 Quantum DLT 4000 Tape Drive ...
Страница 274: ...Appendix B EEPROM Resident Bugcheck and Event Logs B 6 Quantum DLT 4000 Tape System ...
Страница 280: ...Appendix C Updating the Firmware C 6 Quantum DLT 4000 Tape Drive ...
Страница 298: ...Index Index 6 Quantum DLT4000 Tape Drive ...
Страница 299: ......