6. Cleaning of the cooling unit
Casing: Before cleaning the units disconnect the mains plug! Please do not use water
directly on the unit, clean only with a wet cloth and a little dish liquid. The cleaning of
the units and the beverage coils (optional for this unit, if used) have to take place
according to the instructions of the industrial safety regulations.
Prevent any moisture from getting into the electric part of the unit!
The condenser fins should be cleaned at regular intervals (min. every six months and
more frequently if required) by qualified personnel to remove the accumulated air dust.
7. Troubleshooting
Error
Possible cause
Error correction
The unit
does not
start
No main connection
No water in the tank
Thermostat is disconnected
Thermostat does not close circuit
Starting device at the compressor is
defect
Interference of the compressor
(interwinding fault)
Establish main connection
(plug the unit)
Fill in water
Switch on the Thermostat
Change the Thermostat
Exchange the starting
device (relay and
condenser)
Change the compressor
Unit is
running,
but does
not cool
The condenser is blocked with dirt
Failure of the condenser fan
Leakage in the refrigeration system
Compressor interference
Clean the condenser
Exchange the fan
Repair the leakage,
evacuate gas, and fill with
the refrigerant gas
(R134a)
Exchange the compressor
Unit does
not switch
off
Thermostat defect
Leakage in the refrigeration system
Cooling demand is to large
Exchange Thermostat
Repair the leakage, and fill with
the refrigerent (R134a)
Control the cooling
demand and if necessary
reduce the cooling load
All these works have to be carried out by skilled and qualified personnel!
Should it not be possible to take care of the failure, please contact the responsible
service.