background image

 

 

 

Table of contents 
 

 

 

 

 

 

 

 

 

 

 

 

         Page 

 

1. Safety instructions ............................................................................................................................... 3 

1.1 Installation and commissioning ..................................................................................................... 3 

1.2 Safety information .......................................................................................................................... 3 

1.2.1 Impairment of safety ................................................................................................................... 4 

1.2.2 Safety instructions ...................................................................................................................... 4 

1.3 Spare parts .................................................................................................................................... 4 

1.4 Transport/Storage .......................................................................................................................... 4 

1.5 Electrical installation ...................................................................................................................... 4 

1.6 Service ........................................................................................................................................... 4 

2. Intended use ........................................................................................................................................ 4 

3. Commissioning .................................................................................................................................... 5 

3.1 Connection .................................................................................................................................... 5 

3.2 Chart .............................................................................................................................................. 6 

4. Decommissioning ................................................................................................................................ 7 

5. Temperature setting ............................................................................................................................ 7 

6. Cleaning of the cooling unit ................................................................................................................. 9 

7. Troubleshooting ................................................................................................................................... 9 

8. Noise emission .................................................................................................................................. 10 

9. Technical Data ................................................................................................................................... 10 

10. Declaration of conformity ................................................................................................................. 10 

 

 

 

 

 

 

 

 
 

 

 

 
 
The described cooling unit may only be put into operation, if the operator is sufficiently trained and the 
operating and maintenance personnel have studied this instruction manual in detail. 

Содержание GLY401

Страница 1: ...NICHILLY SB COMPATIBLE 115V WTG Quantor GmbH Europa Allee 53 D 54343 F hren Phone 49 0 6502 999 95 0 Fax 49 0 6502 999 95 75 eMail info quantor technology Homepage www quantor technology GB Attention...

Страница 2: ...4 1 6 Service 4 2 Intended use 4 3 Commissioning 5 3 1 Connection 5 3 2 Chart 6 4 Decommissioning 7 5 Temperature setting 7 6 Cleaning of the cooling unit 9 7 Troubleshooting 9 8 Noise emission 10 9 T...

Страница 3: ...clean from any dirt fiber etc Make sure to connect the unit to the required supply voltage Protect the unit from moisture no fluids may enter the electric parts Observe the warning and safety informa...

Страница 4: ...consulted with the manufacturer The unit may only be stored in a dry dust free environment at temperature of 0 C to 40 C 1 5 Electrical installation All electrical installations are to be carried out...

Страница 5: ...used to connect the plastic tubes Such kits are not provided with the unit If used please connect them according to the instructions of the manufacturer 4 Close the lid Do not operate the unit when i...

Страница 6: ...omp 1 Water level gauge and tank emptying 4 Thermostatic controller 2 Cover fastener 5 Small pipes for water return flow 3 Connections 3 8 5 Expansion valve 8 Water tank 6 Condenser 9 Evaporator cooli...

Страница 7: ...the unit with clear water only without Glycol or remnants of Glycol in the water system Recommended set point temperature for using an ice bank 1 0 C 30 2 F ATTENTION to avoid damage on the unit free...

Страница 8: ...water mixture approx 30 propylene glycol Please pay attention that the water bath temperature must not fall below 6 C and must not exceed 30 C Controller activation for a minimum set point down to 6...

Страница 9: ...Starting device at the compressor is defect Interference of the compressor interwinding fault Establish main connection plug the unit Fill in water Switch on the Thermostat Change the Thermostat Exch...

Страница 10: ...s steel Mobile on wheels 10 Declaration of conformity We WTG Quantor GmbH D 54343 F hren declare in sole responsibility that the cooling units MiniCHILLY 05 MiniCHILLY 09 and MiniCHILLY 17 which this...

Страница 11: ...11...

Страница 12: ...E D I E N U N G S A N L E I T U N G I N S T R U C T I O N M A N U A L I N S T R U C T I O N S D E S E R V I C E M A N U A L D E I N S T R U C C I O N E S Doc ID 2018 06 SBComp115V www quantor technol...