8. Noise emission 

 

70 dB (A) data according to EN 292 part 2 A1 
At level, which are lower as or equal 70 dB (A), the inscription "70 dB (A)" is adequate.  

 
 
 
 

9. Technical Data 

 

 

  Refrigerant: 

 

R134a

 

  Voltage:  

 

115 V / 1 Ph / 60 Hz

 

  Water tank volume: 

27 l 

(MiniCHILLY 05 SB Comp und 09 SB Comp)

 

48 l 

(MiniCHILLY 17 SB Comp)

 

  Water connections:  

3/8” 

  Casing:   

 

Stainless steel

 

  Mobile on wheels

 

 
 
 

10. Declaration of conformity 

 
 

We,  WTG-Quantor  GmbH,  D-54343  Föhren,  declare  in  sole  responsibility  that  the  cooling  units 
MiniCHILLY  05, MiniCHILLY 09  and MiniCHILLY  17  which this declaration refers to, comply with the 
following standards and normative documents. 
 
- EN 60204-1 (VDE 0113) 
- DIN 6650 
 
In accordance with the low-voltage directive 2014/35/EU, EG 1935/2004. 
 
This declaration becomes void for any modification of the units not agreed with us. 
 
Föhren, 19.07.2016 
 

                      
…………………………………………………… 

Markus Milz 
Managing director WTG-Quantor GmbH 

 
 
 
 
 
 
 
 
 
 
 

Содержание GLY401

Страница 1: ...NICHILLY SB COMPATIBLE 115V WTG Quantor GmbH Europa Allee 53 D 54343 F hren Phone 49 0 6502 999 95 0 Fax 49 0 6502 999 95 75 eMail info quantor technology Homepage www quantor technology GB Attention...

Страница 2: ...4 1 6 Service 4 2 Intended use 4 3 Commissioning 5 3 1 Connection 5 3 2 Chart 6 4 Decommissioning 7 5 Temperature setting 7 6 Cleaning of the cooling unit 9 7 Troubleshooting 9 8 Noise emission 10 9 T...

Страница 3: ...clean from any dirt fiber etc Make sure to connect the unit to the required supply voltage Protect the unit from moisture no fluids may enter the electric parts Observe the warning and safety informa...

Страница 4: ...consulted with the manufacturer The unit may only be stored in a dry dust free environment at temperature of 0 C to 40 C 1 5 Electrical installation All electrical installations are to be carried out...

Страница 5: ...used to connect the plastic tubes Such kits are not provided with the unit If used please connect them according to the instructions of the manufacturer 4 Close the lid Do not operate the unit when i...

Страница 6: ...omp 1 Water level gauge and tank emptying 4 Thermostatic controller 2 Cover fastener 5 Small pipes for water return flow 3 Connections 3 8 5 Expansion valve 8 Water tank 6 Condenser 9 Evaporator cooli...

Страница 7: ...the unit with clear water only without Glycol or remnants of Glycol in the water system Recommended set point temperature for using an ice bank 1 0 C 30 2 F ATTENTION to avoid damage on the unit free...

Страница 8: ...water mixture approx 30 propylene glycol Please pay attention that the water bath temperature must not fall below 6 C and must not exceed 30 C Controller activation for a minimum set point down to 6...

Страница 9: ...Starting device at the compressor is defect Interference of the compressor interwinding fault Establish main connection plug the unit Fill in water Switch on the Thermostat Change the Thermostat Exch...

Страница 10: ...s steel Mobile on wheels 10 Declaration of conformity We WTG Quantor GmbH D 54343 F hren declare in sole responsibility that the cooling units MiniCHILLY 05 MiniCHILLY 09 and MiniCHILLY 17 which this...

Страница 11: ...11...

Страница 12: ...E D I E N U N G S A N L E I T U N G I N S T R U C T I O N M A N U A L I N S T R U C T I O N S D E S E R V I C E M A N U A L D E I N S T R U C C I O N E S Doc ID 2018 06 SBComp115V www quantor technol...

Отзывы: