SOFTPRO INSTALLATION GUIDE
©2022 SoftPro Water Systems. All rights reserved.
19
.
NEW INSTALL PLUMBING GUIDE
Refer to the appropriate new installation scenario.
This guide is intended as a general reference. Your specific installation may vary from this guide.
A.
NEW INSTALL WITH A PRE-PLUMBED WATER SOFTENER LOOP
B.
NEW INSTALL ON A WATER HEATER LOOP
C.
NEW INSTALL BY RE-ROUTING A HOME’S WATER SUPPLY LINE
D.
NEW INSTALL FOR PRIVATE WELL WATER
CAUTION: CUTTING COPPER PIPES?
Install grounding straps prior to cutting.
NOTE
: Use the appropriate cutting tool for the different types of pipes (copper, PVC, PEX, CPVC, etc.).
A) NEW INSTALL WITH A PRE-PLUMBED WATER SOFTENER LOOP
1)
Switch-off the breaker to the hot water heater. At the electrical control panel, temporarily switch off the power
feeding the water heater unit.
2)
Shut-off the water main.
3)
Drain any existing water from both the cold and hot water pipes.
Simply, open all of the sink and bathtub faucets to empty the remaining water in the pipes. Drain completely.
TIP:
In addition, you can also remove a shower head (since it is located high) to create a vacuum so pipes can
drain better.
4)
Cut the water line softener loop and cut/ unplug the appropriate drain line. Place a bucket to catch the water from
the softener loop.