Assemble all tools needed to install the unit. Start your Installation. If copper, you need a
copper cutter, propane tank, soldering torch, flux, wire paper and lead free solder. An
average cost of $40.00 NOW THAT YOU HAVE ADDED THE RESIN AND CONNECTED THE
CONTROL VALVE TO THE TANK YOU ARE READY TO INSTALL, FOLLOW THESE
INSTRUCTIONS:
1
. Turn off the main water shutoff valve.
2
. Open all plumbing fixtures in the house including all outside faucets in order to drain the
lines. Unscrewing the aerator screen from your kitchen and bathroom faucets will help drain
the lines faster
3
. Cut and remove a 4" section of the water line where the unit is to be installed.
4
. Remove the two stainless steel clamps that are connected between the stainless steel bypass
valve and the plastic meter assembly, there is one clamp on each side. Remove the bypass
valve from the meter assembly by pulling it away from the meter assembly.
.
5
. Leave the meter assembly in place.
6
. We do not recommend applying heat from a soldering torch to solder copper pipe to your
new valve/meter assembly. To help with this:
Solder a 3" to 5" piece of ¾" OR 1" copper pipe into each male adapter.