22
01/21
7082-153K
Install batteries
(Figure 22.2)
Figure 22.2
I. Location & Mounting of User Interface
NOTE:
See user interface manual on how to operate the
user interface.
Figure 22.3
Level
To ensure you have a reliable Bluetooth Connection locate
the user interface:
• Maximum distance of 30 foot from appliance
• On an interior wall
• 5 feet from the floor
• Not behind doors, bookcases or other objects
• Away from drafts and direct heat from the appliance
NOTICE:
Verify stable connection before mounting the
user interface.
NOTICE:
DO NOT use if not properly mounted to a wall.
While we state a maximum range of 30 feet, we recommend
pairing the user interface to the appliance and accessing the
diagnostics menu to view the Bluetooth signal strength prior
to selection of final mounting location for the user interface.
While viewing the signal strength on the diagnostics menu,
move the user interface to the desired location and look at
the signal strength.
• Ideally, the user interface should be located where the
signal strength is better than -78db. The closer the
number is to 0, the better the signal strength.
• Occasionally, the signal strength may decrease to as low
as -79db, which is considered normal.
• However, a steady wireless signal strength of -79db may
still connect and function, but may affect the reliability of
the Bluetooth connection.
Mount base plate using screws and anchors provided
using the level as a guide as shown in
Figure 22.3
. It is
recommended to mount at least one screw into a stud. If
necessary drill 3/16 holes for drywall or drill 7/32 for plaster.
Figure 22.1
H. Power to Appliance and User Interface
1. Prior to installing the power cord, turn the user interface
to OFF.
2. Make sure the was receptacle has 120 VAC output.
NOTE:
Using a circuit protector can protect the appliance
circuits from power surges.
3. The appliance receptacle is located on its lower, back
right hand corner. Install the cord to the appliance
reception and to the wall
(Figure 22.1)
.
- This will cause the combustion blower to turn on for
approximately 45 seconds and run a systems check.
Shock hazard.
• Do NOT remove grounding prong
from plug.
• Plug directly into properly grounded 3
prong receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front
of appliance.
CAUTION