background image

19

01/21

7082-153K

Abaisser le nivellement

Boulons si nécessaire 

pour Conserver le 

niveau d'insertion Lors 

de l'installation.

Figure 19.2

 - OAK Exploded View

A. Leveling System

The leveling bolts are located on the sides of the appliance, 

front and rear. To access the bolts, remove the front access 

panels. Reach in and turn the bolt to the desired height to 

level the appliance

 (Figure 19.1)

.

B. Outside Air Kit Instructions

3 INCH (76mm) ALUMINUM FLEX PIPE NOT INCLUDED

1.  Measure  distance  from  floor  to  air  vent  opening  in 

appliance and mark location on wall.

2.  Use  saw  to  cut  opening  in  wall.  Cut  a  3-1/2  to  4  inch 

(89-102mm) opening on inside wall and a 4 to 4-1/2 inch 

(102-114mm) opening on outside of house.

3.  Use wire ties to secure flex pipe to collar assembly.
4.  Slide trim ring over flex pipe and run pipe through wall.
5.  Attach flex pipe (not included) to outside termination cap 

with second wire tie 

(Figure 19.2)

.

6.  Secure termination cap to outside surface.
7.  Secure trim ring to interior wall.

C. Removal of Cast Sides

Remove the cast side by releasing the upper, spring-loaded 

latch 

(Figure 19.3)

.  Access  the  latch  through  the  upper 

panel vent holes. The cast panel should fall forward. Lift it 

out of its lower nest and set the panel aside.

Appliance Set-Up 

Figure 19.1

Lower the leveling

bolts if necessary to

keep the insert level

when installing.

Never draw outside combustion air from:

• 

Wall, floor or ceiling cavity

• 

Enclosed space such as an attic or garage

CAUTION

Figure 19.3

 - Shown with Cast Panel Set

Collar

Wire Ties

Trim Ring

Termination Cap

3 inch Aluminum Flex

Pipe (not included)

Содержание TREKKERI-MBK

Страница 1: ...Failure to comply may cause house fire NOTE To obtain a French translation of this manual please contact your dealer or visit www quadrafire com REMARQUE Pour obtenir une traduction fran aise de ce ma...

Страница 2: ...Dimensions 8 B Clearance to Combustibles US CAN 9 C Masonry Chimney and Fireplace Clearances 10 D Minimum Opening for Masonry ZC Fireplaces 10 E Hearth Extension 11 F Floor Protection 11 G Installati...

Страница 3: ...fication Number Number 98 17 EPA Certified Emissions 0 74 grams per hour LHV Tested Efficiency 83 2 HHV Tested Efficiency 77 9 EPA BTU Output 12 700 to 39 400 hr BTU Input 16 400 to 50 800 hr Vent Siz...

Страница 4: ...ntally exiting the room and a smoke CO alarm be installed in the bedroom The size of the room must be at least 50ft per 1 000 Btu hr stove input if the stove exceeds the room size out air must be inst...

Страница 5: ...appliance where there will be a clear passage for a Listed chimney through the ceiling and roof vertical or through exterior wall horizontal Installing the required outside air kit will affect the lo...

Страница 6: ...rts and articles packed inside the Component Pack Inspect all the parts and glass for shipping damage Report to your dealer any parts damaged in shipment All labels have been removed from the glass do...

Страница 7: ...ng this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the appliance Check...

Страница 8: ...5 Front View with Basic Surround Panel Set 33 in 838mm 50 in 1270mm 34 1 2 in 876mm 45 in 1143mm 11 3 4 in 297mm 18 1 2 in 469mm Figure 8 2 Front View with Cast Panel Set 23 7 8 in 606mm 32 in 814mm 2...

Страница 9: ...be added to this dimension Figure 9 1 Built in Appliance Rear Vent NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actu...

Страница 10: ...he height from the hearth to the bottom of the mantel is 39 3 4 inches Table 10 1 Minimum Opening Dimensions Inches Millimeters A Height 24 3 8 619 B Front Width Steel Panel Set 32 1 4 819 Front Width...

Страница 11: ...f the fireplace with screws or nails stating that the fireplace may have been altered to accommodate the insert and must be returned to original condition for use as a conventional fireplace Figure 11...

Страница 12: ...gHTrequirements or if the factory built fireplace was tested prior to 1998 a full height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be secu...

Страница 13: ...12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table below 24 in Above grass top of plants...

Страница 14: ...mands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appliance It may be necessary to add additional ventilation to t...

Страница 15: ...iance and chimney NOTICE Hearth Home Technologies assumes no responsibility for the improper performance of the chimney system caused by Inadequate draft due to environmental conditions Down drafts Ti...

Страница 16: ...llation Figure 16 2 1 Locate the calculated equivalent feet of pipe on the vertical left side of the chart 2 Move to the right horizontally on the chart until you reach your altitude above sea level 3...

Страница 17: ...rances carefully for this type of installation to ensure adequate room for outside air venting B Full Reline with Outside Air Vertical Figure 17 2 NOTE Use metal plate around exhaust vent pipe and sea...

Страница 18: ...ound exhaust vent pipe and seal all edges with non flammable insulation such as fiberglass mineral wool or ceramic material DO NOT use high temperature cauling materials to seal any edge to prevent fu...

Страница 19: ...of house 3 Use wire ties to secure flex pipe to collar assembly 4 Slide trim ring over flex pipe and run pipe through wall 5 Attach flex pipe not included to outside termination cap with second wire t...

Страница 20: ...ces 2 cast trim legs and 1 cast trim header underneath the panel set also face down 6 Place washer provided over tab and secure the trim and panel together with screw Continue for all tabs 7 Secure ca...

Страница 21: ...s Right Log Figure 21 3 Figure 21 4 F Optional Log Set Instructions 2 PIECE LOG SET INSTALLATION 1 Place the left log as shown There are 2 indentations in the bottom of the log to fit over the screw h...

Страница 22: ...n 78db The closer the number is to 0 the better the signal strength Occasionally the signal strength may decrease to as low as 79db which is considered normal However a steady wireless signal strength...

Страница 23: ...Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 23 1 7 7 Mobile Home Installation Products of combustion generate carbon monoxide and different fuels generate different l...

Страница 24: ...24 01 21 7082 153K Date of Service Performed By Description of Service A Service Maintenance Log 8 8 Refrence Materials...

Страница 25: ...25 01 21 7082 153K Date of Service Performed By Description of Service...

Страница 26: ...Set 2 Pc Sold as set only LOGS 60 AE B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Flue Adapter Required if TPVNT 4 is removed LKADP Surround Std Panel For Cast Trim SP MTVS CST Component Pack 70...

Страница 27: ...3 8 x 4 223 0140 Nut Wing 1 4 20 Pkg of 12 226 0110 12 Y Screw Sheet Metal 8 X 1 2 S Grip Pkg of 40 12460 40 Y Washer Sae Pkg of 25 227 0080 25 Y Washer FI 1 4 Black Pkg of 10 1202473 10 Pkg of 50 120...

Страница 28: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: