G. Error Codes
If a system error occurs that forces the system to stop op
-
erating an error screen appears. Depending upon the error
type, up to three retry attempts are allowed after which a
service professional is required.
Press the ERROR LIST button to display the latest error.
Figure 10.1.
See
page 11
for a list of error codes.
F. Service Information
The SERVICE INFORMATION screen displays contact in
-
formation for Hearth & Home Technologies Customer Ser
-
vice Line. The local dealer may have changed this upon or
before the installation to indicate a dealer hot line.
www.quadrafire.com
to locate your nearest
dealer
DONE
ERROR LIST
Figure 10.2
MANUAL LIGHT PROCEDURE
Press “CONTINUE”
button to start manual
lighting sequence
Current Tem: 72 F
O
CONTINUE
MANUAL LIGHT PROCEDURE
Please wait while
feed charge is loading
into firepot
MANUAL LIGHT PROCEDURE
Open door...
Manually light fuel...
Close door
Figure 10.1
13 Volts
12 Volts
11 Volts
Battery
Below
10 Volts
Operating on Battery Back-Up
•
A battery icon appears on your wall control to let you
know you are now operating on battery power.
Figure
10.3.
• The fire must be manually lit as the appliance will no
longer automatically light.
See page 4
.
•
Use only approved fire starting gel to start the fire.
• The high burn rate is no longer available on battery
back-up.
• Each level drops down one level, i.e the high burn be
-
comes medium-high burn and so on.
• If the battery charge falls below 10 volt it can no longer
sustain the appliance operation and the appliance will
shut down. You must disconnect and reconnect the bat
-
tery to start it up again.
Recommended Battery
• 12 volt deep cycle battery, (i.e., marine or RV type).
•
A 12 volt battery cable is available through your local
dealer.
Figure 10.3
MAINT BURN
73
Set at: 73
12:30 PM
HEAT OUTPUT
MENU
“Maint Burn” will display when
the thermostat has reached the
set room temperature and will
run on low until it reaches its
auto-clean clycle time.
Battery icon.
Figure 10.4
Wall Control Display
The wall control will display the battery icon when operating
in the battery back-up mode.
Figure 10.4.
H. Battery Back-up System (Optional)
The appliance has been designed to operate on an optional
battery back-up system.
If you have frequent power outages in your region, hook
the appliance up to a 12 volt battery and it will automatically
switch to battery power in the event of a power failure. The
12 volt power cord sold as a separate accessory does not
charge the battery.
Refer to the Owner’s Manual for your appliance for instructions
on how to attach the cable to your appliance. The following