background image

Page  10

7014-101F

April 1, 2009

G. Error Codes

If a system error occurs that forces the system to stop op

-

erating an error screen appears. Depending upon the error 

type,  up  to  three  retry  attempts  are  allowed  after  which  a 

service professional is required.  

Press  the  ERROR  LIST  button  to  display  the  latest  error.  

Figure 10.1.

  See 

page 11

 for a list of error codes.

F.  Service Information

The SERVICE INFORMATION screen displays contact in

-

formation for Hearth & Home Technologies Customer Ser

-

vice Line.  The local dealer may have changed this upon or 

before the installation to indicate a dealer hot line.

www.quadrafire.com

 to locate your nearest 

dealer

DONE

ERROR LIST

Figure 10.2

MANUAL LIGHT PROCEDURE

Press “CONTINUE”

 button to start manual

 lighting sequence

Current Tem:  72  F

O

CONTINUE

MANUAL LIGHT PROCEDURE

Please wait while

feed charge is loading

into firepot

MANUAL LIGHT PROCEDURE

Open door...

Manually light fuel...

Close door

Figure 10.1

13 Volts 

12 Volts

11 Volts

Battery 

Below 

10 Volts

Operating on Battery Back-Up

• 

A battery icon appears on your wall control to let you 

know you are now operating on battery power.  

Figure 

10.3.

•  The fire must be manually lit as the appliance will no 

longer automatically light.  

See page 4

.

• 

Use only approved fire starting gel to start the fire. 

•  The  high  burn  rate  is  no  longer  available  on  battery 

back-up.

•  Each level drops down one level, i.e the high burn be

-

comes medium-high burn and so on.

•  If the battery charge falls below 10 volt it can no longer 

sustain the appliance operation and the appliance will 

shut down.  You must disconnect and reconnect the bat

-

tery to start it up again.

Recommended Battery
•  12 volt deep cycle battery, (i.e., marine or RV type).  

• 

A 12 volt battery cable is available through your local 

dealer.

Figure 10.3

MAINT BURN

73

Set at:  73

12:30 PM

HEAT OUTPUT

MENU

“Maint Burn” will display when 

the thermostat has reached the 

set room temperature and will 

run on low until it reaches its 

auto-clean clycle time.

Battery icon.

Figure 10.4

Wall Control Display
The wall control will display the battery icon when operating 

in the battery back-up mode.  

Figure 10.4.

H.  Battery Back-up System (Optional)

The appliance has been designed to operate on an optional 

battery back-up system.  
If  you  have  frequent  power  outages  in  your  region,  hook 

the appliance up to a 12 volt battery and it will automatically 

switch to battery power in the event of a power failure.  The 

12 volt power cord sold as a separate accessory does not 

charge the battery.  
Refer to the Owner’s Manual for your appliance for instructions 

on how to attach the cable to your appliance.  The following 

are the screens you will see when using a back-up battery.

Содержание SRV7000-451

Страница 1: ...LE OF CONTENTS Check building codes prior to installation Installation MUST comply with local regional state and national codes and regulations Consult local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits CAUTION Hearth Home Technologies 1445 North Highway Colville WA 99114 Division of HNI INDUSTRIES CONTACT INFORMATION Please cont...

Страница 2: ... is in start up cycle and is in the process of lighting an initial charge of fuel b SS LOW or SS MED SS soft start Indicates the soft start portion of the lighting sequence In these stages the fire begins to gradually build to operating temperature c AUTO x or MAN x x heat output level Indicates both the operating cycle automatic or manual and the current heat output level The heat output level wi...

Страница 3: ...re of the room where the wall control is located The tempera ture displayed can be in units of Fahrenheit or Celsius The desired units can be selected via the system menu See Figure 6 5 on page 6 1 Set Comfort Level Temperature The most basic operation of the wall control is to turn the appliance on or off depending on the requirement for heat From the main screen the SET COMFORT LEVEL screen can ...

Страница 4: ...esired fuel type and then press the button under Se lect The arrow will change to indicate the currently select ed fuel NOTE If you are burning a high ash fuel set the fuel selec tion to Utility Pellets When purchasing corn or wheat to burn in your appliance read the ingredient label very carefully Do NOT purchase fuel that contains any additives such as oils i e soybean oil and meals as it will r...

Страница 5: ...aking changes or if you just en tered the programming screen to view the set program press Done or let the display return to the main screen automatically PROGRAM Full Week Wake 6 30 AM 68 F o Day 7 59 AM 68 F o Evening 4 00 PM 68 F o Night 11 00 PM 68 F o DONE SET NEXT PROGRAM Full Week Wake 6 30 AM 68 F o Day 7 59 AM 68 F o Evening 4 00 PM 68 F o Night 11 00 PM 68 F o DONE SET NEXT PROGRAM Full ...

Страница 6: ...28 September 2007 28 Figure 6 1 Figure 6 2 Figure 6 3 6 User Settings Items that are rarely changed are stored under the USER SETTINGS a Temp Units F C The TEMP UNITS screen is used to change from Fahren heit to Celsius and back for the temperatures displayed b Flame Height Adjust The FLAME HEIGHT ADJUST screen is used to adjust the flame height fuel feed rate for specific installation and fuel ty...

Страница 7: ... Figure 7 3 f Elevation The ELEVATION screen allows you to adjust the appliance to your specific elevation Press the UP DOWN buttons to select your elevation The message in the center will change between NORMAL and HIGH If you select HIGH it will replace the normal fuel tables with specific high fuel tables You MUST select a fuel type after selecting HIGH Please note that changing the elevation wi...

Страница 8: ...e Turning on appliance 7 Fill the hopper with fuel If the hop per was completely empty or has run out of fuel put approximately 1 2 cup of pellets into the firepot for a quick restart 8 Be sure the hopper lid and glass door are both closed 1 At the starting screen press MENU Function Buttons Buttons Up Down READY 73 Set at 73 12 30 PM HEAT OUTPUT MENU Room Temp Wall Control for Reference 6 Press D...

Страница 9: ...Temp SERVICE RETRY ERROR LIST 1 If the appliance has stopped operat ing check the wall control screen If it is showing Min Firepot Temp the hopper has run out of fuel 2 Fill the hopper with fuel and press the RETRY button twice The first time turns on the back light the sec ond time starts the retry function 3 If the wall control screen changes to a SHUTDOWN screen that means your appliance has no...

Страница 10: ...ly approved fire starting gel to start the fire The high burn rate is no longer available on battery back up Each level drops down one level i e the high burn be comes medium high burn and so on If the battery charge falls below 10 volt it can no longer sustain the appliance operation and the appliance will shut down You must disconnect and reconnect the bat tery to start it up again Recommended B...

Страница 11: ...Pull the feed system and inspect Clear jam and then press Retry button MISSED IGNITION Igniter bad or poor harness connection Out of fuel or fuel is bridging in hopper Faulty firepot thermocouple connection is shorted Check connections if OK replace igniter Break up bridging pellets Refill hopper Replace the thermocouple press Retry MIN FIREPOT TEMP Out of fuel Refill hopper Add handful of pellets...

Страница 12: ...774802 6796302 6840261 6848441 6863064 6866205 6869278 6875012 6880275 6908039 6919884 D320652 D445174 D462436 Canada 1297749 2195264 2225408 2313972 Australia 780250 780403 1418504 or other U S and foreign patents pending Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer phone Notes We recommend that you record the following pertinent information for yo...

Отзывы: