Model

PS35-C

Laboratory

Intertek

Report No.

3198406PRT-002

Type

Solid Fuel Room Appliance/Pellet Fuel 

Burning Type

Standard

ASTM E1509-04, ULC S627-00 Room 

Appliance Pellet Fuel Burning type and 

(UM) 84-HUD,

Mobile Home Approved.

Model

PS35-C

Laboratory

OMNI Test Laboratories, Inc.

Report No.

0061PS086E

Standard

Method 28R, ASTM E1509-04 and 

ASTM E2779

Can be found at:

www.quadrafire.com/about-us/epa-certification

Important Safety Information

A. Appliance Safety Certification

B. Appliance Emissions Certification

NOTICE:

 This installation must conform with local codes. In the absence of local codes you must comply with the 

ASTM E1509-04, ULC S627-00, (UM) 84-HUD and  ULC/ORD-C-1482

C. BTU & Efficiency Specifications

EPA Certification 

Number:

Number: N/A

EPA Certified Emissions:

1.0 grams per hour

*LHV Tested Efficiency:

73.6%

**HHV Tested Efficiency:

68.8%

***EPA BTU Output:

8,600 to 29,700 per hour

****BTU Input:

12,600 to 41,900 per hour

Vent Size:

3” or 4” Type “L” or “PL”

Hopper Capacity:

45 lbs.

Fuel:

Premium Wood Pellets

* Weighted average LHV (Low Heating Value) efficiency 

using data collected during EPA emissions tests in 

accordance with the requirements of CSA B415.1.

** Weighted average HHV (High Heating Value) efficiency 

using data collected during EPA emissions tests in 

accordance with the requirements of CSA B415.1.
*** A range of BTU outputs calculated using HHV 

efficiency and the burn rates from the EPA tests.

**** Based on the maximum feed rate per hour multiplied 

by approximately 8600 BTU’s which is the average BTU’s 

from a pound of pellets.

This pellet appliance needs periodic inspection and repair for proper operation. Consult the owner’s manual for further 

information. It is against federal regulations to operate this pellet appliance in a manner inconsistent with operating 

instructions in this manual.

The PS35-C is Certified to 

comply with 2020 particulate 

emission standards.

Содержание PS35-C

Страница 1: ...esult causing property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If app...

Страница 2: ...Started A Design Installation Location Considerations 5 B Thermostat Wall Control Location 6 C Tools And Supplies Needed 6 D Inspect Appliance and Components 6 E Install Checklist 7 3 Dimensions and...

Страница 3: ...ted Efficiency 68 8 EPA BTU Output 8 600 to 29 700 per hour BTU Input 12 600 to 41 900 per hour Vent Size 3 or 4 Type L or PL Hopper Capacity 45 lbs Fuel Premium Wood Pellets Weighted average LHV Low...

Страница 4: ...composed of any combination of the following Steel Plaster Brick Iron Concrete Tile Glass Slate Materials reported as passing ASTM E 136 Standard Test Method for Behavior of Metals in a Vertical Tube...

Страница 5: ...ir safe operation Do NOT install damaged incomplete or substitute components NOTICE Check building codes prior to installation Installation MUST comply with local regional state and national codes and...

Страница 6: ...the installation to ensure maximum safety and benefit Follow pipe manufacturer instructions for installation and air clearance requirements Risk of Fire Damaged parts could impair safe operation Do N...

Страница 7: ...ng this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the appliance Check...

Страница 8: ...ns Figure 8 3 Front View Figure 8 1 Top View Figure 8 2 Side View 2 1 4 in 59mm 2 1 4 in 59mm 8 7 8 in 224mm 8 7 8 in 224mm 9 1 2 in 243mm 12 1 2 in 318mm 20 1 4 in 514mm 31 3 4 in 806mm 22 1 4 in 565...

Страница 9: ...o 4 inch Offset Adapter 811 0720 Figure 9 4 Side View w Top Vent Adapter TPVNT 5 3 to 4 inch Offset Adapter 811 0720 Figure 9 1 Top View w Top Vent Adapter TPVNT 5 3 in 77mm 5 in 128mm 11 1 8 in 284mm...

Страница 10: ...2 Side View w Top Vent Adapter TPVNT 5 3 to 6 inch Offset Adapter 812 3570 Figure 10 4 Side View w Top Vent Adapter TPVNT 6 11 1 8 in 284mm 4 1 4 in 109mm 7 3 8 in 189mm 3 in 77mm 2 7 8 in 74mm 2 7 8...

Страница 11: ...Vent Adapter TPVNT 6 3 to 4 inch Offset Adapter 811 0720 Figure 11 2 Side View w Top Vent Adapter TPVNT 6 3 to 4 inch Offset Adapter 811 0720 8 7 8 in 224mm 3 1 4 in 81mm 3 1 4 in 81mm 5 1 4 in 132mm...

Страница 12: ...Back Wall to Adapter 1 25 E Side Wall to Appliance 14 356 F Back Wall to Appliance 6 1 4 159 Corner Installation Inches Millimeters G Walls to Appliance 2 51 Vertical Installation Inches Millimeters...

Страница 13: ...r protection extending beneath the flue pipe is required with horizontal venting or under the Top Vent Adapter with vertical installation Figure 13 1 Figure 13 2 Figure 13 3 Figure 13 4 C Hearth Pad R...

Страница 14: ...Depth n a n a 48 1219 D To Side Wall 14 356 n a n a All minimums listed are to a combustible surface A C B B D Table 14 1 Figure 14 2 Figure 14 1 NOTE Illustrations reflect typical installations and...

Страница 15: ...parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table below 24 in A...

Страница 16: ...d may consume the air needed for the appliance It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HVAC professional to dete...

Страница 17: ...cessful draft include Preventing negative pressure Location of appliance and chimney E Minimum Vacuum Requirements 065 inches W C F Chimney and Exhaust Connection 1 Chimney Connector Use 3 or 4 inch 7...

Страница 18: ...re 18 2 1 Locate the calculated equivalent feet of pipe on the vertical left side of the chart 2 Move to the right horizontally on the chart until you reach your altitude above sea level 3 If you fall...

Страница 19: ...D VENT The following may occur The appliance will not vent properly Smoke spillage in the house Excessive sooting CAUTION Straight Out 45 Degree NOTICE Please note that while the minimum clearance for...

Страница 20: ...tructions for all reduced air clearances installations B Vertical into Existing Class A Chimney Figure 20 3 Figure 20 2 D Through The Wall Vertical External C Vertical Interior Typical Installation PR...

Страница 21: ...T WARNING Non combustible Hearth Pad Airtight Clean out Door Sheathing 2 in 51mm Minimum Flashing 1 in 25mm Clearance 1 in 25mm Clearance with Firestop 6 in 152mm Minimum Fireclay Flue Liner with Airs...

Страница 22: ...re 22 2 1 Measure distance from floor to air vent opening in appliance and mark location on wall 2 Use a saw to cut opening in wall 2 inch kit Cut a 2 1 2 to 3 inch opening on inside wall and a 3 to 3...

Страница 23: ...et using the 2 holes already in the short horizontal pipe in the top vent adapter as a guide Install the 2 screws Figure 23 1 6 Install the vent pipe into the top vent adapter 7 To clean the top vent...

Страница 24: ...the thermostat from the mounting plate by gently pulling the two pieces apart c Slide thermostat wires through the back of the mounting plate Figure 24 3 d Connect your thermostat wire to the terminal...

Страница 25: ...UTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED Do NOT cut through Floor joist wall studs or ceiling trusses Any supporting material that would affect...

Страница 26: ...26 09 20 7058 804C A Service Maintenance Log 8 Reference Materials Date of Service Performed By Description of Service...

Страница 27: ...27 09 20 7058 804C Date of Service Performed By Description of Service...

Страница 28: ...28 09 20 7058 804C Date of Service Performed By Description of Service...

Страница 29: ...29 09 20 7058 804C Date of Service Performed By Description of Service...

Страница 30: ...Vertical Runs Only PEL DAMP3 Y Damper 4 PEL DAMP4 Outside Air Kit 3 OAK 3 Outside Air Kit 2 811 0872 Hose Alum Flex 2 Inch X 3 Ft 3 Ft SRV200 0860 Outside Air Cap Assembly 7001 044 Outside Air Collar...

Страница 31: ...it 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head Pkg of 10 25221A 10 Y Guide Pin Sleeve Pkg of 25 31120 25 Y Hurricane Screw Pkg of 40 SRV2005 861 40 Nut SER FL SMALL 1 4 20 Pkg of 24 226 0...

Страница 32: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: