MT. VERNON E2 INSERT

Following correction of any Alarm, turn the dial control to the OFF position, wait 10 seconds and turn back to 

desired setting OR unplug the unit, wait 10 seconds then restore power.

Alarm

(LED Flashing RED)

Possible Cause

Corrective Action

1 Red Flash: Empty Hopper Alarm

Hopper empty

Fill the hopper

Auger jam

Inspect the feed tube for jams

Vacuum switch not closing

Make sure fi rebox door is shut, 
vacuum hose is connected to switch 
and drop tube, wire connectors are 
connected to vacuum switch, control 
board, hopper switch, and safety 
snap disc. 

Hopper lid open

Close the hopper lid

Exhaust probe does not sense tem-
perature

Secure the exhaust probe keeping 
its wire away from hot surfaces and 
clean the exhaust plenum

Snap disc tripped

Reset snap disc

Exhaust probe not attached to 
exhaust blower properly

Secure exhaust probe to exhaust 
blower housing – keeping its wire 
away from hot surfaces

Exhaust path is dirty

Clean unit including the fi repot, 
exhaust path, and venting system

2 Red Flashes: Exhaust Probe Fail

Not connected to the control board

Connect terminal end to control board

Failed component

Replace exhaust probe – securing it 
to exhaust blower housing – keeping 
wire away from hot surfaces

4 Red Flashes: Missed Ignition

Hopper empty

Fill the hopper

Feed motor doesn’t turn

Inspect feed motor circuit (hopper lid 
must be closed, vacuum switch must 
be closed, snap disc closed, and feed 
motor must be plugged in)
Clear jam in feed tube

Dirty appliance

Clean unit including the fi repot, 
exhaust path, and venting system

Igniter has no power or is defective

Check igniter lead connections or 
replace igniter

Exhaust probe not properly installed

Secure exhaust probe to exhaust 
blower housing – keeping its wire 
away from hot surfaces

Igniter chamber plugged with debris

Clean igniter chamber

6 Red Flashes: Exhaust Blower 
Alarm

Wire from exhaust blower or encoder 
is disconnected or shorted

Make sure wire is not damaged / 
melted and ends are fully connected 
to the encoder and control board.

Defective exhaust blower

Replace exhaust blower

Defective encoder (on end of 
exhaust blower)

Replace exhaust blower

8 Red Flashes: Exhaust Over-Temp

Feed Motor Locked On

Repair wire(s) and replace control 
board 

Non-approved fuel used

Only use wood pellet fuel.  Do not 
enhance its performance with any 
other combustible substance.

Convection blower dirty

Clean impellers

Содержание MTVI-E2-CSB

Страница 1: ...Keep clothing furniture draperies and other flammable materials away WARNING CAUTION Tested and approved for wood pellets only NOTE To obtain a French translation of this manual please contact your de...

Страница 2: ...fil lectrique au dessus ou en dessous de l appareil Ne pas bloquer l espace au dessous de l appareil DANGER Il y a risque de d charge lectrique D connectez le fil lectrique de la prise de contact ava...

Страница 3: ...ety 8 B Non Combustible Materials 8 C Combustible Materials 8 D Fuel Material and Fuel Storage 8 E Before Your First Fire 9 F Filling the Hopper 9 G User Dial Control 9 H Normal Startup Sequence 9 I F...

Страница 4: ...uction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier...

Страница 5: ...T VERNON E2 INSERT WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _ q _...

Страница 6: ...pellets will feed Wait for 2 minutes If the LIGHT did not turn solid green Turn dial back to OFF Unplug appliance plug it back in and repeat Priming is only needed for first fire or starting fire on...

Страница 7: ...ies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supp...

Страница 8: ...e from sawdust or wood by products Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Stan...

Страница 9: ...happens the smoke should quickly disap pear During this stage as well as any part during the burn process the front door should not be opened HEAT SETTING HEAT SETTING O F F HI LO This startup cycle...

Страница 10: ...tial operation Curing of high temperature paint Open windows for air circulation Odors may be irritating to sensitive individuals CAUTION WARNING HOT SURFACES Glass and other surfaces are hot during o...

Страница 11: ...or in shutdown During shut down the blowers will shut off when the exhaust temperature has cooled Green 1X Stage 1 Low heat BTU Range 1 8653 19 694 Average 19 054 Green 2X Stage 2 Med Low heat BTU Ra...

Страница 12: ...r the unit may have too much air To decrease the amount of combustion air rotate the trim dial towards zero one level at a time and allow 15 minutes for stabilization prior to making another adjustmen...

Страница 13: ...manual operation of the TRANSMITTER If in the auto modes the THERMO operation will continue to operate normally To completely LOCK OUT the opera tion of the TRANSMITTER S operating signals the trans m...

Страница 14: ...the Non burn season see troubleshooting section Is there a place to lubricate the blowers to quiet them down No The most often cause of noisy blowers is from the impellers becoming dirty over time Se...

Страница 15: ...ce for your appliance Visit www quadrafire com to locate a dealer We recommend annual service by a qualified dealer A Proper Shutdown Procedure Turn dial control to OFF let appliance completely cool a...

Страница 16: ...cleaned out more often than ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of ashes should be moved outdoors immediately and placed on a non combus...

Страница 17: ...re to vacuum the back of the baffle also Inspect the drop tube and remove any residue build up in the drop tube Figure 17 3 c Assemble the crevice tool from the micro cleaning kit to attach to a Shop...

Страница 18: ...he appliance is allowed to cool b Open the front cast door and cycle the ash removal handle these should be inspected for functionality c Inspect for any degradation or deformation As the springs heat...

Страница 19: ...he glass and firebox should be inspected periodically to make sure there is a good seal If the gasket is frayed or damaged replace with a new one 8 Cleaning Exhaust System Requires No Lubrication Freq...

Страница 20: ...mation on how to handle a chimney fire In the event of a soot or creosote fire close the firebox door exit the building immediately and contact the proper fire authorities DO NOT under any circumstanc...

Страница 21: ...2 5 Rock the top of the blower slightly and lift up The blower will pass out the left side of the appliance Note You may need to loosen the surround to move it out of the way 6 Install replacement blo...

Страница 22: ...p disc is tripped Check to make sure convection blower wires are connected and reset snap disc located on RH side of appliance Clean inspect convection blower and convection air path Feed System is ja...

Страница 23: ...er fails to shut off Wire short between blower and ground Control board is defective Repair wire and replace control board Exhaust blower fails to start and or red flashes 6X indicating a exhaust enco...

Страница 24: ...t trim per trim dial instructions Feed Motor locked on Follow corrective action for feed motor not turning off Excessive fuel spilling over the fire pot and or excessive flame Dirty Appliance Clean un...

Страница 25: ...terminal end to control board Failed component Replace exhaust probe securing it to exhaust blower housing keeping wire away from hot surfaces 4 Red Flashes Missed Ignition Hopper empty Fill the hopp...

Страница 26: ...Convection Blower The convection blower is mounted at the bottom left of the appliance The convection blower pushes heated air through the heat exchange system into the room 4 Feed System The feed sy...

Страница 27: ...ON INSERT E2 Beginning Manufacturing Date Dec 2014 Ending Manufacturing Date Active Pellet Insert MTVI E2 CSB MTVI E2 MBK MTVI E2 PMH Part number list on following pages 11 13 40 39 38 37 36 35 34 33...

Страница 28: ...06P 3 Top Matte Black 7036 101MBK Porcelian Mahogany 7036 101PMH Sienna Bronze 7036 101CSB 4 Catch Clip 7036 146 5 Elbow Catch 7000 393 6 Bracket Catch 7036 145 7 Backer Side Window 414 0280 8 Side Ma...

Страница 29: ...ner 7034 136 19 2 Glass Assembly 21 W x 14 H 7034 007 Y 19 3 Hinge Female 450 2910 19 4 Door Latch Assembly 413 5200 Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y 20 Ash Pan Door 7034...

Страница 30: ...Blower SRV7080 106 Y Gasket Blower Combustion Between Housing Stove SRV7080 117 Y Gasket Motor Blower Combustion Between Housing Motor SRV7080 107 Y 32 Snap Disc L250 Manual Reset SRV230 1290 Y 33 Fl...

Страница 31: ...B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 3 Vent Adapter 3 4 811 0720 Vent Adapter 90 cleanout TPVNT 6 Vent Adapter Cleanout 811 0620 Surround Std Panel For Cast Trim SP MTVS CST Component Pac...

Страница 32: ...ille WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This produc...

Отзывы: