background image

January 

4, 

2018 

     7082-150C 

       

 

 

 

 

3

MT VERNON E2 INSERT-C

Important Safety Information

NOTE:  Hearth & Home Technologies, manufacturer of this appli

-

ance, reserves the right to alter its products, their specifications 

and/or price without notice.

Improper installation, adjustment, alteration, service or maintenance 

can cause injury or property damage. 

For assistance or additional information, consult a qualified installer, 

service agency or your dealer.

•  Installation and use of any damaged appliance. 

•  Modification of the appliance.
•  Installation  other  than  as  instructed  by  Hearth  &  Home 

Technologies.

•  Installation and/or use of any component part not approved by 

Hearth & Home Technologies.

•  Operating appliance without fully assembling all components.
•  Operating  appliance  without  legs  attached  (if  supplied  with 

appliance).

•  Do NOT Over fire - If appliance or chimney connector glows, 

you are over firing.

Any such action that may cause a fire hazard.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be 

voided by, the following actions: 

C.  Glass Specifications

This appliance is equipped with 5mm ceramic glass.  

Replace glass only with 5mm ceramic glass.  Please con-

tact your dealer for replacement glass.

Model

Mt. Vernon Insert Pellet Appliance E2

Laboratory

OMNI Test Laboratories, Inc.

Report No.

061-S-84-2

Type

Solid Fuel Room Appliance, Pellet Fuel Burn

-

ing Type

Standard

ASTM E1509-12, ULC-S628-93 and 

(UM) 

84-HUD, Mobile Home Approved.

FCC

Complies with Part 15 of FCC Rules. Opera

-

tion is subject to the following two conditions:  

(1) this device may not cause harmful inter

-

ference, and (2) this device must accept any 

interference received, including interference 

that may cause undesired  operation.

A.  Appliance Certification

NOTICE:  

This installation must conform with local codes. In the 

absence of local codes you must comply with the 

ASTM E1509-

12, ULC S628-93, (UM) 84-HUD and  ULC/ORD-C-1482. 

B.  BTU & Efficiency Specifications

D.  Electrical Rating

115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps

E.  Mobile Home Approved 

• 

This appliance is approved for mobile home installations when 

not installed in a sleeping room and when an outside combustion 

air inlet is provided.

• 

The structural integrity of the mobile home floor, ceiling, and 

walls must be maintained.  

• 

The appliance must be properly grounded to the frame of the 

mobile home and use only Listed pellet vent Class “L” or “PL” con

-

nector pipe.  

• 

Outside Air  Kit  (OAK-3)  must  be  installed  in  a  mobile  home 

installation.

F. Non-Combustible Materials

Material which will not ignite and burn, composed of any combina

-

tion of the following: 

 - 

Steel 

  - 

Plaster

 

- Brick   

 

- Iron

 - 

Concrete 

 - 

Tile

 - 

Glass 

  - 

Slate

Materials reported as passing 

ASTM E 136, Standard Test 

Method for Behavior of Metals, in a Vertical Tube Furnace of 

750° C. 

G. Combustible Materials

Material made of/or surfaced with any of the following materials: 

 

- Wood   

 

- Compressed Paper

 

- Plant Fibers 

 

- Plastic

 

- Plywood/OSB   

- Sheet Rock (drywall)

Any material that can ignite and burn: flame proofed or not, plas

-

tered or non-plastered.

 

The Quadra-Fire Mt. Vernon E2 Pellet Insert Appliance meets 

the U.S. ENVIRONMENTAL PROTECTION AGENCY 

Certified to 

comply with 2020 particulate emission standards at 0.74 G/HR EPA 

CFR subpart AAA, using ASTM E2779-10, ASTM 2515-11 Method- 
Pellet Appliance sections, CSA B415.1-10

This pellet  appliance 

needs periodic inspection and repair for proper operation. It 

is against federal regulations to operate this pellet appliance 

in a manner inconsistent with the operating instructions in 

the owner’s manual.

Emissions Report Number:

0061PS094E

EPA Certification #:

98-17

EPA Certified Emissions:

0.74 g/hr

*LHV Tested Efficiency:

83.2%

**HHV Tested Efficiency:

77.9%

***EPA BTU Output:

12,682 - 39,428 / HR

****BTU Input:

16,396 - 50,775 / HR

Vent Size: 3 or 4, “L” or “PL”

Hopper Capacity: 52 lbs.

Fuel Wood Pellets

* Weighted average LHV efficiency using data collected during 

EPA emissions test.

**

Weighted average HHV efficiency using data collected during 

EPA emissions test.

***

A range of BTU outputs based on HHV and the burn rates from 

the low and high EPA tests.

****

Based  on  the  maximum  feed  rate  per  hour  multiplied  by 

approximately  8600  BTU’s  which  is  the  average  BTU’s  from  a 

pound of pellets.

Содержание MTVI-E2-CSB-C

Страница 1: ...ot store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing...

Страница 2: ...Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearance To Combustibles US Canada 8 C Minimum Opening for Masonry Zero Clearance Fireplaces 9 D Hearth Extension 9 E Floo...

Страница 3: ...9 Amps Run 2 45 Amps E Mobile Home Approved This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided The stru...

Страница 4: ...of the appliance and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimize the use of chimney of...

Страница 5: ...on unless installing into an existing masonry fireplace B Tools And Supplies Needed C Inspect Appliance and Components Open the appliance and remove all the parts and articles packed inside the Compon...

Страница 6: ...ation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the a...

Страница 7: ...605mm 26 7 8 in 683mm 11 7 8 in 302mm 24 1 8 in 613mm 33 in 838mm 50 in 1270mm 34 1 2 in 876mm 45 in 1143mm 11 3 4 in 297mm 18 1 2 in 469mm Figure 7 2 Front View with Cast Panel Set 23 7 8 in 606mm 32...

Страница 8: ...or choice must be added to this dimension B Clearance To Combustibles US Canada Figure 8 1 Built in Appliance Rear Vent NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONL...

Страница 9: ...4 inches Minimum Opening Dimensions Inches Millimeters A Height 24 3 8 619 B Front Width Steel Panel Set 32 1 4 819 Front Width Cast Panel Set 32 1 4 819 C Back Width 24 1 8 613 D Depth Steel Panel Se...

Страница 10: ...250 2061 WARNING THIS FIREPLACE MAY HAVE BEEN ALTERED TO ACCOMMODATE AN INSERT IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE 250 2061 Heath Home Technolog...

Страница 11: ...lace was tested prior to 1998 a full height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be securely attached to the insert flue collar and t...

Страница 12: ...lk paved driveway located on public property M 12 in Under an open veranda porch deck or balcony N See Note below Electric service above below or to the side location must not obstruct or interfere wi...

Страница 13: ...demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appli ance It may be necessary to add additional ventilation...

Страница 14: ...nstruction of the structure Mechanical exhausting devices E Chimney and Exhaust Connection 1 Chimney Connector Use 3 or 4 inch 76 102mm diameter type L or PL venting system It can be vented vertically...

Страница 15: ...to the equivalent feet of pipe calculated previously and the altitude above sea level of this installation Figure 15 2 a Locate the calculated equivalent feet of pipe on the vertical left side of the...

Страница 16: ...side combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams...

Страница 17: ...Air Vertical Figure 17 1 NOTE Use metal plate around exhaust vent pipe and seal all edges with non flammable insulation such as fiberglass mineral wool or ceramic Do not use high temperature caulking...

Страница 18: ...space such as an attic or garage Figure 18 1 Collar Wire Ties Trim Ring Termination Cap 3 inch Aluminum Flex Pipe not included Figure 18 2 OAK Exploded View Lower the leveling bolts if necessary to k...

Страница 19: ...cast trim header 2 cast trim footers left and right 1 fastener package Tools Needed Powered Phillips head screw driver 1 Remove contents from box being careful not to scratch or damage the cast trim p...

Страница 20: ...crews provided Figure 20 3 Back of Top Surround Back of Side Surround Screws Figure 20 1 Shown with trim installed on panel set G Optional Log Set Placement Instructions 2 PIECE LOG SET INSTALLATION 1...

Страница 21: ...e located on an inside wall approximately 5 up from the floor W R Saturday and Sunday can be programmed individually by changing the format from 5 2 to 5 1 1 To change the format 1 Press and hold the...

Страница 22: ...ermostat should be located on an inside wall approximately 5 up from the floor PROGRAMMABLE THERMOSTAT PART WALL STAT P W R Saturday and Sunday can be programmed individually by changing the format fr...

Страница 23: ...es when burning on high A prop erly adjusted fire will burn cleaner and have higher efficiencies Please copy and paste the follow web address http www quadrafire com Owner Re sources Use and Care Vide...

Страница 24: ...4 Part Number OAK 3 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 24 1 CAUTION Never draw outsi...

Страница 25: ...January 4 2018 7082 150C 25 MT VERNON E2 INSERT C A Service and Maintenance Log Date of Service Performed By Description of Service 8 Reference Materials...

Страница 26: ...26 7082 150C January 4 2018 MT VERNON E2 INSERT C Date of Service Performed By Description of Service...

Страница 27: ...nly LOGS 60 AE B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042...

Страница 28: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Отзывы: