MT VERNON E2 INSERT-C

A.  Leveling System

The leveling bolts are located on the sides of the appliance, 

front and rear.  To access the bolts, remove the front access 

panels.  Reach in and turn the bolt to the desired height to 

level the appliance. 

Figure 18.1

B. Outside Air Kit Instructions 

Included in Kit

:  2 wire ties, 1 collar assembly, 

1 termination cap assembly, 1 trim ring, fasteners. 

3 INCH (76mm) ALUMINUM

 

FLEX PIPE NOT INCLUDED

Tools Needed:

 Phillips head screw driver; wire cutters; 

hole saw or jig saw.

1.  Measure distance from floor to air vent opening in appli

-

ance and mark location on wall.  

2.  Use saw to cut opening in wall. Cut a 3-1/2 to 4 inch 

(89-102mm) opening on inside wall and a 4 to 4-1/2 inch 

(102-114mm) opening on outside of house.

3.  Use wire ties to secure flex pipe to collar assembly.
4.  Slide trim ring over flex pipe and run pipe through wall.
5.  Attach flex pipe (not included) to outside termination cap 

with second wire tie.

6.  Secure termination cap to outside surface.
7.  Secure trim ring to interior wall.

CAUTION

Never draw outside combustion air from:

•  Wall, floor or ceiling cavity

•  Enclosed space such as an attic or garage

Figure 18.1

Collar

Wire Ties

Trim Ring

Termination Cap

3 inch Aluminum Flex

Pipe (not included)

Figure 18.2 - OAK Exploded View

Lower the leveling

bolts if necessary to

keep the insert level

when installing.

Figure 18.3

Bend tabs down.  Shipped

flat from the factory.

C.  Hearth Support

Included in Kit: 

(1) bottom, (1) trim front, (2) trim sides, (2) 

trim extensions

Tools Needed: 

 Phillips head screw driver, measuring tape, 

gloves

1. 

Remove contents from box and lay on protective surface 

to avoid scratching the paint.

2

Lay front and sides face down.  Bend the tabs down toward 

the inside.  

Figure 18.3

3. 

The side pieces are shipped flat.  It is must easier to flex the 

sides into a bowed position before installing.

4. 

Lay the cast bottom face up.  

Attach the 2 sides FIRST and 

then the front piece.

 Figure 19.1 on pg. 19

5

.  Turn the cast bottom right side up 

and attach the panel 

extensions.  Note the alignment hole.

 

6. 

Attach the appropriate footers depending on the panels & 

trim set you are installing.  The footers come in 2 sizes, 3 

and 5 inches.  Discard the footers not used.

7

.  Place  the  assembled  hearth  support  under  the  insert.  

Lower the leveling bolts if necessary to keep the insert 

level.  

8. 

Open the door and attach the hearth support to the insert.  

There are 9 attachment holes.  

Figure 19.2 on pg. 19

Appliance Set-Up

Содержание MTVI-E2-CSB-C

Страница 1: ...ot store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing...

Страница 2: ...Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearance To Combustibles US Canada 8 C Minimum Opening for Masonry Zero Clearance Fireplaces 9 D Hearth Extension 9 E Floo...

Страница 3: ...9 Amps Run 2 45 Amps E Mobile Home Approved This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided The stru...

Страница 4: ...of the appliance and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimize the use of chimney of...

Страница 5: ...on unless installing into an existing masonry fireplace B Tools And Supplies Needed C Inspect Appliance and Components Open the appliance and remove all the parts and articles packed inside the Compon...

Страница 6: ...ation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the a...

Страница 7: ...605mm 26 7 8 in 683mm 11 7 8 in 302mm 24 1 8 in 613mm 33 in 838mm 50 in 1270mm 34 1 2 in 876mm 45 in 1143mm 11 3 4 in 297mm 18 1 2 in 469mm Figure 7 2 Front View with Cast Panel Set 23 7 8 in 606mm 32...

Страница 8: ...or choice must be added to this dimension B Clearance To Combustibles US Canada Figure 8 1 Built in Appliance Rear Vent NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONL...

Страница 9: ...4 inches Minimum Opening Dimensions Inches Millimeters A Height 24 3 8 619 B Front Width Steel Panel Set 32 1 4 819 Front Width Cast Panel Set 32 1 4 819 C Back Width 24 1 8 613 D Depth Steel Panel Se...

Страница 10: ...250 2061 WARNING THIS FIREPLACE MAY HAVE BEEN ALTERED TO ACCOMMODATE AN INSERT IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE 250 2061 Heath Home Technolog...

Страница 11: ...lace was tested prior to 1998 a full height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be securely attached to the insert flue collar and t...

Страница 12: ...lk paved driveway located on public property M 12 in Under an open veranda porch deck or balcony N See Note below Electric service above below or to the side location must not obstruct or interfere wi...

Страница 13: ...demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appli ance It may be necessary to add additional ventilation...

Страница 14: ...nstruction of the structure Mechanical exhausting devices E Chimney and Exhaust Connection 1 Chimney Connector Use 3 or 4 inch 76 102mm diameter type L or PL venting system It can be vented vertically...

Страница 15: ...to the equivalent feet of pipe calculated previously and the altitude above sea level of this installation Figure 15 2 a Locate the calculated equivalent feet of pipe on the vertical left side of the...

Страница 16: ...side combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams...

Страница 17: ...Air Vertical Figure 17 1 NOTE Use metal plate around exhaust vent pipe and seal all edges with non flammable insulation such as fiberglass mineral wool or ceramic Do not use high temperature caulking...

Страница 18: ...space such as an attic or garage Figure 18 1 Collar Wire Ties Trim Ring Termination Cap 3 inch Aluminum Flex Pipe not included Figure 18 2 OAK Exploded View Lower the leveling bolts if necessary to k...

Страница 19: ...cast trim header 2 cast trim footers left and right 1 fastener package Tools Needed Powered Phillips head screw driver 1 Remove contents from box being careful not to scratch or damage the cast trim p...

Страница 20: ...crews provided Figure 20 3 Back of Top Surround Back of Side Surround Screws Figure 20 1 Shown with trim installed on panel set G Optional Log Set Placement Instructions 2 PIECE LOG SET INSTALLATION 1...

Страница 21: ...e located on an inside wall approximately 5 up from the floor W R Saturday and Sunday can be programmed individually by changing the format from 5 2 to 5 1 1 To change the format 1 Press and hold the...

Страница 22: ...ermostat should be located on an inside wall approximately 5 up from the floor PROGRAMMABLE THERMOSTAT PART WALL STAT P W R Saturday and Sunday can be programmed individually by changing the format fr...

Страница 23: ...es when burning on high A prop erly adjusted fire will burn cleaner and have higher efficiencies Please copy and paste the follow web address http www quadrafire com Owner Re sources Use and Care Vide...

Страница 24: ...4 Part Number OAK 3 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 24 1 CAUTION Never draw outsi...

Страница 25: ...January 4 2018 7082 150C 25 MT VERNON E2 INSERT C A Service and Maintenance Log Date of Service Performed By Description of Service 8 Reference Materials...

Страница 26: ...26 7082 150C January 4 2018 MT VERNON E2 INSERT C Date of Service Performed By Description of Service...

Страница 27: ...nly LOGS 60 AE B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042...

Страница 28: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Отзывы: