BLOWER AND SNAP DISC REPLACEMENT
NOTE:
BLOWER DOES NOT REQUIRE LUBRICATION. HOWEVER, WE RECOMMEND
VACUUMING OR BRUSHING OFF DUST OR LINT FROM THE FAN BLADES AS NEEDED.
This stove is equipped with a 160 cfm convection blower that is automatically controlled by a
temperature-sensing snap disc (160º). The blower has a speed control located on the control panel
in the front of the stove.
The blower is located in the pedestal. To replace or access the blower, follow the instructions
below.
1. Disconnect power from the unit and turn off gas supply.
2. Blower can be accessed either through the pedestal door in the front of the stove, or through
the rear of the stove, as shown.
3. Remove screws fastening blower to stove body.
4. Lower blower away from stove.
5. Replace in reverse order.
The snap disc can be accessed through the left side of the stove, as shown. To replace the snap disc:
1. Disconnect power from the unit and turn off gas supply.
2. Open side door to access snap disc.
3. Remove all wires attached to snap disc.
4. Remove set screw holding snap disc in place.
5. Slide snap disc up and out of holder.
6. Replace in reverse order.
IMPORTANT!
The blower is equipped with a three prong (grounding) plug for your protection
against shock hazard, and should be plugged directly into a properly grounded three prong recep-
tacle. Do not cut or remove the grounding prong from this plug.
61$3',6&
S
NAP
D
ISC
L
OCATION
%/2:(5
32:(5&25'
5($52)6729(
B
LOWER
L
OCATION
BLOWER/SNAP DISC