Grand Bay 40 Direct Vent Freestanding
Page 35
January 2000
MAINTENANCE
CLEANING AND INSPECTION
At least once yearly, preferably before the heating season, have the insert and venting system cleaned
and inspected by a qualified service person. This will ensure proper and safe operation throughout
the year.
CLEANING THE BURNER TUBES
1. Turn off pilot light.
2. Open hinged side door and unlatch spring latch.
3. Remove logs and glowing charcoals.
4. Vacuum burner compartment, especially around orifice and
primary air openings.
5. Relight pilot. Check to ensure flames are touching millivolt generator
(see diagram at right).
6. Reinstall logs. See page 11 for log installation instructions.
7.
Close front door and lock it in place with the allen screw.
8. Recheck pilot and main burner to insure they are operating correctly.
GLASS CLEANING
WARNING: DO NOT CLEAN GLASS WHEN HOT.
1. Turn off pilot.
2. Open hinged side doors and unlatch spring latches.
WARNING: DO NOT USE ABRASIVE CLEANERS
ON GLASS OR GOLD SURFACES.
3. Using regular glass cleaner, spray the glass surface and wipe with soft cloth or clean paper
towel until surface is dry.
4. Close door and tighten allen screw to prevent opening of the door while in operation.
5. Relight pilot and check main burners operation.
NOTE:
If you observe a white film on the door glass, use a hard water deposit glass cleaner or
contact your dealer.
NOTE: Do not use abrasive materials or chemical cleaners.
MAINTENANCE