background image

August 13, 2018 

 

 

 

 

7062-197G 

 

 

 

         

                  5

Explorer I

Install Guide

Getting Started

A. Design and Installation Considerations

Consideration must be given to: 

•  Safety

•  Convenience

• 

Traffic flow

•  Chimney and chimney connector required

It is a good idea to plan your installation on paper, using 

exact measurements for clearances and floor protection, 

before actually beginning the installation. If you are not 

using an existing chimney, place the appliance where there 

will be a clear passage for a factory-built listed chimney 

through the ceiling and roof.

We recommend that a qualified building inspector and 

your insurance company representative review your plans 

before and after installation.

If this appliance is in an area where children may be near 

it is recommended that you purchase a decorative barrier 

to go in front of the appliance. Remember to always keep 

children away while it is operating and do not let anyone 

operate this appliance unless they are familiar with these 

operating instructions.

Check building codes prior to installation.

• 

Installation MUST comply with local, regional, state 

and national codes and regulations.

• 

Consult insurance carrier, local building, fire officials 

or authorities having jurisdiction about restrictions, 

installation inspection, and permits.

CAUTION

 

NOTICE:

 HEARTH & HOME TECHNOLOGIES ASSUMES 

NO  RESPONSIBILITY  FOR  THE  IMPROPER 

PERFORMANCE OF THE APPLIANCE SYSTEM 

CAUSED BY:

• 

Inadequate draft due to environmental conditions

•  Down drafts

•  Tight sealing construction of the structure

•  Mechanical exhausting devices

•  Over drafting caused by excessive chimney heights

• 

Ideal performance is with height of chimney between 

14-16 feet (4.26-4.88m) measured from the base of 

the appliance.

C. Negative Pressure

Negative pressure results from the imbalance of air 

available for the appliance to operate properly. It can be 

strongest in lower levels of the house.

Causes include:

•  Exhaust fans (kitchen, bath, etc.)

•  Range hoods

•  Combustion air requirements for furnaces, water 

appliances and other combustion appliances

•  Clothes dryers

•  Location of return-air vents to furnace or air 

conditioning

• 

Imbalances of the HVAC air handling system

•  Upper level air leaks such as: 

 - Recessed lighting

 - Attic hatch

 - Duct leaks

B. Fire Safety

To provide reasonable fire safety, the following should be 

given serious consideration:

1. 

Install at least one smoke detector on each floor of 

your home to ensure your safety. They should be 

located away from the heating appliance and close 

to the sleeping areas. Follow the smoke detector 

manufacturer’s placement and installation instructions, 

and be sure to maintain regularly.  

2. 

A conveniently located Class A fire extinguisher to 

contend with small fires resulting from burning embers.

3.  A CO detector should be installed in the room with the 

appliance.

4.  A practiced evacuation plan, consisting of at least two 

escape routes.

5. 

A plan to deal with a chimney fire as follows:

In the event of a chimney fire:

a.  Evacuate the house immediately

b. 

Notify fire department.

WARNING

Asphyxiation Risk.

•  Negative pressure can cause spillage 

of combustion fumes, soot and carbon 

monoxide.

•  Appliance needs to draft properly for 

safety.

WARNING

Asphyxiation Risk.

•  Do NOT connect this appliance to a 

chimney flue servicing another appliance.

•  Do NOT connect to any air distribution duct 

or system.

May allow flue gases to enter the house.

Содержание EXPLORER I

Страница 1: ...endeur ou visitez www quadrafire com If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death WARNING Do not store or use g...

Страница 2: ...Chimney Termination Requirements 12 C 2 10 3 Rule 12 D Chimney Height Rise and Run 13 E Venting Components 13 F Chimney Systems 13 G Installing Chimney Components 15 H Proper Draft 15 5 Appliance Set...

Страница 3: ...the water in the fuel A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low and high EPA tests using Douglas Fir dimensional lumber The peak BTU out of the appliance i...

Страница 4: ...affle and other interior components NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or price without notice Improper inst...

Страница 5: ...himney heights Ideal performance is with height of chimney between 14 16 feet 4 26 4 88m measured from the base of the appliance C Negative Pressure Negative pressure results from the imbalance of air...

Страница 6: ...ing winds during the heating season Ensure adequate outdoor air for all combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vi...

Страница 7: ...iance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this check...

Страница 8: ...2 Side View with vertical flue 10 3 4 274mm 17 3 4 451mm 27 3 4 705mm 25 1 2 650mm 26 7 8 683mm Figure 8 3 Top View 3 77mm 13 3 8 342mm 1 4 7mm 3 8 12mm 25 1 2 648mm 28 5 8 728mm Figure 8 4 Side View...

Страница 9: ...pecified High temperatures or hot embers may ignite concealed combustibles Figure 9 1 Figure 9 4 Figure 9 3 Figure 9 2 Figure 9 5 Figure 9 6 Corner hearth pad dimensions with single wall pipe Corner h...

Страница 10: ...A N A 53 1 2 1359 N A DOUBLE WALL PIPE N A 8 203 24 607 11 279 N A N A 53 1 2 1359 N A For alcove only Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory b...

Страница 11: ...space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind...

Страница 12: ...or when there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 12 1 12...

Страница 13: ...isted Chimney Storm Collar Wall Support Roof Brace if required Thimble Figure 13 1 Prefabricated Exterior Chimney E Venting Components Chimney Connector It is also known as flue pipe or appliance pipe...

Страница 14: ...y Figure 14 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equivalent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm...

Страница 15: ...is must be at least 24 gauge mild steel or 26 gauge blue steel The sections must be attached to the appliance and to each other with the crimped male end pointing toward the appliance All joints inclu...

Страница 16: ...aterials from packing box 2 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air piping Use 4 inch 102mm aluminum metal flex or rigid piping to directly...

Страница 17: ...gnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for the blower and snap disc Figure 17 1 Shock Risk Do NOT remove grounding prong from plug Route cord awa...

Страница 18: ...m appliance 4 Phillips screws as shown in Figure 18 1 3 Remove rotate 180 degrees and install cast flue transition in the horizontal position as shown in Figures 18 1 and 18 2 4 Install convection shr...

Страница 19: ...ion requirements must be followed precisely 9 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure NOTE Of...

Страница 20: ...20 7062 197G August 13 2018 Explorer I Date of Service Performed By Description of Service 7 Reference Materials A Service Maintenance Log...

Страница 21: ...39 Outside Air Shield SRV33271 Y Firescreen SCR 7062 FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Screw Pan Head Phili...

Страница 22: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Отзывы: