background image

 6 

 

 

 

 

                        7062-197G 

 

 

                   August 13, 2018

Explorer I

Screws 

x4

Ash pan

Pallet 

Attach 

Bracket

Ash Pan 

Retention Bracket

1.  Remove box and 2x4 structural boards being careful 

not to damage product.

2.  Using a Phillips screw driver, remove and discard the 

4 screws and ash pan retention bracket from front of 

appliance 

(Figure 6.1)

.

3.  Remove ash pan and set aside

 (Figure 6.1)

.

4.  Remove and discard the pallet attach bracket 

(Figure 

6.1)

5.  Using a 3/8 socket or open end wrench, remove two 

bolts on back side as shown

 (Figure 6.2)

.

6.  Slide appliance forward off of pallet support brackets.

7.  Replace ash pan 

(Figure 6.1)

.

F.  Removal of Appliance from Shipping 

Materials

Figure 6.1

Bolts 

x2

Figure 6.2

D. Tools And Supplies Needed

Before beginning the installation be sure the following tools 

and building supplies are available:

Reciprocating saw

Framing material

Pliers

High temp caulking material

Hammer

Gloves

Phillips screwdriver

Framing square

•  Remove appliance and components from packaging 

and inspect for damage.

•  Report to your dealer any parts damaged in shipment.

• 

Read all the instructions before starting the 

installation. Follow these instructions carefully 

during the installation to ensure maximum safety 

and benefit.

E. Inspection of Appliance and Components

To minimize the effects of negative air pressure:

• 

Install optional outside air kit with the intake facing 

prevailing winds during the heating season

•  Ensure adequate outdoor air for all combustion 

appliances and exhaust equipment

•  Ensure furnace and air conditioning return vents are 

not located in the immediate vicinity of the appliance

•  Avoid installing the appliance near doors, walkways or 

small isolated spaces

•  Recessed lighting should be a “sealed can” design

•  Attic hatches weather stripped or sealed

•  Attic mounted duct work and air handler joints and 

seams taped or sealed

•  Basement installations should be avoided 

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be voided 

by, the following actions: 

• 

Installation and use of any damaged appliance. 

• 

Modification of the appliance.

• 

Installation other than as instructed by Hearth & 

Home Technologies.

• 

Installation and/or use of any component part not 

approved by Hearth & Home Technologies.

•  Operating appliance without fully assembling all 

components.

•  Operating appliance without legs attached (if supplied 

with appliance).

• 

Do NOT Over fire - If appliance or chimney connector 

glows, you are over firing.

Any such action that may cause a fire hazard.

Flat blade screwdriver

Electric drill and bits

Plumb line

Safety glasses

Level

Tape measure

Misc. screws and nails

7/16 socket or wrench

1/2-3/4 in. length, #6 or #8 self-drilling screws

Fire Risk.

Inspect appliance and components for damage. 

Damaged parts may impair safe operation.

•  Do NOT install damaged components.

•  Do NOT install incomplete components.

•  Do NOT install substitute components.

Report damaged parts to dealer.

WARNING

Содержание EXPLORER I

Страница 1: ...endeur ou visitez www quadrafire com If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death WARNING Do not store or use g...

Страница 2: ...Chimney Termination Requirements 12 C 2 10 3 Rule 12 D Chimney Height Rise and Run 13 E Venting Components 13 F Chimney Systems 13 G Installing Chimney Components 15 H Proper Draft 15 5 Appliance Set...

Страница 3: ...the water in the fuel A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low and high EPA tests using Douglas Fir dimensional lumber The peak BTU out of the appliance i...

Страница 4: ...affle and other interior components NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or price without notice Improper inst...

Страница 5: ...himney heights Ideal performance is with height of chimney between 14 16 feet 4 26 4 88m measured from the base of the appliance C Negative Pressure Negative pressure results from the imbalance of air...

Страница 6: ...ing winds during the heating season Ensure adequate outdoor air for all combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vi...

Страница 7: ...iance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this check...

Страница 8: ...2 Side View with vertical flue 10 3 4 274mm 17 3 4 451mm 27 3 4 705mm 25 1 2 650mm 26 7 8 683mm Figure 8 3 Top View 3 77mm 13 3 8 342mm 1 4 7mm 3 8 12mm 25 1 2 648mm 28 5 8 728mm Figure 8 4 Side View...

Страница 9: ...pecified High temperatures or hot embers may ignite concealed combustibles Figure 9 1 Figure 9 4 Figure 9 3 Figure 9 2 Figure 9 5 Figure 9 6 Corner hearth pad dimensions with single wall pipe Corner h...

Страница 10: ...A N A 53 1 2 1359 N A DOUBLE WALL PIPE N A 8 203 24 607 11 279 N A N A 53 1 2 1359 N A For alcove only Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory b...

Страница 11: ...space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind...

Страница 12: ...or when there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 12 1 12...

Страница 13: ...isted Chimney Storm Collar Wall Support Roof Brace if required Thimble Figure 13 1 Prefabricated Exterior Chimney E Venting Components Chimney Connector It is also known as flue pipe or appliance pipe...

Страница 14: ...y Figure 14 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equivalent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm...

Страница 15: ...is must be at least 24 gauge mild steel or 26 gauge blue steel The sections must be attached to the appliance and to each other with the crimped male end pointing toward the appliance All joints inclu...

Страница 16: ...aterials from packing box 2 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air piping Use 4 inch 102mm aluminum metal flex or rigid piping to directly...

Страница 17: ...gnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for the blower and snap disc Figure 17 1 Shock Risk Do NOT remove grounding prong from plug Route cord awa...

Страница 18: ...m appliance 4 Phillips screws as shown in Figure 18 1 3 Remove rotate 180 degrees and install cast flue transition in the horizontal position as shown in Figures 18 1 and 18 2 4 Install convection shr...

Страница 19: ...ion requirements must be followed precisely 9 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure NOTE Of...

Страница 20: ...20 7062 197G August 13 2018 Explorer I Date of Service Performed By Description of Service 7 Reference Materials A Service Maintenance Log...

Страница 21: ...39 Outside Air Shield SRV33271 Y Firescreen SCR 7062 FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Screw Pan Head Phili...

Страница 22: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Отзывы: