R
R
R
April 9, 2009
7051-158
Page 5
EDGE 60 Pellet Fireplace
E. Thermostat Wall Control Installation
Consideration should be given to the mounting material
when installing the wall control.
If mounting the wall control to a sheet rock surface you
should use the provided anchors for mounting.
If mounting the wall control to a wood surface or an electri
-
cal outlet box then the fasteners provided will suffice and
the anchors need not be used.
1. Remove the front cover of the wall control by prying the
cover off with a small screwdriver or your fingernail. Place
the front to the packaging to protect it from damage while
installing the sub base.
. Route the wires into the wall control leaving only the
amount necessary to make the connection to the terminal
block in the upper left hand corner remaining. The wires are
routed to the terminal block according to the letters printed
in the thermostat sub base.
Red at the top
Green in the middle
White at the bottom
. Push as much extra wire as possible back into the wall
and seal the hole in the wall with putty or insulation.
4. When re-installing the cover make sure that the wire
routing does not interfere with any of the components.
Make adjustments as needed and snap cover back into
place making sure that all locking tabs snap into place.
Red Wire
T
op
Bottom
White Wire
Green Wire
Figure 35.1- Back Side of Wall Control with
Cover Off
F. Installing Flue Collar, Vertical or Horizontal
The fireplace ships from the factory without the flue collar
and gasket attached. They are located in the component
pack inside the firebox. Follow the steps below for a vertical
or horizontal installation.
Vertical Installation
1. Remove the flue collar and gasket from the component
pack. Push out the 6 slugs in the gasket.
. Remove both the top and rear cover plates. Save screws
and plates for later re-attachment.
. Place the orange flue gasket over the locating pins on
the exhaust flue transition on the back of the fireplace.
Figure 35.2
.
4. Insert the flue pipe through the top cover plate.
5. Before inserting the flue collar into the pipe, liberally
silicone the end of the flue collar with Hi-Temp silicone
about 1-1/ inches (8mm) wide.
Figure 36.1 on page
36.
NOTE:
You will need to install one section of inch (76mm)
diameter vent pipe to clear the outer can cover plate before
installing a to 4 inch (76-10mm) pellet pipe adapter for
the balance of the venting.
6. Lay the first section of pipe on its side for screw attach
-
ment. The screws need to be directly above the locat
-
ing pins, 180 degrees apart.
Figure 36.2 on page 36.
7. Drill holes through the pipe walls directly into the flue
collar. Attach screws through pipe into flue collar.
8. Carefully feed the flue collar and pipe through the outer
can top flue opening and guide the flue collar base plate
over the locating pins. Secure with 4 screws provided
in component pack.
9. Re-attach the top cover plate to the top of the fireplace
and the rear cover to the back of the outer can.
NOTICE:
The thermostat wall control should be mounted
on an inside wall and not in direct line with the appliance
convection air.
NOTICE:
If the thermostat wall control is located too close
to the appliance, you may need to set the temperature setting
slightly higher to maintain the desired temperature in your
home.
Locating Pins
4 screws in outer corner holes
Figure 35.2- Install Orange Flue Gasket