26
June 4, 2019
7027-805C
CB1200 Pellet Insert
5
Service Parts Replacement
A. Blower Replacement
Figure 26.1
Blue Wire
White Wires
Housing Bolts
Blower Mounting
Screws
1. Combustion (Exhaust) Blower Replacement
PART NUMBER:
812-3381
b. Prep appliance from the blower removal:
iii. Disconnect the appliance from the
electrical outlet.
iv.
Remove panel set and disconnect flue.
v.
Pull appliance out onto the hearth.
vi. Remove the right-side access panel, then
slide out the right-side panel of the appliance,
held in place with 2 screws, to expose the
exhaust blower.
b. Remove existing blower (Figure 26.1):
i.
Use the 11/32” wrench or nut driver to
loosen and remove the (6) nuts holding the
motor mount plate to the blower housing on
your appliance.
ii. Remove the washer from beneath the terminal
ring on the grounding wire.
iii.
Pull motor/mounting plate from blower housing.
iv.
Scrape off the old gasket material from
blower housing.
c. Install new blower:
i. The blower and blower housing is shipped as a
appliance in this kit. It is necessary to separate
them at this point.
ii.
Use 11/32” wrench or nut driver to loosen and
remove the (6) nuts holding the motor mount
plate to the blower housing.
iii. Remove the washer from beneath the terminal
ring on the grounding wire.
iv.
Pull motor/mounting plate from blower housing
and discard or set aside the blower housing.
v. Carefully remove gasket from new housing and
set onto the appliance blower housing.
d. Reinstall blower to blower housing:
i. Install blower on housing ensuring that wiring
exits facing the 8 o’clock position for the
CB1200 appliance and 12 o’clock for the 1200-
I insert. Place washer and then grounding wire
on nearest mounting plate stud.
ii. Use nuts removed in step A1 to secure blower
to housing.
iii. Reconnect wiring. Use Jumper wire if
necessary. Reconnect power supply.
d. Re-install appliance:
i. Reassemble right side panel to appliance with
2 screws previously removed.
ii.
Push appliance back into the hearth.
iii.
Reconnect flue and re-install panel set; plug in
appliance to electrical outlet.
2. Convection Blower Replacement
PART NUMBER:
812-4900
a. The blower is located at the bottom rear of the
insert. If an outside air kit is also installed, you
will first need to remove the outside air flange
by removing the 2 screws using a Phillips head
screwdriver. You do not need to remove the flex
pipe from the flange.
b.
Remove panel set and disconnect flue.
c.
Pull appliance out onto the hearth.
d. Remove left access panel and then slide out left
side panel of appliance to expose the convection
blower. Loosen wing nut on the vacuum switch and
remove vacuum switch to allow room to remove
the blower.
e. Disconnect the wires from the blower. The wires
coming from the wiring harness are purple & white
and the wires from the blower are black.
f. The blower is held in place with a magnet. A
wing nut and plate are installed at the factory for
shipping purposes only. This can be removed once
the appliance is installed. Lift up blower from the
magnet and remove.
g. Re-install in reverse order.
Shock Risk
.
•
Do NOT remove grounding prong
from plug.
•
Plug directly into properly grounded 3
prong receptacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front
of appliance.
CAUTION