August
1,
2018
7014-285C
9
CB1200 Pellet Insert
B. Clearance To Combustibles, UL and ULC
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY
.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
Be sure to follow vent manufacturers clearance
to combustibles.
*If interior of chase will be drywalled, add the
thickness to this measurement.
**From finished floor protection. The size of your
floor protector choice must be added to this
dimension. If using Quadra-Fire floor protector,
Part 811-0730, allow 1-1/2 inches (38mm).
25 in**
(635mm)
25 in**
(635mm)
29-3/4 in.
(756mm)
15-1/2 in*
(394mm)
Figure 9.1
NOTE
: A Quadra-Fire floor protector (Part 811-0730) is available through your dealer to be used as a
floor protector for the section under the insert body only. Floor protection to front and sides of
insert appliance must be supplied in addition to this part.
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
WARNING