10
7014-285C
August
1,
2018
CB1200 Pellet Insert
C
D
A
B
C. Minimum Opening for Masonry
& Zero Clearance Fireplaces
Figure 10.1
Figure 10.2
SIDE
TRIM
HEARTH
EXTENSION
28-1/2 in
(724mm)
SIDE
W
ALL
TOP TRIM
19-3/4 in
(502mm)
19-3/4 in
(502m)
18-1/4 in
(464mm)
Figure 10.3
FIREPLA
CE FR
ONT SURF
ACE
MANTEL
USA & CANADA
17 in (432mm)
37-1/2 in
(952mm)
12 in
max *
16
(406mm)
NOTE:
Minimum opening dimensions include a 1/4” (6mm)
clearance around appliance.
Note:
If trim measurement is over 3/4 in (19mm) in depth
use mantle or side clearances to combustibles.
Location
Inches
Millimeters
A
Height
(Maximum Hopper Adjustment)
*
22-1/4
565
Height
(Minimum Hopper Adjustment)
*
19-3/4
502
B Front Width
29-3/4
756
C Rear Width
22-1/2
572
D Depth
13-1/4
337
*Height:
The Classic Bay 1200 Insert has the option of
an adjustable hopper from 22 inches for the maximum
to 19-1/2 inches for the minimum. Add a 1/4 inch to the
adjustment for clearances for any measurement in between
the maximum and the minimum height. The Maximum and
minimum are already calculated for you in the above table
for convenience.
D. Hearth Extension
Use a Type II non-combustible floor protector, extending
beneath the appliance and to the front, and to the sides as
indicated in sub-section
E. Floor Protection on page 11
.
The floor must be non-combustible or otherwise adequately
protected from radiant heat given off by the appliance and
from sparks and falling embers. A layer of thin brick or
ceramic tile over a combustible floor is not sufficient.
WARNING
Fire Risk.
Hearth pads must be installed exactly as specified.
High temperatures or hot embers may ignite
concealed combustibles.