8
7022-514C
July 7, 2015
CASTILE INSERT
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
WARNING
Failure to comply may cause house fi re.
NOTE:
•
Illustrations
refl ect typical installations and
are FOR DESIGN PURPOSES ONLY.
•
I
llustrations/diagrams are not drawn to
scale.
•
Actual installation may vary due to
individual design preference.
B. Clearance To Combustibles, UL and ULC
Inches
Millimeters
A
Top of Hopper
Top Vent
2.0
51
Rear Vent
2.5
64
B
Side of Hopper
Top or Rear Vent
2.0
51
C
Back of Hopper
Top or Rear Vent
4.0
102
D
Vent Pipe to Combustible
Top or Rear Vent
3.0
76
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Optional Outside Air
Figure 8.1
Figure 8.2
AS A BUILT-IN
A
C
B
D
C
B
0 in. Clearance To Exposed Section And Face Trim
12 in
305mm
Combustible
Mantel
6 in
152mm
Outside Air
Top Vent:
2 in
51mm
Rear Vent:
2.5 in
64mm
Back of Hopper:
4in
102mm
Vent Pipe to
Combustibles:
3 in
76mm
Содержание CASTILEI-CSB