May 12, 2017
7021-154J
15
CASTILE FREESTANDING
Straight Out
Figure 15.1
Figure 15.2
45 Degree
Wall
Thimble
Illustration shows venting going in both directions.
Choose which one is best for your installation.
2 in. (51mm)
Minimum
2 in.
(51mm)
Minimum
6 in. (152mm)
Minimum
6 in.
(152mm)
Minimum
6 in.
(152mm)
Minimum
Non-combustible Hearth Pad
Wall
Thimble
Horizontal
Termination
Cap
2 in.
(51mm)
Minimum
6 in.
(152mm)
Minimum
From Glass
A. Through The Wall
Horizontal termination cap must be a minimum of 6 inches.
(152mm) from the wall. Approved for mobile home installa
-
tions. Must use 3 or 4 inch (76-102mm) “L” or “PL” Listed
pellet venting or Listed double wall pipe and a Quadra-Fire
Outside Air Kit in mobile homes.
NOTE:
In Canada, where passage through a wall or partition of com
-
bustible construction is desired, the installation shall conform to
CAN/CSA-B365
NOTICE:
Please note that while the minimum clearance for the ter
-
mination cap is 6 inches (152mm) there is the possibility
of soot build-up around the termination area. If this occurs
we suggest to move the termination further away from the
house to prevent it.
We strongly recommend that you DO NOT DOWN
-
WARD VENT.
The following may occur:
• The appliance will not vent properly
• Smoke spillage in the house
• Excessive sooting
CAUTION
5
Venting Systems