CASTILE FREESTANDING

To minimize the effects of negative air pressure:
•  Install the outside air kit with the intake facing prevailing 

winds during the heating season

•  Ensure adequate outdoor air for 

all

 combustion appliances 

and exhaust equipment

•  Ensure furnace and air conditioning return vents are not 

located in the immediate vicinity of the appliance

•  Avoid  installing  the  appliance  near  doors,  walkways  or 

small isolated spaces

•  Recessed lighting should be a “sealed can” design
•  Attic hatches weather stripped or sealed
•  Attic mounted duct work and air handler joints and seams 

taped or sealed

D.  Draft 

Draft is the pressure difference needed to vent an appli

-

ance successfully. When an appliance is drafting suc

-

cessfully, all combustion byproducts are exiting the home 

through the chimney.

Install through the warm airspace enclosed by the build

-

ing envelope. This helps to produce more draft, especially 

during lighting and die-down of the fire.

Considerations for successful draft include:

•  Preventing negative pressure

•  Location of appliance and chimney

E.  Chimney and Exhaust Connection 

NOTICE: 

Hearth  &  Home  Technologies  assumes  no 

responsibility for the improper performance of the chimney 

system caused by:

• 

Inadequate draft due to environmental conditions

• 

Down drafts

• 

Tight sealing construction of the structure

• 

Mechanical exhausting devices

6.  DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENT

-

ING SYSTEM OF THIS Appliance.

7.  DO  NOT  CONNECT THIS Appliance TO A  CHIMNEY  FLUE 

SERVING ANOTHER APPLIANCE.

NOTE:  All pipe must be welded seam pipe whenever possible.  

Seal pipe joints with high temperature silicone (500°F [260°C] 

minimum rated only).

F.  Venting Termination Requirements

1

Termination must exhaust above air inlet elevation. 

 It is 

strongly recommended that at least 60 inches (1.5m) 

of vertical pipe be installed when appliance is vented 

directly through a wall.

  This will create a natural draft, 

which will help prevent the possibility of smoke or odor 

venting into the home during a power outage.  It will also 

keep  exhaust  from  causing  a  nuisance  or  hazard  by 

exposing people or shrubs to high temperatures.  The 

safest and preferred venting method is to extend the vent 

vertically through the roof.

2

Distance from

 

doors and opening windows, or gravity or 

ventilation air inlets into building:

a.  Not less than 48 inches (1.2m) below;
b.  Not less than 48 inches (1.2m) horizontally from;
c.  Not less than 12 inches (305mm) above.

3

Distance from permanently closed windows;

 a.  Not less than 12 inches (305mm) below; horizontally 

from or above.

4

Distance between

 

bottom of termination and grade should 

be 12 inches (305mm) minimum.  This is conditional upon 

plants in the area, and nature of grade surface.  The grade 

surface must be a non-combustible material (i.e., rock, 

dirt).   The  grade  surface  must  not  be  lawn.    Distance 

between bottom of termination and public walkway should 

be 7 feet (2.13m) minimum.

5

Distance  to  combustible

 

materials  must  be  24  inches 

(610mm)  minimum.   This  includes  adjacent  buildings, 

fences, protruding parts of the structure, roof overhang, 

plants and shrubs, etc.

6.  Termination Cap Location (Home Electrical Service)

•  Side-to-side clearance is to be the same as minimum 

clearance to vinyl inside corners.

•  Clearance of a termination cap below electrical service 

shall be the same as minimum clearance to vinyl soffits.

•  Clearance of a termination cap above electrical service 

will be 12 inches (305mm) minimum.

•  Location of the vent termination must not obstruct or 

interfere with access to the electrical service.

Do not terminate vent

 in any enclosed or semi-enclosed 

area such as a carport, garage, attic, crawl space, under a 

sun deck or porch, narrow walkway or closely fenced area, or 

any location that can build up a concentration of fumes such 

as a stairwell, covered breezeway, etc.

CAUTION

NOTE

: The appliance exhaust outlet is designed to accom

-

modate 3 inch venting. Use of 4 inch venting requires the 

use of a 3-to-4 inch exhaust vent increaser in addition to 

any other  venting components needed, sold separately.

1.

 

Chimney & Connector

:  Use 3 or 4 inch (76-102mm)  diameter 

type “L” or “PL” venting system.  It can be vented vertically or 
horizontally.

2.

  Mobile Home: 

Approved for all Listed pellet vent.  If using the 

3 inch (76mm) vertical Top Vent Adapter Kit or the 3 to 6 inch 
(76-152mm) Top  Vent  Offset Adapter,  use  Listed  double  wall 
flue connector.  A Quadra-Fire Outside Air Kit must be used with 
manufactured home installations.

3.

  Residential: 

 The 3 inch (76mm) vertical Top Vent Adapter Kit and 

the 3 to 6 inch (76-152mm) Top Vent Offset Adapter are tested 
to use 24 gauge single wall flue connector or Listed double wall 
flue connector to Class A Listed metal chimneys, or masonry 
chimneys meeting International Residential Code standards for 
solid fuel appliances.

4.

  INSTALL VENT AT CLEARANCES SPECIFIED BY THE 

VENT MANUFACTURER.

5

.  Secure exhaust venting system to the appliance with at least 

3 screws.  Also secure all connector pipe joints with at least 3 
screws through each joint.

Содержание CASTILE-MBK-B

Страница 1: ...minimum clearances to combustibles as specified Failure to comply may cause house fire HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns Do not to...

Страница 2: ...Components 5 E Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearances to Combustibles UL and ULC 8 C Hearth Pad Requirements UL and ULC 8 D Alcove 9 4 Vent Informatio...

Страница 3: ...ped with 5mm ceramic glass Replace glass only with 5mm ceramic glass Please con tact your dealer for replacement glass D Electrical Rating 115 VAC 60 Hz Start 4 1 Amps Run 1 1 Amps E Mobile Home Appro...

Страница 4: ...the installation Location of the appliance and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to mini...

Страница 5: ...ermostat Wall Control Location The thermostat wall control s location will have some affect on the appliance s operation Maximum wire length from appliance is 100 feet 30 48m with continuous non splic...

Страница 6: ...the party responsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the...

Страница 7: ...7 3 Side View Figure 7 4 Side View with Top Vent Adapter 24 in 609mm 24 5 8 in 626mm 12 in 305mm 24 in 609mm 28 9 16 in 725mm 15 15 16 in 405mm 22 7 8 in 582mm 17 in 431mm 16 5 16 in 414mm 28 3 4 in...

Страница 8: ...ecommended extending beneath the flue pipe when installed with horizontal venting or under the Top Vent Adapter with vertical installation CANADA INSTALLATIONS A non combustible floor pro tection exte...

Страница 9: ...Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference D Alcove Figure 9 1 All minimums listed are to a combustible surface Minimum Maximum Inc...

Страница 10: ...protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table be...

Страница 11: ...t with your local HVAC professional to determine the ventilation demands for your house Vent Configurations To reduce probability of reverse drafting during shut down conditions Hearth Home Technologi...

Страница 12: ...zontally from c Not less than 12 inches 305mm above 3 Distance from permanently closed windows a Not less than 12 inches 305mm below horizontally from or above 4 Distance between bottom of termination...

Страница 13: ...2 If the equivalent length of pipe is 12 feet 3 7m with altitude of 6 000 feet 1829m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent H Pipe Selection Chart The chart will help you in de...

Страница 14: ...cumulate ash and will need to be cleaned more often Try to keep them as short as possible ONE 90 ELBOW Total Horizontal Minimum Vertical Vent Diameter 4 0 3 5 5 3 6 6 3 7 7 3 8 8 4 9 9 4 10 10 4 11 11...

Страница 15: ...stalla tions Must use 3 or 4 inch 76 102mm L or PL Listed pellet venting or Listed double wall pipe and a Quadra Fire Outside Air Kit in mobile homes NOTE In Canada where passage through a wall or par...

Страница 16: ...an out Cover 24 in 610mm Minimum Ceiling Support 6 in 152mm Flue Connector 6 in 152mm Class A Chimney Connector Adapter 3 in to 6 in 76 152mm Top Vent Kit We recommend a minimum of 60 inches 1524mm ve...

Страница 17: ...ce Concrete Cap 1 in 25mm clearance with firestop 6 in 152mm minimum Non combustible Hearth Pad Airtight clean out door Sheathing 2 in 51mm minimum Flashing 1 in 25mm clearance 1 in 25mm clearance wit...

Страница 18: ...N Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage Flex Hose Hose Clamp Collar Assembly Trim Ring Termination Cap Assembly Hose Clamp Air I...

Страница 19: ...hort horizontal pipe in the top vent adapter as a guide Install the 4 screws Figure 19 2 6 Install the vent pipe into the top vent adapter be sure to silicone all joints C Rear Vent Rear Vent to Top V...

Страница 20: ...from appliance Do NOT route cord under or in front of appliance CAUTION The appliance comes standard with a wall thermostat and 25 of wire If you need to run more than 25 make sure you use a continuo...

Страница 21: ...S FOR THERMOSTAT WIRES POWER OUTLET FUSE Fuse W R Figure 21 2 Press and pull to remove Press and pull to remove Figure 21 3 Thermostat Operation Digital display Digital display Back light Heat On or O...

Страница 22: ...3280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 22 1 CAUTION Never draw outside combustion ai...

Страница 23: ...ssembly 7001 044 Outside Air Collar Assembly SRV7001 045 Trim Plate Outside Air Kit 412 7100 Pullrod Handle PULLROD HNDL Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y...

Страница 24: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deale...

Отзывы: