background image

SAVE THESE INSTRUCTIONS

www.quadrafire.com  

This manual contains instructions for Installation, Operation & Maintenance.

Please read this entire manual before you install and use your new room heater.  Failure to follow 

instructions may result in property damage, bodily injury, or even death.

Isle Royale

Non-Catalytic, Top-load, Wood Heater

O-T L

Tested and 

Listed by

Beaverton

Oregon USA

OMNI-Test Laboratories, Inc.

C

250-5763B     February 4, 2005

PRIOR TO FIRST FIRE:  Remove all labels from glass.  Clean plated surfaces with a glass cleanser and soft 

cloth to prevent staining from fingerprint oils.

IMPORTANT SAFETY NOTES:

  1) When  installing  your  stove,  particular  attention  should  be  paid  to  fire  protection.    If  this  room  heater  is  not 

properly installed, a house fire may result.  To reduce the risk of fire, follow the installation instructions.  Contact 

local  building  or  fire  officials  or  authority  having  jurisdiction  about  restrictions,  installation  inspection  and 

permit requirements in your area.

  2) CAUTION:  Never use gasoline or gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to 

start or “freshen up” a fire in this heater.  Keep all such liquids well away from heater while it is in use.

  3) During operation, if any part of the stove starts to glow, the stove is in an overfired condition.  Close the air controls 

completely until the glowing has stopped.  

OVERFIRING VOIDS YOUR WARRANTY!

  4) Cool ashes should be disposed of carefully, using a metal container.

  5) Do not burn wet or green wood.  Store wood in a dry location.

  6) 

DO  NOT  BURN  GARBAGE  OR  FLAMMABLE  FLUIDS  SUCH AS  GASOLINE,  NAPHTHA  OR  ENGINE 

OIL. 

  Do  not  burn  treated  wood,  or  wood  with  salt  (driftwood,  etc.).    Burning  materials  other  than  wood 

(including  charcoal)  under  adverse  conditions  may  generate  carbon  monoxide  in  the  home,  resulting  in 

illness or possible death.

  7) Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.

  8) Check  your  chimney  system  thoroughly  when  installing  into  an  existing  metal  or  masonry  chimney.    Seek 

professional advice if in doubt about its condition.

  9) Do not connect this unit to a chimney flue already serving another appliance.

10) Comply with all minimum clearances to combustibles as shown in this manual for this appliance.

11)  Build fire on brick firebox floor.  Do not use grates, andirons or other methods to support fuel.

12) 

HOT WHILE IN OPERATION! 

 Keep children, pets, clothing and furniture away.  Contact can cause skin burns.

13) Do not connect to any air distribution duct or system

14) 

RISK OF FIRE! 

 Do not operate with stove door open, without the firescreen, or ash removal system door open.

15) For further information refer to NFPA 211 (USA) or CAN/CSA-B365 (Canada).

16) Do not operate without fully assembling all components.  Burning your stove without the legs attached (if supplied 

with unit) will void your warranty, and could present a serious safety hazard

17) Do not oeprate with broken glass..

1445 North Highway

Colville, WA  99114-2008

R

Содержание Isle Royale

Страница 1: ...YOUR WARRANTY 4 Cool ashes should be disposed of carefully using a metal container 5 Do not burn wet or green wood Store wood in a dry location 6 DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLI...

Страница 2: ...DE L INSTALLATION LE CONTACT PEUT CAUSER DES BR LURES LA PEAU GARDEZ LES MEUBLES ET LES MAT RIAUX COMBUSTIBLES LOIN DE L ESPACE D SIGN DE L APPAREIL VOIR L TIQUETTE ET LES INSTRUCTIONS ESPACES LIBRES...

Страница 3: ...Plated Surfaces 22 Brick replacement 23 Door gasket 23 Exploded view 24 Accessories Service Part 25 Service Maintenance Log 26 Warranty 27 Contact Information 28 TABLE OF CONTENTS PRE USE CHECK LIST...

Страница 4: ...ove to the chimney see page 10 It must be 6 inch 152mm minimum diameter 24 MSG black or blued steel or an approved air insulated double wall venting pipe THIMBLE A manufactured or site constructed dev...

Страница 5: ...x inch 6 152mm diameter listed double wall air insulated connector pipe with listed factory built UL103 HT Class A chimney or a masonry chimney Mobile Home must be equipped with a spark arrestor and t...

Страница 6: ...FIREPLACE OR THROUGH THE WALL Six inch 6 152mm diameter listed double wall air insulated connector pipe with UL 103HT listed factory built Class A chimney or a masonry chimney Mobile Home must be equi...

Страница 7: ...DA 203mm 8 203mm 8 203mm 8 457mm 18 1251mm 49 1 4 Minimum 1137mm 44 3 4 Minimum 16 from glass std legs 8 USA Fuel loading door 36 3 4 Minimum 39 1 4 Minimum 18 from glass hearth legs WHEN LOCATING YOU...

Страница 8: ...f temperature difference from one side of the material to the other The LOWER the k factor means less heat is being conducted through the non combustible material to the combustible material beneath i...

Страница 9: ...t the other two and thus change the amount of draft in the entire system A source of air oxygen is necessary in order for combustion to take place The combustion air enters the rebox below the ash cat...

Страница 10: ...ire Protection Association NFPA Standard 211 It must have at least a 5 8 inch 16mm re clay liner or a listed chimney liner system See Figure 10B Make sure there are no cracks loose mortar or other sig...

Страница 11: ...nd combustible wall and 2 the 1 inch 25mm air space around the chimney connector as it passes through the chimney section to the chimney The location of the opening through the wall to the chimney mus...

Страница 12: ...inst the chimney Install the trim collar on the outside of the opening Check to ensure there is a 1 inch 25mm air space between the connector and the chimney section During installation ensure that a...

Страница 13: ...should t tightly and be sealed with high temperature furnace cement unless the kit s instructions state otherwise Figure 13 The tight tting installation aids the proper draw of the chimney Figure 13A...

Страница 14: ...purchase but they demonstrate the basic components necessary for a proper and safe installation The chimney must be the required height above the roof or other obstruction for safety and for proper d...

Страница 15: ...cted to a 6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS Floor protection referenced on page 7 must be followed 8 Use silicone to create an effective...

Страница 16: ...ion of the outside air kit rst NOTE If using Hearth Legs you can install an Outside Air Kit or Blower but not both 1 Remove 3 Phillips head screws from rear of unit 2 Using the Phillips head screws at...

Страница 17: ...d and not allowed to go out This will ensure the cleanest possible re If you are adjusting your stove for a low burn rate you should close down the air to the point where you can still maintain some a...

Страница 18: ...ate settings and will vary with type of wood or chimney draft Due to altitude and other environmental circumstances this operation infor mation is a guideline only Similar burn rates may be obtained u...

Страница 19: ...s 3 inches 76mm or 4 inches 102mm in diameter Be careful not to smother the re Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequa...

Страница 20: ...e blower off until your stove is hot and a good coalbed is established The blower may be turned on approximately 30 minutes after a good coalbed is established 2 High burn setting The blower may be le...

Страница 21: ...steps to ensure that the accumulation of ash and creosote falls directly into the rebox for removal MAINTENANCE ASH REMOVAL DISPOSAL The stove is equipped with an ash removal system We recommend empt...

Страница 22: ...ss This air ow washes the glass helping to keep smoke from adher ing to its surface When operated at a low burn rate less air will be owing over the glass and the smokey relatively cool condition of a...

Страница 23: ...is available from your dealer MAINTENANCE Ensure that the rebricks are correctly positioned as referenced by diagram below and that the rebox does not contain any broken brick prior to operating the u...

Страница 24: ...sembly 13 Griddle Handle 23 Rear Shield 4 Brick Assembly 14 Hopper Lid Stop 24 Side Tertiary Channel Right 5 Door Assembly 15 Manifold Tube 4 25 Side Left 6 Face Assembly 16 Primary Air Channel 26 Sid...

Страница 25: ...Tube Set 4 832 3360 Accessories Serial No Part No Blower 831 1701 Brackets with Mitten Rod Gold WSB2G 2 844 7980 Brackets with Mitten Rod Black WSB2 2 844 7970 Firescreen USA installations only 834 3...

Страница 26: ...R Page 26 February 4 2005 Isle Royale Wood Stove 250 5763B Date of Service Performed By Description of Service Service and Maintenance Log...

Страница 27: ...ears for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items...

Страница 28: ...0481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 D320652 D445174 D462436 Canada 1297749 2195264 2225408 or other...

Отзывы: