250-5763B

First, make the frame for the thimble, ensuring it 

is no smaller than 14 inches (356mm) square to 

maintain  a  2  inch  (51mm)  air  space  around  the 

chimney section.  

Attach the wall spacer to the chimney side of the 

frame.  Then insert the frame into the opening, toe 

nailing it to the wall studs.  Install the wall band in the 

framing to secure the chimney section in place.  

Insert a single section of chimney connector into the 

chimney through the wall band, being sure it does 

not protrude into the chimney beyond the edge of 

the chimney flue lining.  

Apply high temperature furnace cement to the end 

of the chimney section and install it over the con-

nector, through the wall spacer.  Tighten the wall 

band to hold the chimney section firmly in place and 

against the chimney.  

Install the trim collar on the outside of the opening.  

Check to ensure there is a 1 inch (25mm) air space 

between the connector and the chimney section.  

During installation ensure that a 2 inch (51mm) air 

space to the wood framing is maintained.  Do not 

fill this space with insulation.  Insulation in this air 

space will cause a heat buildup which may ignite 

the wood framing.

SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE (CONT'D)

Chimney Flue Liner

Fireclay 

Liner or 

Equivalent

Masonry Chimney 

Constructed to NFPA 211

Wall Spacer

Wall Band

Trim Collar

Chimney

 Connector

1" (25mm) Air Space 

to Chimney Section

Min. Clearance 

2" (51mm)

Min. Chimney Clearance 

to Wall Spacer and 

Combustibles - 2" (51mm)

Chimney Section

Trim Collar

Chimney Section 

with 2" (51mm) 

Clearance to 

Combustibles

Chimney 

Connector

Fire Clay 

Flue Liner

with Airspace

Masonry

 Chimney

Wall Band to 

Secure Chimney 

Section

Wood Studs Used for 

Framing - Spaced 2" 

(51mm) clearance from 

Masonry Chimney

Wall Spacer

Figure 12A

Figure 12B

Содержание Isle Royale

Страница 1: ...YOUR WARRANTY 4 Cool ashes should be disposed of carefully using a metal container 5 Do not burn wet or green wood Store wood in a dry location 6 DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLI...

Страница 2: ...DE L INSTALLATION LE CONTACT PEUT CAUSER DES BR LURES LA PEAU GARDEZ LES MEUBLES ET LES MAT RIAUX COMBUSTIBLES LOIN DE L ESPACE D SIGN DE L APPAREIL VOIR L TIQUETTE ET LES INSTRUCTIONS ESPACES LIBRES...

Страница 3: ...Plated Surfaces 22 Brick replacement 23 Door gasket 23 Exploded view 24 Accessories Service Part 25 Service Maintenance Log 26 Warranty 27 Contact Information 28 TABLE OF CONTENTS PRE USE CHECK LIST...

Страница 4: ...ove to the chimney see page 10 It must be 6 inch 152mm minimum diameter 24 MSG black or blued steel or an approved air insulated double wall venting pipe THIMBLE A manufactured or site constructed dev...

Страница 5: ...x inch 6 152mm diameter listed double wall air insulated connector pipe with listed factory built UL103 HT Class A chimney or a masonry chimney Mobile Home must be equipped with a spark arrestor and t...

Страница 6: ...FIREPLACE OR THROUGH THE WALL Six inch 6 152mm diameter listed double wall air insulated connector pipe with UL 103HT listed factory built Class A chimney or a masonry chimney Mobile Home must be equi...

Страница 7: ...DA 203mm 8 203mm 8 203mm 8 457mm 18 1251mm 49 1 4 Minimum 1137mm 44 3 4 Minimum 16 from glass std legs 8 USA Fuel loading door 36 3 4 Minimum 39 1 4 Minimum 18 from glass hearth legs WHEN LOCATING YOU...

Страница 8: ...f temperature difference from one side of the material to the other The LOWER the k factor means less heat is being conducted through the non combustible material to the combustible material beneath i...

Страница 9: ...t the other two and thus change the amount of draft in the entire system A source of air oxygen is necessary in order for combustion to take place The combustion air enters the rebox below the ash cat...

Страница 10: ...ire Protection Association NFPA Standard 211 It must have at least a 5 8 inch 16mm re clay liner or a listed chimney liner system See Figure 10B Make sure there are no cracks loose mortar or other sig...

Страница 11: ...nd combustible wall and 2 the 1 inch 25mm air space around the chimney connector as it passes through the chimney section to the chimney The location of the opening through the wall to the chimney mus...

Страница 12: ...inst the chimney Install the trim collar on the outside of the opening Check to ensure there is a 1 inch 25mm air space between the connector and the chimney section During installation ensure that a...

Страница 13: ...should t tightly and be sealed with high temperature furnace cement unless the kit s instructions state otherwise Figure 13 The tight tting installation aids the proper draw of the chimney Figure 13A...

Страница 14: ...purchase but they demonstrate the basic components necessary for a proper and safe installation The chimney must be the required height above the roof or other obstruction for safety and for proper d...

Страница 15: ...cted to a 6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS Floor protection referenced on page 7 must be followed 8 Use silicone to create an effective...

Страница 16: ...ion of the outside air kit rst NOTE If using Hearth Legs you can install an Outside Air Kit or Blower but not both 1 Remove 3 Phillips head screws from rear of unit 2 Using the Phillips head screws at...

Страница 17: ...d and not allowed to go out This will ensure the cleanest possible re If you are adjusting your stove for a low burn rate you should close down the air to the point where you can still maintain some a...

Страница 18: ...ate settings and will vary with type of wood or chimney draft Due to altitude and other environmental circumstances this operation infor mation is a guideline only Similar burn rates may be obtained u...

Страница 19: ...s 3 inches 76mm or 4 inches 102mm in diameter Be careful not to smother the re Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequa...

Страница 20: ...e blower off until your stove is hot and a good coalbed is established The blower may be turned on approximately 30 minutes after a good coalbed is established 2 High burn setting The blower may be le...

Страница 21: ...steps to ensure that the accumulation of ash and creosote falls directly into the rebox for removal MAINTENANCE ASH REMOVAL DISPOSAL The stove is equipped with an ash removal system We recommend empt...

Страница 22: ...ss This air ow washes the glass helping to keep smoke from adher ing to its surface When operated at a low burn rate less air will be owing over the glass and the smokey relatively cool condition of a...

Страница 23: ...is available from your dealer MAINTENANCE Ensure that the rebricks are correctly positioned as referenced by diagram below and that the rebox does not contain any broken brick prior to operating the u...

Страница 24: ...sembly 13 Griddle Handle 23 Rear Shield 4 Brick Assembly 14 Hopper Lid Stop 24 Side Tertiary Channel Right 5 Door Assembly 15 Manifold Tube 4 25 Side Left 6 Face Assembly 16 Primary Air Channel 26 Sid...

Страница 25: ...Tube Set 4 832 3360 Accessories Serial No Part No Blower 831 1701 Brackets with Mitten Rod Gold WSB2G 2 844 7980 Brackets with Mitten Rod Black WSB2 2 844 7970 Firescreen USA installations only 834 3...

Страница 26: ...R Page 26 February 4 2005 Isle Royale Wood Stove 250 5763B Date of Service Performed By Description of Service Service and Maintenance Log...

Страница 27: ...ears for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items...

Страница 28: ...0481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 D320652 D445174 D462436 Canada 1297749 2195264 2225408 or other...

Отзывы: