February 4, 2005

Isle Royale Wood Stove

250-5763B

LISTINGS and SAFETY NOTICES

WARNING !

  

DO NOT ATTEMPT TO OPERATE THIS WOODSTOVE 

WITHOUT  READING AND  UNDERSTANDING  THESE  OPERATING 

INSTRUCTIONS  THOROUGHLY.    FAILURE  TO  OPERATE  THIS 

APPLIANCE PROPERLY MAY CAUSE A HOUSE FIRE.

WARNING !  THE OUTSIDE SURFACES OF THIS UNIT WILL BECOME 

EXTREMELY HOT DURING USE.  ALWAYS KEEP CHILDREN AWAY 

WHILE IT IS OPERATING AND DO NOT LET ANYONE OPERATE 

THIS APPLIANCE  UNLESS  THEY ARE  FAMILIAR  WITH  THESE 

OPERATION INSTRUCTIONS.

WARNING!  

NEVER DRAW 

OUTSIDE 

COMBUSTION AIR FROM A 

WALL, FLOOR OR CEILING CAVITY OR FROM ANY ENCLOSED 

SPACE SUCH AS AN ATTIC OR GARAGE.

These installation instructions describe the installation and opera-

tion of the 

QUADRA-FIRE ISLE ROYALE

 woodstove.  This stove 

meets the U.S. Environmental Protection Agency’s 1990 particulate 

emission standards.  The stove is listed by OMNI-Test Laborato-

ries, Inc. to UL Safety Standard 1482, and ULC S627, and (UM) 

84-HUD., Report number 061-S-18-2.   This stove is approved for 

mobile home installations when not installed in a sleeping room and 

when an outside combustion air inlet is provided.  The structural 

integrity of the mobile home floor, ceiling, and walls must be main-

tained.  The stove must be properly grounded to the frame of the 

mobile home and only use listed double-wall pipe.  Outside Air Kit, 

Part 831-1780 must be installed in a mobile home installation. 
Check with your local building code agency before you begin your 

installation to ensure compliance with local codes, including the 

need for permits and follow-up inspections.  Be sure local build-

ing codes do not supersede UL specifications and always obtain 

a building permit so that insurance protection benefits cannot be 

unexpectedly cancelled.  If any assistance is required during instal-

lation, please contact your local dealer.
Inspect and clean vent system frequently in accordance with the 

instructions contained in this manual.  Do not connect this unit to 

a chimney serving another appliance.
When using optional Blower, Part 831-1701, route power cord away 

from unit. Do not route cord under or in front of appliance.  
Do not elevate fire. Build wood fire directly on firebrick.  
Do not overfire - if heater or chimney connector glows, you are 

overfiring.  Stove thermometer recommended.
Operate only with the door closed unless using a firescreen.  Open 

only to add fuel to the fire.  Operating with the door open can cause 

hot embers or sparks to fall out and a fire may result.

INSTALLATION MATERIALS NEEDED FOR YOUR SAFETY

CHIMNEY CONNECTOR

 (also known as flue pipe or stove pipe):  

The chimney connector joins the stove to the chimney (

see page 

10)

.  It must be 6 inch (152mm) minimum diameter 24 MSG black 

or blued steel, or an approved air-insulated double wall venting 

pipe.

THIMBLE

:  A manufactured or site-constructed device installed in 

combustible walls through which the chimney connector passes 

to  the  chimney 

(see  page  11-12)

.    It  is  intended  to  keep  the 

walls from igniting.

CHIMNEY SYSTEMS

:

1.  APPROVED MASONRY 

(see specifications on page 13) 

with 

at least 5/8 inch (16mm) fire clay lining joined with refractory 

cement  or  other  listed  system  suitable  for  use  with  wood 

stoves.

2.  PREFABRICATED  6  inch  (152mm)  listed  high  temperature 

(UL 103 HT or ULC S629) chimney.  Components required 

by manufacturers for installation such as the chimney support 

base, firestop (as appropriate), attic insulation shield, insulated 

tee, etc., are necessary to assure a safe chimney installation.  

Use only components manufactured for the chimney.  Chimney 

installation should meet NFPA 211 standards.

FIRE SAFETY

:  To provide reasonable fire safety, the following 

should be given serious consideration:

1.  Install at least one smoke detector on each floor of your 

home to ensure your safety.  They should be located away 

from the heating appliance and close to the sleeping areas.  

Follow the smoke detector manufacturer’s placement and 

installation instructions, and be sure to maintain regularly.  

2.  A conveniently located Class A fire extinguisher to contend 

with small fires resulting from burning embers.

3.  A  practiced  evacuation  plan,  consisting  of  at  least  two 

escape routes.

4.  A plan to deal with a chimney fire as follows:
 

In the event of a chimney fire:
A.  Notify fire department.
B.  Prepare occupants for immediate evacuation.
C.  Close all openings into the stove.
D.  While awaiting fire department, watch for ignition of 

adjacent combustibles from overheated stove pipe, 

hot embers or sparks from the chimney.

VENTING SYSTEM

The  venting  system  consists  of  a  chimney  connector  and  a 

chimney.  These get extremely hot during use.  Temperatures 

inside the chimney may exceed 2000

°

F (1100

°

C) in the event of 

a creosote fire.  To protect against the possibility of a house fire, 

the chimney connector and chimney must be properly installed 

and maintained.  An approved thimble must be used when a 

connection is made through a combustible wall to a chimney.  

A chimney support package must be used when a connection 

is made through the ceiling to a prefabricated chimney.  These 

accessories are absolutely necessary to provide safe clearances 

to  combustible  wall  and  ceiling  material.    Follow  venting 

manufacturer’s clearances when installing venting system.

This stove may be connected to a lined masonry chimney or a 

listed high temperature prefabricated approved metal chimney.  

Do not connect it to a chimney serving another appliance.  To do 

so will affect the safe operation of both appliances.

Содержание Isle Royale

Страница 1: ...YOUR WARRANTY 4 Cool ashes should be disposed of carefully using a metal container 5 Do not burn wet or green wood Store wood in a dry location 6 DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLI...

Страница 2: ...DE L INSTALLATION LE CONTACT PEUT CAUSER DES BR LURES LA PEAU GARDEZ LES MEUBLES ET LES MAT RIAUX COMBUSTIBLES LOIN DE L ESPACE D SIGN DE L APPAREIL VOIR L TIQUETTE ET LES INSTRUCTIONS ESPACES LIBRES...

Страница 3: ...Plated Surfaces 22 Brick replacement 23 Door gasket 23 Exploded view 24 Accessories Service Part 25 Service Maintenance Log 26 Warranty 27 Contact Information 28 TABLE OF CONTENTS PRE USE CHECK LIST...

Страница 4: ...ove to the chimney see page 10 It must be 6 inch 152mm minimum diameter 24 MSG black or blued steel or an approved air insulated double wall venting pipe THIMBLE A manufactured or site constructed dev...

Страница 5: ...x inch 6 152mm diameter listed double wall air insulated connector pipe with listed factory built UL103 HT Class A chimney or a masonry chimney Mobile Home must be equipped with a spark arrestor and t...

Страница 6: ...FIREPLACE OR THROUGH THE WALL Six inch 6 152mm diameter listed double wall air insulated connector pipe with UL 103HT listed factory built Class A chimney or a masonry chimney Mobile Home must be equi...

Страница 7: ...DA 203mm 8 203mm 8 203mm 8 457mm 18 1251mm 49 1 4 Minimum 1137mm 44 3 4 Minimum 16 from glass std legs 8 USA Fuel loading door 36 3 4 Minimum 39 1 4 Minimum 18 from glass hearth legs WHEN LOCATING YOU...

Страница 8: ...f temperature difference from one side of the material to the other The LOWER the k factor means less heat is being conducted through the non combustible material to the combustible material beneath i...

Страница 9: ...t the other two and thus change the amount of draft in the entire system A source of air oxygen is necessary in order for combustion to take place The combustion air enters the rebox below the ash cat...

Страница 10: ...ire Protection Association NFPA Standard 211 It must have at least a 5 8 inch 16mm re clay liner or a listed chimney liner system See Figure 10B Make sure there are no cracks loose mortar or other sig...

Страница 11: ...nd combustible wall and 2 the 1 inch 25mm air space around the chimney connector as it passes through the chimney section to the chimney The location of the opening through the wall to the chimney mus...

Страница 12: ...inst the chimney Install the trim collar on the outside of the opening Check to ensure there is a 1 inch 25mm air space between the connector and the chimney section During installation ensure that a...

Страница 13: ...should t tightly and be sealed with high temperature furnace cement unless the kit s instructions state otherwise Figure 13 The tight tting installation aids the proper draw of the chimney Figure 13A...

Страница 14: ...purchase but they demonstrate the basic components necessary for a proper and safe installation The chimney must be the required height above the roof or other obstruction for safety and for proper d...

Страница 15: ...cted to a 6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS Floor protection referenced on page 7 must be followed 8 Use silicone to create an effective...

Страница 16: ...ion of the outside air kit rst NOTE If using Hearth Legs you can install an Outside Air Kit or Blower but not both 1 Remove 3 Phillips head screws from rear of unit 2 Using the Phillips head screws at...

Страница 17: ...d and not allowed to go out This will ensure the cleanest possible re If you are adjusting your stove for a low burn rate you should close down the air to the point where you can still maintain some a...

Страница 18: ...ate settings and will vary with type of wood or chimney draft Due to altitude and other environmental circumstances this operation infor mation is a guideline only Similar burn rates may be obtained u...

Страница 19: ...s 3 inches 76mm or 4 inches 102mm in diameter Be careful not to smother the re Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequa...

Страница 20: ...e blower off until your stove is hot and a good coalbed is established The blower may be turned on approximately 30 minutes after a good coalbed is established 2 High burn setting The blower may be le...

Страница 21: ...steps to ensure that the accumulation of ash and creosote falls directly into the rebox for removal MAINTENANCE ASH REMOVAL DISPOSAL The stove is equipped with an ash removal system We recommend empt...

Страница 22: ...ss This air ow washes the glass helping to keep smoke from adher ing to its surface When operated at a low burn rate less air will be owing over the glass and the smokey relatively cool condition of a...

Страница 23: ...is available from your dealer MAINTENANCE Ensure that the rebricks are correctly positioned as referenced by diagram below and that the rebox does not contain any broken brick prior to operating the u...

Страница 24: ...sembly 13 Griddle Handle 23 Rear Shield 4 Brick Assembly 14 Hopper Lid Stop 24 Side Tertiary Channel Right 5 Door Assembly 15 Manifold Tube 4 25 Side Left 6 Face Assembly 16 Primary Air Channel 26 Sid...

Страница 25: ...Tube Set 4 832 3360 Accessories Serial No Part No Blower 831 1701 Brackets with Mitten Rod Gold WSB2G 2 844 7980 Brackets with Mitten Rod Black WSB2 2 844 7970 Firescreen USA installations only 834 3...

Страница 26: ...R Page 26 February 4 2005 Isle Royale Wood Stove 250 5763B Date of Service Performed By Description of Service Service and Maintenance Log...

Страница 27: ...ears for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items...

Страница 28: ...0481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 D320652 D445174 D462436 Canada 1297749 2195264 2225408 or other...

Отзывы: