background image

4

09/20

7074-803C

F. Mobile Home Approved

•  This appliance is approved for mobile home 

installations when not installed in a sleeping room and 

when an outside combustion air inlet is provided.

• 

The structural integrity of the mobile home floor, ceiling, 

and walls must be maintained. 

•  The appliance must be properly grounded to the frame 

of the mobile home with #8 copper ground wire, and 

use only listed double-wall connector pipe.

• 

Outside Air Kit, part 811-0872 or OAK-3 must be 

installed in a mobile home installation.

•  Appliance must be secured to mobile home structure.

D. Glass Specifications

This appliance is equipped with 5mm ceramic glass. 

Replace glass only with 5mm ceramic glass. Please 

contact your dealer for replacement glass.

E. Electrical Rating (on high)

I. Sleeping Room

When installed in a sleeping room it is recommended that 

3ft of vertical be installed prior to horizontally exiting the 

room and a smoke/CO alarm be installed in the bedroom. 

The size of the room must be at least 50ft³ per 1,000 Btu/hr 

stove input, if the stove exceeds the room size, outside air 

must be installed.

J. Stove Composition

These pellet burning stoves are made of steel, cast iron or 

a combination of both with a ceramic viewing glass. These 

stoves incorporate a self-feeding system including a fuel 

storage hopper and a mechanical feed system which is 

controlled by a micro-processing control board. Each model 

contains a variable speed distribution blower to circulate 

room air through the heat exchanger and out to the room 

and a combustion blower which forces the exhaust out of 

the stove.

H. Combustible Materials

G. Non-Combustible Materials

Material which will not ignite and burn, composed of any 

combination of the following:

 - Steel

 - Plaster

 - Brick

 - Iron

 - Concrete

 - Tile

 - Glass

 - Slate

Materials reported as passing 

ASTM E 136, Standard 

Test Method for Behavior of Metals, in a Vertical Tube 

Furnace of 750° C

Material made of/or surfaced with any of the 

following materials:

 - Wood

 - Compressed Paper

 - Plant Fibers

 - Plastic

 -

Plywood/OSB

 - Sheet Rock (drywall)

Any material that can ignite and burn:

 flame proofed or not, 

plastered or non-plastered. 

K. California - Prop65

WARNING

This product and the fuels used to operate this product (wood), and 

the products of combustion of such fuels, can expose you to 

chemicals including carbon black, which is known to the State of 

California to cause cancer, and carbon monoxide, which is known to 

the State of California to cause birth defects or other reproductive 

harm. For more information go to: WWW.P65Warnings.ca.gov

NOTE:

 Hearth & Home Technologies, manufacturer 

of this appliance, reserves the right to alter 

its products, their specifications and/or price 

without notice.

Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage.

For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

•  Installation and use of any damaged appliance.

• 

Modification of the appliance.

•  Installation other than as instructed by Hearth & 

Home Technologies.

•  Installation and/or use of any component part not 

approved by Hearth & Home Technologies.

• 

Operating appliance without fully assembling 

all components.

• 

Operating appliance without legs attached (if 

supplied with appliance).

• 

Do NOT Over fire

 - If appliance or chimney connector 

glows, you are over firing.

Any such action that may cause a fire hazard.

WARNING

Fire Risk

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be 

voided by, the following actions:

115 VAC, 60 Hz, Start 5.1 Amps, Run 3.0 Amps

Содержание CAB50-C

Страница 1: ...comply may cause house fire HOT SURFACES Glass and other surfaces are hot during operation AND cool down WARNING Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children...

Страница 2: ...arted A Design Installation Location Considerations 5 B Thermostat Wall Control Location 6 C Tools And Supplies Needed 6 D Inspect Appliance and Components 6 E Install Checklist 7 3 Dimensions and Cle...

Страница 3: ...hour LHV Tested Efficiency 69 5 HHV Tested Efficiency 65 1 EPA BTU Output 7 500 to 36 600 per hr BTU Input 13 100 to 49 900 per hr Vent Size 3 or 4 Type L or PL Hopper Capacity 120 lbs Fuel Premium W...

Страница 4: ...composed of any combination of the following Steel Plaster Brick Iron Concrete Tile Glass Slate Materials reported as passing ASTM E 136 Standard Test Method for Behavior of Metals in a Vertical Tube...

Страница 5: ...ght requirement prior to installation The weight of the appliance is 240 lbs NOTICE Check building codes prior to installation Installation MUST comply with local regional state and national codes and...

Страница 6: ...the installation to ensure maximum safety and benefit Follow pipe manufacturer instructions for installation and air clearance requirements Risk of Fire Damaged parts could impair safe operation Do N...

Страница 7: ...ng this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the appliance Check...

Страница 8: ...e Dimensions Figure 8 3 Front View Figure 8 1 Top View Figure 8 2 Side View 10 in 252mm 10 in 252mm 2 1 4 in 59mm 23 3 4 in 603mm 36 1 2 in 927mm 9 1 2 in 243mm 24 1 2 in 622mm 12 1 2 in 318mm 25 7 8...

Страница 9: ...nch Offset Adapter 811 0720 Figure 9 4 Side View w Top Vent Adapter TPVNT 5 3 to 4 inch Offset Adapter 811 0720 Figure 9 1 Top View w Top Vent Adapter TPVNT 5 12 1 4 in 311mm 12 1 4 in 311mm 2 7 8 in...

Страница 10: ...5 3 to 6 inch Offset Adapter 812 3570 12 1 4 in 311mm 12 1 4 in 311mm 4 1 8 in 103mm 4 1 8 in 103mm 28 1 8 in 714mm 28 1 8 in 714mm 30 1 8 in 765mm 30 1 8 in 765mm Figure 10 3 Top View w Top Vent Adap...

Страница 11: ...ter TPVNT 6 3 to 4 inch Offset Adapter 811 0720 Figure 11 2 Side View w Top Vent Adapter TPVNT 6 3 to 4 inch Offset Adapter 811 0720 9 7 8 in 252mm 9 7 8 in 252mm 3 1 8 in 80mm 3 1 8 in 80mm 15 1 8 in...

Страница 12: ...Back Wall to Adapter 1 25 E Side Wall to Appliance 14 356 F Back Wall to Appliance 6 1 4 159 Corner Installation Inches Millimeters G Walls to Appliance 2 51 Vertical Installation Inches Millimeters...

Страница 13: ...ach side of pipe shaded area to the wall thimble 152mm Front of glass 348mm USA INSTALLATIONS A non combustible floor protection is recommended extending beneath the flue pipe when installed with hori...

Страница 14: ...3 4 1441 n a n a B Width 53 1346 n a n a C Depth n a n a 48 1219 D To Side Wall 14 356 n a n a All minimums listed are to a combustible surface NOTE Illustrations reflect typical installations and ar...

Страница 15: ...rts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table below 24 in Abo...

Страница 16: ...d may consume the air needed for the appliance It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HVAC professional to dete...

Страница 17: ...mney Install through the warm airspace enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Considerations for successful draft includ...

Страница 18: ...re 18 2 1 Locate the calculated equivalent feet of pipe on the vertical left side of the chart 2 Move to the right horizontally on the chart until you reach your altitude above sea level 3 If you fall...

Страница 19: ...best for your installation 2 in 51mm Minimum 2 in 51mm Minimum 6 in 152mm Minimum 6 in 152mm Minimum Figure 19 2 5 Venting Systems NOTE In Canada where passage through a wall or partition of combusti...

Страница 20: ...tructions for all reduced air clearances installations B Vertical into Existing Class A Chimney Firestop Flashing Rain Cap 6 in 152mm Minimum Non combustible Hearth Pad 3 in 76mm Minimum Cleanout Cove...

Страница 21: ...Flue Liner with Airspace Concrete Cap Non combustible Hearth Pad Airtight Clean Out Door Clean Out cover Sheathing 3 in 76mm Minimum 1 in 25mm Clearance Flashing Fireclay flue Liner with Airspace Con...

Страница 22: ...ation Cap Hose Clamp Trim Ring 2 inch flex hose Hose Clamp Collar Assembly Air Intake Channel Discard Figure 22 2 1 Measure distance from floor to air vent opening in appliance and mark location on wa...

Страница 23: ...ady in the short horizontal pipe in the top vent adapter as a guide Install the 2 screws Figure 23 1 6 Install the vent pipe into the top vent adapter 7 To clean the top vent adapter open the clean ou...

Страница 24: ...the thermostat from the mounting plate by gently pulling the two pieces apart c Slide thermostat wires through the back of the mounting plate Figure 24 3 d Connect your thermostat wire to the terminal...

Страница 25: ...Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 25 1 CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED Do NOT cu...

Страница 26: ...26 09 20 7074 803C A Service Maintenance Log 8 Reference Materials Date of Service Performed By Description of Service...

Страница 27: ...27 09 20 7074 803C Date of Service Performed By Description of Service...

Страница 28: ...28 09 20 7074 803C Date of Service Performed By Description of Service...

Страница 29: ...29 09 20 7074 803C Date of Service Performed By Description of Service...

Страница 30: ...0 0810 Power Cord 812 1180 Y Thermostat Mechanical 812 3760 Y Touch Up Paint 3 42 19905 Fuse 7 Amp Junction Box Pkg of 10 812 0380 10 Y Hose Vacuum 5 32 Id 3 Ft SRV240 0450 Y Hose Barb Assembly SRV229...

Страница 31: ...ner Packs Rivnut Repair Kit RIVNUT REPAIR Y Bolt Hex Head 1 4 20 X 1 Pkg of 10 25221A 10 Y Guide Pin Sleeve Pkg of 25 31120 25 Y Hurricane Screw Pkg of 40 SRV2005 861 40 Nut 2 Wy Side Lock Jam 3 Pkg o...

Страница 32: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: