background image

 15

7033-362C

11/21

Negative pressure results from the imbalance of air 

available for the appliance to operate properly. It can be 

strongest in lower levels of the house.

Causes include:

• 

Exhaust fans (kitchen, bath, etc.)

•  Range hoods

• 

Combustion air requirements for furnaces, water 

appliances and other combustion appliances

•  Clothes dryers

•  Location of return-air vents to furnace or air 

conditioning

• 

Imbalances of the HVAC air handling system

•  Upper level air leaks such as: 

 - Recessed lighting

 - Attic hatch

 - Duct leaks

K. Negative Pressure

ISSUES

SOLUTIONS

Odor from appliance

When first operated, this appliance may release an odor for the first several hours. This is 

caused by the curing of the paint and the burning off of any oils remaining from manufacturing.

Metallic noise

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to 

the sound produced by a furnace or heating duct. This noise does not affect the operation or 

longevity of the appliance.

Whirring sound

If the optional blower has been installed, the blower produces a whirring sound which 

increases in volume as the speed is increased.

L. Frequently Asked Questions

To minimize the effects of negative air pressure:

•  Install the outside air kit with the intake facing prevailing 

winds during the heating season

• 

Ensure adequate outdoor air for all combustion 

appliances and exhaust equipment

•  Ensure furnace and air conditioning return vents are 

not located in the immediate vicinity of the appliance

•  Avoid installing the appliance near doors, walkways or 

small isolated spaces

• 

Recessed lighting should be a “sealed can” design

•  Attic hatches weather stripped or sealed

•  Attic mounted duct work and air handler joints and 

seams taped or sealed

WARNING

Asphyxiation Risk.

•  Negative pressure can cause spillage 

of combustion fumes, soot and 

carbon monoxide.

•  Appliance needs to draft properly 

for safety.

WARNING

Fire Risk.

•  DO NOT BURN GARBAGE OR 

FLAMMABLE FLUIDS SUCH AS 

GASOLINE, NAPHTHA OR ENGINE OIL.

• 

Do NOT burn treated wood or wood with 

salt (driftwood).

• 

May generate carbon monoxide if burn 

material other than wood.

May result in illness or possible death.

Fire Risk.

Keep combustible materials, gasoline and 

other flammable vapors and liquids clear of 

appliance.

WARNING

• 

Do NOT store flammable materials in the 

appliance’s vicinity.

•  DO NOT USE GASOLINE, LANTERN FUEL, 

KEROSENE, CHARCOAL LIGHTER FLUID OR 

SIMILAR LIQUIDS TO START OR “FRESHEN UP” A 

FIRE IN THIS APPLIANCE.

•  Keep all such liquids well away from the appliance 

while it is in use.

• 

Combustible materials may ignite.

CONTACT YOUR DEALER for additional information regarding operation and troubleshooting.

Visit 

www.quadrafire.com

 to find a dealer

Table 15.1

Содержание 31M-ACC-AU

Страница 1: ...high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away WARNING Fire Risk For use with solid wood fuel...

Страница 2: ...ES ACC FREESTANDING WOOD STOVE OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD WHEN TESTED IN ACCORDANCE WITH AS NZS 4012 71 AVERAGE PARTICULATE EMISSION FACTOR BURNING HARDWOOD WHEN TESTED IN ACCORDANCE...

Страница 3: ...ations 7 C Glass Specifications 7 2 Operating Instructions A Over Firing Your Appliance 8 B Wood Selection Storage 8 C Burning Process 8 D Air Controls 9 E Using Burn Rate Air Control ACC System 9 F B...

Страница 4: ...Limitations listed 2 years X X Igniters Auger Motors Electronic Components and Glass X Electrical components limited to modules remotes wall switches valves pilots fans junction boxes wire harnesses...

Страница 5: ...fied in the operating instructions 7 installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the applia...

Страница 6: ...components due to water or weather damage which is the result of but not limited to improper chimney or venting installation HOW TO CLAIM To make a claim against this warranty contact your local dist...

Страница 7: ...D KINDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The applian...

Страница 8: ...dry basis Standard AS NZS 2918 2001 1 Listing and Code Approvals NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or pric...

Страница 9: ...rm the way they are designed to perform Improper operation can turn most any wood appliance into a smoldering environmental hazard 3 Kindling or First Stage It helps to know a little about the actual...

Страница 10: ...of heat needed to dry and rekindle the next load of wood It is best to open the Burn Rate Air and Start Up Air Controls before reloading This livens up the coal bed and reduces excessive emissions op...

Страница 11: ...te Air Control spring handle up to high position for 5 minutes Then activate the ACC timer system by pushing the knob all the back toward the appliance to HI then pull forwards towards the front of th...

Страница 12: ...Air and ACC Controls fully refer Start Up Guide on page 7 4 Place several wads of crushed paper on the firebox floor Heating the flue with slightly crumpled newspaper before adding kindling keeps smok...

Страница 13: ...with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket CAUTION The baffle boards are FRAGILE Use extreme caution when...

Страница 14: ...e clothing furniture or draperies WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Do NOT burn treated wood or wood with salt driftwood May generate car...

Страница 15: ...ntake facing prevailing winds during the heating season Ensure adequate outdoor air for all combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located...

Страница 16: ...measured from bottom of appliance This will prevent pipe blockage poor draft and chimney res Always burn dry wood to help prevent cap blockage and creosote build up Firebrick Ash Removal WEEKLY or aft...

Страница 17: ...nector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it should be removed to...

Страница 18: ...leaner left on during the next firing can permanently stain the glass and damage the finish on metal surfaces A portion of the combustion air entering the firebox is deflected down over the inside of...

Страница 19: ...height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not establ...

Страница 20: ...er tighten the handle needs to rotate smoothly 6 Install fiber handle Figure 20 1 Locknut Latch Cam Spacing Washers Door Cross Section example Door Handle Fiber Handle Square Key B Firebrick Replaceme...

Страница 21: ...e install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 21 3 5 To re install the ceramic blanket it is easier...

Страница 22: ...annel assembly a clearance of 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available the appliance will have to be disconne...

Страница 23: ...23 7033 362C 11 21 6 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 24: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...