 22

7033-362C

11/21

Figure 22.1

Channel 

Access 

Cover 

Channel 

Nuts (2) 

Side Panel

Tube Channel 

Assembly 

Channel Cover 

Screws (4) 

Tube Channel Rack 

Remove 

2 Screws 

Slide one gasket 

over each tube

E. Tube Channel Assembly

Removing Tube Channel Assembly

1. 

Remove the right side shield by lifting up on side 

to remove.

2.  Remove 4 screws from channel access cover and 

remove cover.

3. 

Locate 2 channel nuts inside of chamber and 

remove using a 7/16 socket wrench. Slide out tube 

channel assembly.

NOTE: Service Space

In order to replace the tube channel assembly a 

clearance of 483mm is required on the right side of 

appliance in order to remove the tubes with the appliance 

in place.

If space is not available, the appliance will have to be 

disconnected from the chimney to proceed with the tube 

replacement.

NOTE:

 Soak the bolts with penetrating oil for at least 15 

minutes before trying to remove them.

Replacing Tube Channel Assembly

4. 

Slide one gasket onto each tube.

5. 

Slide the tube channel assembly into side of firebox 

and insert each tube into the corresponding hole in the 

tube channel rack starting with the back hole first.

6. 

Make sure tube channel assembly is flush against the 

side of the appliance and secure with channel nuts.

7.  Re-install channel cover and side shield.

Содержание 31M-ACC-AU

Страница 1: ...high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away WARNING Fire Risk For use with solid wood fuel...

Страница 2: ...ES ACC FREESTANDING WOOD STOVE OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD WHEN TESTED IN ACCORDANCE WITH AS NZS 4012 71 AVERAGE PARTICULATE EMISSION FACTOR BURNING HARDWOOD WHEN TESTED IN ACCORDANCE...

Страница 3: ...ations 7 C Glass Specifications 7 2 Operating Instructions A Over Firing Your Appliance 8 B Wood Selection Storage 8 C Burning Process 8 D Air Controls 9 E Using Burn Rate Air Control ACC System 9 F B...

Страница 4: ...Limitations listed 2 years X X Igniters Auger Motors Electronic Components and Glass X Electrical components limited to modules remotes wall switches valves pilots fans junction boxes wire harnesses...

Страница 5: ...fied in the operating instructions 7 installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the applia...

Страница 6: ...components due to water or weather damage which is the result of but not limited to improper chimney or venting installation HOW TO CLAIM To make a claim against this warranty contact your local dist...

Страница 7: ...D KINDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The applian...

Страница 8: ...dry basis Standard AS NZS 2918 2001 1 Listing and Code Approvals NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or pric...

Страница 9: ...rm the way they are designed to perform Improper operation can turn most any wood appliance into a smoldering environmental hazard 3 Kindling or First Stage It helps to know a little about the actual...

Страница 10: ...of heat needed to dry and rekindle the next load of wood It is best to open the Burn Rate Air and Start Up Air Controls before reloading This livens up the coal bed and reduces excessive emissions op...

Страница 11: ...te Air Control spring handle up to high position for 5 minutes Then activate the ACC timer system by pushing the knob all the back toward the appliance to HI then pull forwards towards the front of th...

Страница 12: ...Air and ACC Controls fully refer Start Up Guide on page 7 4 Place several wads of crushed paper on the firebox floor Heating the flue with slightly crumpled newspaper before adding kindling keeps smok...

Страница 13: ...with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket CAUTION The baffle boards are FRAGILE Use extreme caution when...

Страница 14: ...e clothing furniture or draperies WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Do NOT burn treated wood or wood with salt driftwood May generate car...

Страница 15: ...ntake facing prevailing winds during the heating season Ensure adequate outdoor air for all combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located...

Страница 16: ...measured from bottom of appliance This will prevent pipe blockage poor draft and chimney res Always burn dry wood to help prevent cap blockage and creosote build up Firebrick Ash Removal WEEKLY or aft...

Страница 17: ...nector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it should be removed to...

Страница 18: ...leaner left on during the next firing can permanently stain the glass and damage the finish on metal surfaces A portion of the combustion air entering the firebox is deflected down over the inside of...

Страница 19: ...height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not establ...

Страница 20: ...er tighten the handle needs to rotate smoothly 6 Install fiber handle Figure 20 1 Locknut Latch Cam Spacing Washers Door Cross Section example Door Handle Fiber Handle Square Key B Firebrick Replaceme...

Страница 21: ...e install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 21 3 5 To re install the ceramic blanket it is easier...

Страница 22: ...annel assembly a clearance of 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available the appliance will have to be disconne...

Страница 23: ...23 7033 362C 11 21 6 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 24: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: