2100-I & 3100-I FIREPLACE INSERT
Page 18
March 1999
The Quadra-Fire 2100-I and 3100-I models conform with the safety standard UL-
1482 in all respects and is approved to UL safety standards for installation and use within a
fireplace with masonry chamber, in accordance with NFPA No. 211, with or without a
direct flue collar connection. A starter pipe is required into existing chimney.
METAL HEAT EXCHANGER MASONRY
SAMPLE INSTALLATION INTO METAL HEAT EXCHANGER
SHO
SHO
SHO
SHO
SHOWING USE OF ST
WING USE OF ST
WING USE OF ST
WING USE OF ST
WING USE OF STAR
AR
AR
AR
ARTER P
TER P
TER P
TER P
TER PIP
IP
IP
IP
IPE
E
E
E
E
FACTORY BUILT FIREPLACE
(ZERO CLEARANCE)
The Quadra-Fire 2100-I and 3100-I are also listed to UL Standards for Safety 127, and
approved for installation and use in factory built zero clearance fireplaces conforming to the
following specifications:
2100-I
3100-I
Minimum Width of cavity opening: 29 (737mm)
32 (813mm)
Minimum Height:
21 (533mm)
23 (584mm)
Depth of the firebox may vary according to brand name, however the top rear corners of
the insert require a 2 (51mm) space between the insert and the side and back walls of the fire-
place unit. Installation into larger sizes of factory built fireplaces of the above-named brands is
permissible.
The following modifications of factory built fireplaces are permissible. 1) Removal of
damper. 2) Removal of smoke shelf or baffle. 3) Removal of ember catches. 4) Removal of fire
grate. 5) Removal of viewing screen/curtain. 6) Removal of doors.
HEA
T
EXCHANGER
INST
ALLA
TION
:
MANTEL
LISTED LINER
SEAL DAMPER AREA OR FACE SEAL