background image

Hardware installation manual 

Qtech Platform 2U Server Product Technical Manual 

 
 

www.qtech.ru 

 

 

2.1.

 

System Introduction  

The  Qtech  1U  server is a new generation of 1U  dual cabinet server with a wide range of 

applications that QTECH  has developed for Internet, IDC (Internet Data Center), cloud 

computing, enterprise market and telecom service applications.  Suitable for IT core business, 

cloud computing virtualization, high performance computing, distributed storage, big data 

processing, enterprise or telecom service applications and other complex workloads.

 

The server 

has the advantages of low energy consumption, strong scalability, high reliability, easy 

management, and easy deployment.

 

2.2.

 

System Configuration  

Qtech 1U products include 1U4 (3.5" hard disk), 1U10 (2.5" hard disk) disk type 3 kinds of models 

in addition to the hard disk connection, compatible with the largest number of different hard 

drives, other specifications are the same. 

 

System parameters 

Features

 

Technical specifications

 

model 

1U 

size 

1U cabinet type, standard with guide rails, maximum depth: 640 mm 

processor 

Supports 1 or 2 Intel 

Haswell-EP E5-2600 V3 series processor(135W 

maximumly), Brodwell EP  processoris compatible

 

Содержание 1U

Страница 1: ...HARDWARE INSTALLATION MANUAL www qtech ru QSRV RMC Platform Hardwareinstallationmanual 1 0...

Страница 2: ...unt when using this product the precautions and the description of the laws and regulations related to the product Chapter 2 Product Introduction This section provides the specifications of the major...

Страница 3: ...on 13 Chassis Structure 14 Front panel lights and buttons instructions 15 Rear Window Contruction 16 Motherboard components 17 Hard disk backplane assembly 23 Install rear backplane 2 2 5 26 Hard disk...

Страница 4: ...Set RAID options in BIOS 85 4 6 1 Intel Rapid Storage Technology Enterprise SATA Option ROM Utility setup program 87 6 2 LSI SAS3008 Group RAID 93 Configuring RAID in UEFI Boot Mode 93 Legacy boot mod...

Страница 5: ...s can be used but they must be physically connected to the ground If you are not sure if you have a safe grounding protection contact the appropriate agency or electrician for confirmation If you need...

Страница 6: ...void frequent restart or switch on and off to extend the life of your computer Please keep the environment clean and avoid dust The working temperature of the equipment is 10 C 35 C and the humidity i...

Страница 7: ...nts PCA X O O O O O Cable wire con nector X O O O O O Hard disk drive X O O O O O Part Name Harmful Substance lead HG cadmiu m Hexavalen t chromium Polybrominate d biphenyls PBDE Pb Hg Cd Cr VI PBB PB...

Страница 8: ...HS directive including its exemption clause Note This table shows the status of toxic and hazardous substances contained in all possible parts of QTECH server memory and workstation products Customers...

Страница 9: ...gy Co Ltd is not responsible for the hardware and data damage caused by this When a server fails first check the Troubleshooting section of this manual to identify and troubleshoot common problems If...

Страница 10: ...or telecom service applications and other complex workloads The server has the advantages of low energy consumption strong scalability high reliability easy management and easy deployment 2 2 System C...

Страница 11: ...5 inch SAS SATA HDD SSD Front Bay Up to 10 hot swappable 2 5 inch SAS SATA HDD SSD Rear Bay Up to 2 hot swappable 2 5 inch SAS SATA HDD SSD power supply Platinum class 550W 770Whot swappable redundan...

Страница 12: ...ht and power button with alarm function 4pcs USB3 0 interface 4pcs USB2 0 interface and 1pcs vertical internal USB3 0 Connector 1pcs VGA port and 1pcs RS 232 port 2pcs 10000Mbps network controller emb...

Страница 13: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 9 www qtech ru 2 3 System model specifications 1U4 tray 3 5 inch disk model...

Страница 14: ...r 135W maximumly Brodwell EP processoris compatible chipset Intel C612 Series Server Specific Chipset RAM Each DIMM support 32GB RDIMM 64GB LRDIMM maximumly Maximum 1024GB for whole motherboard DDR4 2...

Страница 15: ...00Mbps business net port 2pcs 10000Mbps business net port PCIE expansion board up to 6 PCIE third generation slots HLHH System fan 5 N 1 hot swap redundant fan On motherboard 8x 1X4 pin FAN Connector...

Страница 16: ...ies processor 135W maximumly Brodwell EP processoris compatible chipset Intel C612 Series Server Specific Chipset RAM Each DIMM support 32GB RDIMM 64GB LRDIMM maximumly Maximum 1024GB for whole mother...

Страница 17: ...t port 2pcs 10000Mbps business net port PCIE expansion board up to 6 PCIE third generation slots HLHH System fan 5 N 1 hot swap redundant fan On motherboard 8x 1X4 pin FAN Connector The internet Two o...

Страница 18: ...ual Qtech Platform 2U Server Product Technical Manual 14 www qtech ru Chassis Structure No Description 1 Base 2 Rear Windows 3 Ventilation wall 4 Hard disk module 5 Front cover 6 Top cover 7 Handle 8...

Страница 19: ...ical Manual 15 www qtech ru Front panel lights and buttons instructions LED Status Description No Picture LED Appearance Description LOGO label labeling or customized acrylic label The green light is...

Страница 20: ...rm power alarm etc the specific can be viewed through IPMI management software The green light is on Internet access 1 connection is normal The green light is on Internet access 2 connection is normal...

Страница 21: ...tform 2U Server Product Technical Manual 17 www qtech ru Motherboard components All the models share the mainboard components The interface description is as follows Connector name Function descriptio...

Страница 22: ...B3 0 overlay connector D31 The mainboard identity indicator the user can control the indicator light to turn on or off through IPMI When it is lit it is blue or it can be controlled through the front...

Страница 23: ...TPM module or 80Port Debug card JUSB1 Dual USB2 0 Connector you can use the adapter cable to transfer two USB2 0 to the front panel JUSB2 Dual USB2 0 Connector you can use the adapter cable to transf...

Страница 24: ...0 6Gb s SATA7 SATA Connector7 SATA3 0 6Gb s SATA8 SATA Connector8 SATA3 0 6Gb s SATA9 SATA Connector9 SATA3 0 6Gb s SATA10 SATA Connector10 SATA3 0 6Gb s SYS_FAN1 System FAN1 SYS_FAN2 System FAN2 SYS...

Страница 25: ...o connect the power supply the pin definition complies with SSI specification J12 ATX PWR 8Pin Connector used to connect the power supply the pin definition complies with SSI specification JPMBUS1 Pow...

Страница 26: ...CIE X8 Connector is from CPU1 JSGPIO1 5pin PCH SATA SGPIO Connector on board JSGPIO2 5pin PCH SATA SGPIO Connector on board JP1 Chassis Intrusion Chassis intrusion pin on the board optional function w...

Страница 27: ...update is complete In other cases the jumper is not required JBAT1 CMOS CLEAR Clear the CMOS Connector the jumper is not connected by default and the jumper is valid when plugged in JP3 ME RECOVERY Pl...

Страница 28: ...ATA hard disk connector 1 Maximum support 12G b SAS hard drive 2 Maximum support 6G b SATA hard disk 3 Support SAS SATA hard disk hot swap BOTTOM face Numbering Device description Functional descripti...

Страница 29: ...7 12 Sockets of 4 temperature control fans 13 MINI SAS HD SFF 8643 12Gb High Speed Connector Used for transmission of 12G b SAS or 6G b SATA signals 1U12 3 5 expansion backplane as shown Top face ITEM...

Страница 30: ...of 12V power 4 5 6 7 4 Sockets of 4PIN temperature control fans Control FAN RPM and backplane temperature 8 9 10 MINI SAS HD SFF 8643 12Gb High Speed Connector Used for transmission of 12G b SAS or 6G...

Страница 31: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 27 www qtech ru Install two 2 5 inch hard disks on HDD tray Insert two 2 5 inch hard disks into the rear hard disk module...

Страница 32: ...l 28 www qtech ru The installation effect is as follows Note for if the customer selects two 2 5 inch hot swap hard disks they must be equipped with CRPS power supply Hard disk label 1U4 tray 3 5 inch...

Страница 33: ...ta activity ON OFF Hard disk in place and normal activities The flash frequency of the hard disk itself OFF Hard disk failure N A ON Hard disk is positioned N A 4HZ blinks Hard disk is in Rebuild stat...

Страница 34: ...our CPU uses a Gooxi certified radiator Detailed steps to install LGA2011 processor 1 Press down the left fixed wrench A and push it slightly to the right B until the wrench is free from the fixing bu...

Страница 35: ...tform 2U Server Product Technical Manual 31 www qtech ru 3 Push the left fixed wrench in the direction of the arrow and lift the upper cover of the installation box G hold the edge and gently lift the...

Страница 36: ...cket and put the CPU into the socket carefully caveat The CPU can only be correctly installed in the motherboard socket in one direction Do not use force to install the CPU in the socket in the wrong...

Страница 37: ...the upper cover of the installation box is fixed by the wrench J and then insert the right fixing wrench into the fixing buckle caveat Please keep the protective cover only the motherboard with the p...

Страница 38: ...ator and apply appropriate amount of thermal silicone paste on the bottom of the radiator 2 Place the heat sink on the top of the CPU so that the four mounting holes are aligned with the motherboard a...

Страница 39: ...r slots Should pay attention to the memory of the gap with the DIMM slot gap each DIMM module vertically snap into place to prevent the incorrect installation The memory slot shall be aligned with tha...

Страница 40: ...rules For single CPU settings please refer to the following recommended memory settings For dual CPU settings please refer to the following recommended memory settings The 8 memory slots controlled b...

Страница 41: ...ng or removing DIMM memory modules to prevent any possible damage to the DIMMs or their respective sockets Installation insert the memory module vertically and press the location of the memory slot sn...

Страница 42: ...38 www qtech ru 3 3 Hard disk installation 1 Installing a 3 5 inch hard disk 1 1 Put the hard disk in the tray 1 2 There are 4 countersunk screws on the left and right sides to lock the hard disk the...

Страница 43: ...Platform 2U Server Product Technical Manual 39 www qtech ru Installing a 2 5 inch hard disk 1 1 Put the hard disk in the tray 1 2 The bottom four countersunk screws lock the hard disk screw head protr...

Страница 44: ...rdware installation manual Qtech Platform 2U Server Product Technical Manual 40 www qtech ru Hard disk tray assembly installed in the chassis 1 1 With the hard disk wrench open push it into the chassi...

Страница 45: ...n manual Qtech Platform 2U Server Product Technical Manual 41 www qtech ru 1 2 When the hard disk gold finger touches the backplane device turn the wrench in the direction of the arrow 1 3 Hard Disk I...

Страница 46: ...ech Platform 2U Server Product Technical Manual 42 www qtech ru 3 4 Fan module installation Install 8 soft nails to the fan as shown in the figure below Steps Insert the hot swap fan into the fan sock...

Страница 47: ...ware installation manual Qtech Platform 2U Server Product Technical Manual 43 www qtech ru Complete the installation as shown in the following figure Installation of 4 fans completed final effect draw...

Страница 48: ...atform 2U Server Product Technical Manual 44 www qtech ru 3 5 Installation Steps of Two 2 5 inch Non Hot Swappable Hard Disks Remove the screws marked at the following figure lift the top cover and re...

Страница 49: ...ware installation manual Qtech Platform 2U Server Product Technical Manual 45 www qtech ru Fix the two 2 5 inch hard disks with expandable bracket respectively The final installation effect is as foll...

Страница 50: ...al Qtech Platform 2U Server Product Technical Manual 46 www qtech ru Install the expandable hard disk to the chassis as shown in the figure below The final installation effect of expandable hard disk...

Страница 51: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 47 www qtech ru...

Страница 52: ...foolproof design Pin4 foolproof design This connector is reserved mainly to connect to the front panel LED Power Button etc The position of the power on button is at Pin 23 and Pin 24 of the Front Pan...

Страница 53: ...r in the motherboard lights up when PWROK 7 HDD_LED 8 HDD_LED Hard disk working status indicator yes Flashes when reading data other states are always off 9 NIC_LED 10 NIC_LED Business network port 1...

Страница 54: ...k port 4 activity indicator synchronized with the network port 4 active light flashes when there is data access 17 UID ID 18 FAN_FAIL_LED Fan error indicator lights up when the fan has an error 19 P3V...

Страница 55: ...emoval of the inner rail 1 4 Push a snap in the guide rail in the direction of the arrow 1 5 Simultaneously pushing the middle rail into sliding rail 1 6 Complete Step 1 2 Step 2 Install the inner rai...

Страница 56: ...nstallation 3 1 Push the rear end hook of the guide rail in accordance with the arrow align the cabinet hole position and install the guide rail into the cabinet 3 2 After installing the rail into the...

Страница 57: ...n both sides of the cabinet and hear a click and stop 4 2 Raise the server and align the guide rails with the center rails Push the server into the cabinet in the direction of the arrow to ensure that...

Страница 58: ...t Technical Manual 54 www qtech ru 4 5 Open the front mounting ears on both sides and use a screwdriver to tighten the screws Complete step 4 Note To remove the server from the cabinet unlock the scre...

Страница 59: ...or ESC to enter setup F7 to enter Boot Menu 3 Press the DEL or ESC key to enter the BIOS Setup interface 5 2 Setup menu parameter description Navigation key description Menu Switch Select Screen Item...

Страница 60: ...erver Board Information Project Version Displays the BIOS version of the board Build Date and Time Displays the compilation date and time of the board BIOS Manufacturer Display the board manufacturer...

Страница 61: ...uage System Date Displays and sets the current system date The format of the system date is weekly month day year Press Enter to switch between months days and years You can change the value by Press...

Страница 62: ...tion Main interface Please be careful when changing the menu option settings of Advanced Incorrect values may cause system failure HW Monitor Configuration This project mainly monitors the temperature...

Страница 63: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 59 www qtech ru 1 ACPI settings...

Страница 64: ...tions Enabled Disabled you can enable or disable ACPI Enable Hibernation turn off Enabled OS S4 is in sleep state The setting values are Enabled and Disabled AST2400 IO settings Serial PortEnabled D S...

Страница 65: ...erial PortEnabled D Serial Port 2 Configuration isabled Two options you can enable and disable serial port debugging Change Setting can be selected as manual or automatic mode Serial control managemen...

Страница 66: ...to Unicode characters ANSI Extended ASCII character setting Bits per second 115200 Select the serial port transmission speed the transmission speed must be consistent with the other end long line or...

Страница 67: ...verflow control to reduce the possibility of data loss The setting values are None Hardware RTS CTS Recorder Mode Disabled Only text can be sent when this option is enabled This option is used to capt...

Страница 68: ...will detect whether there is a USB device when it is turned on if so the USB controller backward compatibility mode is turned on if no USB device is detected the USB backward compatibility function w...

Страница 69: ...ontrol switch the menu options are Enabled On Disabled Off Default Enabled 1 5 2 3IntelRCSetup 1 Processor settingsThis item allows you to know more clearly the information of the central processing u...

Страница 70: ...le Bit When disabled the XD function flag is forced to return to 0 all the time Hardware Prefetcher Enable or disable the hardware pre read function Adjacent Cache Prefetch Open and close the adjacent...

Страница 71: ...rver Product Technical Manual 67 www qtech ru CPU C State Control Set a series of options to enhance CPU performance CPU T State Control Set whether the CPU can be throttled by the system Throttling w...

Страница 72: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 68 www qtech ru 4 List of memory topologies Show memory list...

Страница 73: ...5 PCH configuration PCH sSATA Configuration sSATA configuration SATA Controller Turn on or turn off the sSATA controller SATA Mode options SATA Led Locate function on and off SATA Port 0 3 setting op...

Страница 74: ...ww qtech ru PCH SATA Configuration SATA configuration SATA Controller Turn on or turn off the sSATA controller SATA Mode options SATA Led Locate function on and off SATA Port 0 5 setting options Inclu...

Страница 75: ...ch Platform 2U Server Product Technical Manual 71 www qtech ru USB Controller Configuration USB controller configuration xHCI Mode The operating mode of the xHCI controller can be selected as Smart Au...

Страница 76: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 72 www qtech ru 6 General ME Configuration ME configuration information...

Страница 77: ...Slot 1 The opening and closing of the port the connection speed setting CPU0 PCIE X16 Slot2 The opening and closing of the port the connection speed setting CPU0 PCIE X8 Slot 1 The opening and closin...

Страница 78: ...Platform 2U Server Product Technical Manual 74 www qtech ru Restore AC Power Loss Last State Set the state after the power is reloaded as on off last state Displays information such as the version st...

Страница 79: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 75 www qtech ru 2 5 2 Server Remote Management Menu Server MGMT BMC self test log BMC self check record...

Страница 80: ...roduct Technical Manual 76 www qtech ru Erase Log No Delete log options respectively Yes On every reset No When log is full Clear Log The operation after the log file is full is Clear Log Do not log a...

Страница 81: ...nspecified Configuration URL method respectively Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp BMC Warm Reset BMC restart 3 5 2 Security menu Security This menu allows you to create a new passwo...

Страница 82: ...art of the BIOS Please follow the steps below to set the system administrator password Select the Administrator Password item and press the Enter key When the Create New Password window appears enter...

Страница 83: ...ng the new password appears directly press the Enter key the following dialog box appears select Yes User Password User password If you have set a user password you must enter the user password to ent...

Страница 84: ...Enter key 4 Enter the password again in the pop up confirmation window to confirm that the password is entered correctly To clear the user password follow the same steps as changing the user password...

Страница 85: ...d and Disabled Boot Option Priorities Boot priority options Network Device BBS Priorities Set the boot priority of the smart device Hard Drive BBS Priorities Set the boot priority of the storage drive...

Страница 86: ...llowing options 6 1 RAID function setting Motherboard with Intel C612 chip this motherboard can support the following SATA RAID solutions Intel The Rapid Storage Technology Enterprise Option ROM utili...

Страница 87: ...ten on the mirrored hard disk When the main hard disk physical is damaged the mirror hard disk will replace the main hard disk Because there are mirrored hard disks for data backup the data security o...

Страница 88: ...nto two groups which is regarded as the lowest combination of RAID 0 and then treats these two groups as RAID 1 respectively RAID 10 is also called mirrored array striping Like RAID 0 data is extracte...

Страница 89: ...capacity as much as possible Please follow the installation method below to construct a SATA RAID disk array 1 Follow the instructions to install the SATA hard drive into the hard drive bay 2 Connect...

Страница 90: ...2U Server Product Technical Manual 86 www qtech ru 2 Enter the Software Feature Mask Configuration item you can see that the motherboard RAID0 RAID1 RAID5 RAID10 are all set to Enabled and Intel Rapid...

Страница 91: ...e BIOS reboot and see the following prompt If the operating modes of the sSATA and SATA controllers are all set to RAID the prompt Press CTRL I to enter Configuration Utility will appear twice during...

Страница 92: ...Create RAID Volume Configures a RAID volume Delete RAID Volume Delete the RAID volume Reset Disks to Non RAID Clears the disk s RAID configuration information Mark Disks as Spare Configure the hot spa...

Страница 93: ...lume from the RSTe configuration page and press Enter Figure 1 16 RSTe configuration interface 3 Go to the page shown in Figure 1 17 Set parameters in the Name RAID Level Disks Strip Size and Capacity...

Страница 94: ...ks tab and press Enter Press SPACE to select the disk Strip Size Stripe size the size of the stripe data block written on each disk Capacity Logical disk capacity 4 Enter the interface shown in Figure...

Страница 95: ...Select the disk to be configured as a hot spare disk and press SPACE Then press Enter In the prompt box enter y and press Enter to complete the configuration of the hot spare disk Figure 1 20 Selectin...

Страница 96: ...RSTe configuration interface 2 As shown in Figure 1 22 select Delete RAID Volume from the RSTe configuration page and press Enter Figure 1 22 RSTe configuration interface 3 Enter the interface shown i...

Страница 97: ...6 2 LSI SAS3008 Group RAID Configuring RAID in UEFI Boot Mode Enter the RAID card configuration interface 1 During the server startup press Delete Esc as prompted to enter the BIOS Setup interface 2...

Страница 98: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 94 www qtech ru 4 Enter the RAID card configuration interface as shown in the following figure...

Страница 99: ...nstallation manual Qtech Platform 2U Server Product Technical Manual 95 www qtech ru Common tasks Create RAID 1 Select Create Configuration to enter the Configure RAID interface as shown in the follow...

Страница 100: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 96 www qtech ru 2 Enter the screen shown below select Select RAID Level set the RAID level and press Enter...

Страница 101: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 97 www qtech ru 3 Select Selcect Physical Disks to enter the RAID page of the selected group RAID...

Страница 102: ...ware installation manual Qtech Platform 2U Server Product Technical Manual 98 www qtech ru 4 Select the disk you want to use to configure the RAID Enabled is selected select Apply Changes and press En...

Страница 103: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 99 www qtech ru 5 Change Confirm to Enabled and select Yes to complete RAID configuration...

Страница 104: ...s larger than the capacity of a RAID single member disk used to contribute to the RAID The number of disks to be attached must be greater than the number of RAID groups Otherwise Manage Global Hotspar...

Страница 105: ...l Qtech Platform 2U Server Product Technical Manual 101 www qtech ru 2 Select the hot spare disk set the hot spare disk to Enabled select Assign Global Hotspare Disk and press enter to complete the ho...

Страница 106: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 102 www qtech ru Delete RAID 3 Select Virtual Disk Management and press enter...

Страница 107: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 103 www qtech ru 4 Select Select Virtual Disk Operations and press enter...

Страница 108: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 104 www qtech ru 5 Select Delete Virtual Disk and press enter...

Страница 109: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 105 www qtech ru 6 Change Confirm to Enabled check Yes and press enter to finish deleting RAID...

Страница 110: ...ation manual Qtech Platform 2U Server Product Technical Manual 106 www qtech ru Legacy boot mode to configure RAID 1 During the BIOS startup process as shown in Figure 2 1 press Ctrl C Figure 2 1 Ente...

Страница 111: ...nual 107 www qtech ru 2 Enter the interface shown in Figure 2 2 Please refer to the key operation hints at the bottom border of the interface to navigate and modify the settings in the interface Figur...

Страница 112: ...form 2U Server Product Technical Manual 108 www qtech ru 4 Select to enter the RAID Properties menu press enter enter the group raid interface as shown below can be in the current interface group raid...

Страница 113: ...anced AVAGO MegaRAID AVAGO MegaRAID SAS 91311 8i Configuration Utility and press Enter 3 As shown in Figure 3 1 five types of configuration tasks are displayed on the interface for details see Table 1...

Страница 114: ...he disk fails Hardware Components Select hardware components to view supercapacitor properties manage supercapacitors and manage peripheral components Common tasks Switch disk mode The RAID card suppo...

Страница 115: ...llation manual Qtech Platform 2U Server Product Technical Manual 111 www qtech ru 2 Enter the interface as shown in Figure 3 3 Select the disk to be configured and press Enter Figure 3 3 Drive Managem...

Страница 116: ...2U Server Product Technical Manual 112 www qtech ru 3 Enter the interface as shown in Figure 3 4 Select Operation and press Enter In the dialog box that is displayed select Make Unconfigured Bad and...

Страница 117: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 113 www qtech ru 4 Go to the screen shown in Figure 3 5 Select Go and press Enter Figure 3 5 Select Go...

Страница 118: ...installation manual Qtech Platform 2U Server Product Technical Manual 114 www qtech ru 5 Enter the interface shown in Figure 3 6 to complete the switch disk mode operation Figure 3 6 Complete Switch D...

Страница 119: ...ech Platform 2U Server Product Technical Manual 115 www qtech ru Create RAID 1 As shown in Figure 3 7 select Configuration Management on the RAID card configuration page and press Enter Figure 3 7 RAI...

Страница 120: ...tallation manual Qtech Platform 2U Server Product Technical Manual 116 www qtech ru 2 Enter the interface as shown in Figure 3 8 Select Create Virtual Drive and press Enter Figure 3 8 Select Create Vi...

Страница 121: ...tion manual Qtech Platform 2U Server Product Technical Manual 117 www qtech ru 3 Enter the interface as shown in Figure 3 9 Select Select RAID Level set the RAID level and press Enter Figure 3 9 Setti...

Страница 122: ...shown in Figure 3 10 Select Select Drives From set the RAID disk capacity source and press Enter Unconfigured Capacity Indicates that the capacity is from the remaining capacity of the configured RAI...

Страница 123: ...re installation manual Qtech Platform 2U Server Product Technical Manual 119 www qtech ru 5 Enter the interface as shown in Figure 3 11 Select Select Drives and press Enter Figure 3 11 Select Select D...

Страница 124: ...nual 120 www qtech ru 6 Enter the interface as shown in Figure 3 12 Select the disk to use for RAID configuration Enabled is selected select Apply Changes and press Enter If the status of the disk is...

Страница 125: ...r Product Technical Manual 121 www qtech ru 7 Enter the interface as shown in Figure 3 13 and perform the corresponding settings see Table 1 3 for parameter descriptions Then select Save Configuration...

Страница 126: ...e name of the RAID which only supports letters numbers and underscores It is case insensitive Virtual Drive Size RAID capacity size Virtual Drive Size Unit RAID capacity unit Stripe Size Stripe size t...

Страница 127: ...on Default initialization method Save Configuration Save the configuration created by the wizard Do not use special characters as the name of the RAID Read Ahead Write Back and Cached improve performa...

Страница 128: ...latform 2U Server Product Technical Manual 124 www qtech ru 9 Enter the screen shown in Figure 2 19 to complete the RAID configuration Select OK to return to the RAID card configuration interface Figu...

Страница 129: ...l Qtech Platform 2U Server Product Technical Manual 125 www qtech ru 10 As shown in Figure 3 15 select Virtual Drive Management from the RAID card configuration page and press Enter Figure 3 15 RAID c...

Страница 130: ...ch Platform 2U Server Product Technical Manual 126 www qtech ru 11 Enter the interface as shown in Figure 3 16 You can see the created RAID select the RAID to be viewed and press Enter Figure 3 16 Vit...

Страница 131: ...duct Technical Manual 127 www qtech ru 12 Enter the interface as shown in Figure 3 17 Select View Associated Drives and press Enter to view the details of the RAID including the RAID name level disk i...

Страница 132: ...ated hot spare disk as required Hot spares are used only for redundant RAID levels The capacity of a hot spare is greater than the capacity of a RAID single member disk to contribute to that RAID Only...

Страница 133: ...anual Qtech Platform 2U Server Product Technical Manual 129 www qtech ru 2 On the page shown in Figure 3 19 select the disk to be configured as a global hot spare disk and press Enter Figure 3 19 Driv...

Страница 134: ...al Qtech Platform 2U Server Product Technical Manual 130 www qtech ru 3 Go to the screen shown in Figure 3 20 Select Operation press Enter select Assign Dedicated Hot Spare Drive and press Enter Figur...

Страница 135: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 131 www qtech ru 4 Go to the screen shown in Figure 3 21 Choose Go and press Enter Figure 3 21 Select Go...

Страница 136: ...lation manual Qtech Platform 2U Server Product Technical Manual 132 www qtech ru 5 Enter the interface as shown in Figure 3 22 Select Confirm to enable it select Yes and press Enter Figure 3 22 Confir...

Страница 137: ...Qtech Platform 2U Server Product Technical Manual 133 www qtech ru 6 Go to the page shown in Figure 3 23 to complete the configuration of the global hot spare disk Figure 3 23 Complete configuration...

Страница 138: ...h Platform 2U Server Product Technical Manual 134 www qtech ru Delete RAID 1 As shown in Figure 3 24 select Virtual Drive Management from the RAID card configuration page and press Enter Figure 3 24 R...

Страница 139: ...manual Qtech Platform 2U Server Product Technical Manual 135 www qtech ru 2 Enter the interface as shown in Figure 3 25 Select the logical disk to be deleted and press Enter Figure 3 25 Logical Disk...

Страница 140: ...2U Server Product Technical Manual 136 www qtech ru 3 Enter the interface as shown in Figure 2 37 Select Operation and press Enter In the dialog box that is displayed select Delete Virtual Drive and...

Страница 141: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 137 www qtech ru 4 Go to the screen shown in Figure 2 38 Choose Go and press Enter Figure 2 38 Select Go...

Страница 142: ...re installation manual Qtech Platform 2U Server Product Technical Manual 138 www qtech ru 5 Enter the interface as shown in Figure 2 39 Choose Confirm Enabled Yes and press Enter Figure 2 39 Confirm D...

Страница 143: ...dware installation manual Qtech Platform 2U Server Product Technical Manual 139 www qtech ru 6 Enter the interface as shown in Figure 2 40 to delete the RAID operation Figure 2 40 Complete RAID Deleti...

Страница 144: ...2U Server Product Technical Manual 140 www qtech ru Locate the disk location 1 Locating physical disks 1 1 As shown in Figure 2 41 select Drive Management from the RAID card configuration page and pre...

Страница 145: ...nstallation manual Qtech Platform 2U Server Product Technical Manual 141 www qtech ru 1 2 Enter the Figure 2 42 interface Select the disk to be located and press Enter Figure 2 42 Selecting a disk to...

Страница 146: ...Platform 2U Server Product Technical Manual 142 www qtech ru 1 3 Go to the Figure 2 43 interface Choose Operation and press Enter In the dialog box that is displayed select Start Locate and press Ent...

Страница 147: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 143 www qtech ru 1 4 Go to the Figure 2 44 screen Choose Go and press Enter Figure 2 44 Select Go...

Страница 148: ...ation manual Qtech Platform 2U Server Product Technical Manual 144 www qtech ru 1 5 Go to the Figure 2 45 interface to complete the location of the physical disk Figure 2 45 Positioning the physical d...

Страница 149: ...Server Product Technical Manual 145 www qtech ru 2 Locating all disks in a logical disk 2 1 As shown in Figure 2 41 select Virtual Drive Management from the RAID card configuration page and press Ente...

Страница 150: ...tion manual Qtech Platform 2U Server Product Technical Manual 146 www qtech ru 2 2 Go to the Figure 2 47 screen Select the logical disk to be located and press Enter Figure 2 47 Selecting a logical di...

Страница 151: ...Platform 2U Server Product Technical Manual 147 www qtech ru 2 3 Enter the Figure 2 48 interface Select Operation and press Enter In the dialog box that is displayed select Start Locate and press Ent...

Страница 152: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 148 www qtech ru 2 4 Go to the screen shown in Figure 2 49 Choose Go and press Enter Figure 2 49 Select Go...

Страница 153: ...form 2U Server Product Technical Manual 149 www qtech ru 2 5 Enter the Figure 2 50 interface to complete the operations for locating all the disk locations in the logical disk Figure 2 50 Complete pos...

Страница 154: ...alize the logical disk This function is used to initialize the logical disk internal data space so that it can be used by the operating system 1 As shown in Figure 2 51 select Virtual Drive Management...

Страница 155: ...anual Qtech Platform 2U Server Product Technical Manual 151 www qtech ru 2 Enter the interface as shown in Figure 2 52 Select the logical disk to be initialized and press Enter Figure 2 52 Logical Dis...

Страница 156: ...m 2U Server Product Technical Manual 152 www qtech ru 3 Go to the screen shown in Figure 2 53 Select Operation and press Enter In the dialog box that is displayed select Fast Slow Initialization and p...

Страница 157: ...u The difference between Fast Initialization and Slow Initialization is that the former can write data immediately and the latter can wait for the disk space to be completely initialized before writin...

Страница 158: ...installation manual Qtech Platform 2U Server Product Technical Manual 154 www qtech ru 5 Enter the interface shown in Figure 2 55 Select Confirm Enabled Yes and press Enter Figure 2 55 Confirm initia...

Страница 159: ...al Qtech Platform 2U Server Product Technical Manual 155 www qtech ru 6 Enter the interface shown in Figure 2 56 to complete the initialization of logical disk operations Figure 2 56 complete initiali...

Страница 160: ...atform 2U Server Product Technical Manual 156 www qtech ru Initialize the physical disk 1 As shown in Figure 2 57 select Drive Management from the RAID card configuration page and press Enter Figure 2...

Страница 161: ...tallation manual Qtech Platform 2U Server Product Technical Manual 157 www qtech ru 2 Enter the screen shown in Figure 2 58 Select the disk to be initialized and press Enter Figure 2 58 Disk Managemen...

Страница 162: ...rm 2U Server Product Technical Manual 158 www qtech ru 3 Go to the Figure 2 59 interface Select Operation and press Enter In the dialog box that is displayed select Initialize Drive and press Enter Fi...

Страница 163: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 159 www qtech ru 4 Go to the Figure 2 60 screen Choose Go and press Enter Figure 2 60 Select Go...

Страница 164: ...llation manual Qtech Platform 2U Server Product Technical Manual 160 www qtech ru 5 Enter the interface shown in Figure 2 61 Select Confirm to enable it select Yes and press Enter Figure 2 61 Confirm...

Страница 165: ...manual Qtech Platform 2U Server Product Technical Manual 161 www qtech ru 6 Enter the Figure 2 62 interface to complete the initialization of the physical disk operation Figure 2 62 Complete initializ...

Страница 166: ...isk data This function is used to delete internal data of the disk including erasing physical disk data and logical disk data 1 Erase physical disk data 1 1 As shown in Figure 2 63 select Drive Manage...

Страница 167: ...nstallation manual Qtech Platform 2U Server Product Technical Manual 163 www qtech ru 1 2 Enter the screen shown in Figure 2 64 select the disk to be erased and press Enter Figure 2 64 Disk Management...

Страница 168: ...orm 2U Server Product Technical Manual 164 www qtech ru 1 3 Enter the interface as shown in Figure 2 65 Select Operation and press Enter In the dialog box that is displayed select Drive Erase and pres...

Страница 169: ...2U Server Product Technical Manual 165 www qtech ru 1 4 Go to the screen shown in Figure 2 66 press Enter and then select the erase mode in the dialog box that is displayed the default mode is recomm...

Страница 170: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 166 www qtech ru 1 5 Go to the screen shown in Figure 2 67 Choose Go and press Enter Figure 2 67 Select Go...

Страница 171: ...tallation manual Qtech Platform 2U Server Product Technical Manual 167 www qtech ru 1 6 Enter the interface as shown in Figure 2 68 Select Confirm to enable it select Yes and press Enter Figure 2 68 C...

Страница 172: ...lation manual Qtech Platform 2U Server Product Technical Manual 168 www qtech ru 1 7 Enter the interface as shown in Figure 2 69 to finish erasing physical disk data Figure 2 69 Finishing Erasing Phys...

Страница 173: ...ww qtech ru To avoid disk failure do not perform other operations while erasing physical disk data 2 Erase logical disk data 2 1 As shown in Figure 2 70 select Virtual Drive Management from the RAID c...

Страница 174: ...manual Qtech Platform 2U Server Product Technical Manual 170 www qtech ru 2 2 Enter the interface as shown in Figure 2 71 Select the logical disk to be erased and press Enter Figure 2 71 Logical Disk...

Страница 175: ...orm 2U Server Product Technical Manual 171 www qtech ru 2 3 Enter the page shown in Figure 2 72 Select Operation and press Enter In the dialog box that is displayed select Virtual Drive Erase and pres...

Страница 176: ...2U Server Product Technical Manual 172 www qtech ru 2 4 Enter the interface shown in Figure 2 73 press Enter and then select the erase mode in the dialog box that is displayed The default mode Simple...

Страница 177: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 173 www qtech ru 2 5 Go to the interface shown in Figure 2 74 Choose Go and press Enter Figure 2 74 Select Go...

Страница 178: ...tallation manual Qtech Platform 2U Server Product Technical Manual 174 www qtech ru 2 6 Enter the interface as shown in Figure 2 75 Select Confirm to enable it select Yes and press Enter Figure 2 75 C...

Страница 179: ...installation manual Qtech Platform 2U Server Product Technical Manual 175 www qtech ru 2 7 Enter the interface as shown in Figure 2 76 to erase logical disk data Figure 2 76 Complete erase logical di...

Страница 180: ...ID levels This function is used to modify the RAID level to meet the configuration requirements without affecting the integrity of the current data 1 As shown in Figure 2 77 select Virtual Drive Manag...

Страница 181: ...manual Qtech Platform 2U Server Product Technical Manual 177 www qtech ru 2 Enter the interface as shown in Figure 2 78 Select the logical disk to be rebuilt and press Enter Figure 2 78 Virtual Drive...

Страница 182: ...2U Server Product Technical Manual 178 www qtech ru 3 Enter the screen shown in Figure 2 79 Select Operation and press Enter In the dialog box that is displayed select Reconfigure Virtual Drive and p...

Страница 183: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 179 www qtech ru 4 Go to the screen shown in Figure 2 80 Choose Go and press Enter Figure 2 80 Select Go...

Страница 184: ...nstallation manual Qtech Platform 2U Server Product Technical Manual 180 www qtech ru 5 Enter the screen shown in Figure 2 81 Set the RAID level select Add Drives and press Enter Figure 2 81 Advanced...

Страница 185: ...manual Qtech Platform 2U Server Product Technical Manual 181 www qtech ru 6 Enter the screen shown in Figure 2 82 Select the disk to be added enable it select Apply Changes and press Enter Figure 2 82...

Страница 186: ...lation manual Qtech Platform 2U Server Product Technical Manual 182 www qtech ru 7 Enter the interface as shown in Figure 2 83 Select Confirm to enable it select Yes and press Enter Figure 2 83 Confir...

Страница 187: ...are installation manual Qtech Platform 2U Server Product Technical Manual 183 www qtech ru 8 Go to the screen shown in Figure 2 84 Select Start Operation and press Enter Figure 2 84 Start Operation sc...

Страница 188: ...Hardware installation manual Qtech Platform 2U Server Product Technical Manual 184 www qtech ru 9 Go to the screen shown in Figure 2 85 Choose OK and press Enter Figure 2 85 Select OK...

Страница 189: ...stallation manual Qtech Platform 2U Server Product Technical Manual 185 www qtech ru 10 Enter the interface as shown in Figure 2 86 to check the current migration progress Figure 2 86 RAID information...

Страница 190: ...sidue information in the disk so that the disk can be reused to configure RAID This feature is commonly used for disks with the mode Unconfigured Bad 1 Switch the disk mode Unconfigured Bad to Unconfi...

Страница 191: ...ion manual Qtech Platform 2U Server Product Technical Manual 187 www qtech ru 3 Go to the screen shown in Figure 2 88 Select Manage Foreign Configuration and press Enter Figure 2 88 Select Manage Fore...

Страница 192: ...ion manual Qtech Platform 2U Server Product Technical Manual 188 www qtech ru 4 Enter the interface shown in Figure 2 89 Select Clear Foreign Configuration and press Enter Figure 2 89 Select Clear For...

Страница 193: ...rdware installation manual Qtech Platform 2U Server Product Technical Manual 189 www qtech ru 5 Enter the screen shown in Figure 2 90 Select Confirm Enabled Yes and press Enter Figure 2 90 Confirm Cle...

Страница 194: ...tallation manual Qtech Platform 2U Server Product Technical Manual 190 www qtech ru 6 Enter the screen shown in Figure 2 91 to complete the disk RAID disk clearing operation Figure 2 91 Clear Disk RAI...

Страница 195: ...er Product Technical Manual 191 www qtech ru Legacy boot mode to configure RAID Enter the RAID card configuration interface 1 During the BIOS startup process as shown in Figure 2 92 press Ctrl R Figur...

Страница 196: ...ace shown in Figure 2 93 Please refer to the key operation tips at the bottom border of the interface to navigate and modify the settings in the interface Figure 2 93 LSI RAID Management Interface Com...

Страница 197: ...93 www qtech ru Figure 2 94 Select Create Virtual Drive 2 Go to the screen shown in Figure 2 95 Set the RAID level and press Enter Figure 2 95 Setting RAID Level 3 Enter the screen shown in Figure 2 9...

Страница 198: ...e screen shown in Figure 2 97 Set the Size and Name accordingly Then choose Advanced and press Enter Figure 2 97 Setting the RAID Name and Capacity 5 Enter the page shown in Figure 2 98 Set related pa...

Страница 199: ...as shown in Figure 2 99 Choose OK and press Enter to complete the RAID configuration Figure 2 99 Confirm Create 7 Select the RAID to be viewed and press Enter to view the detailed information of the R...

Страница 200: ...re disk as required Hot spares are used only for redundant RAID levels The capacity of a hot spare is greater than the capacity of a RAID single member disk to contribute to that RAID Only disks with...

Страница 201: ...Figure 2 102 select Make Global HS and press Enter to complete the configuration of the global hot spare disk Figure 2 102 Selecting Make Global HS 1 3 Return to the screen shown in Figure 2 103 Sele...

Страница 202: ...s function is used to delete RAID that is damaged or hard to meet the requirements 1 As shown in Figure 2 104 select the logical disk to be deleted on the VD Mgmt screen and press F2 Figure 2 104 Sele...

Страница 203: ...ech Platform 2U Server Product Technical Manual 199 www qtech ru Figure 2 105 Select Delete VD 3 Enter the screen shown in Figure 2 106 Select YES and press Enter to complete the RAID operation Figure...

Страница 204: ...the corresponding slot of the disk You can locate a single physical disk or all member disks included in a logical disk 1 As shown in Figure 2 107 select the disk to be located on the PD Mgmt screen...

Страница 205: ...tion Locate Stop Stops locating disk operations Initialize the logical disk This function is used to initialize the internal data space of the disk so that it can be used by the operating system 1 As...

Страница 206: ...u 2 Go to the interface shown in Figure 2 110 and select Initialization Start FGI Figure 2 110 Select Initialization Start FGI BGI Backgroud Initialization background initialization initializing some...

Страница 207: ...wn in Figure 2 111 Select YES and press Enter to complete the initialization of the disk operation Figure 2 111 Confirming the initialization Erase disk data This function is used to delete internal d...

Страница 208: ...u 1 2 Enter the interface as shown in Figure 2 113 Select the erase mode use the default mode Simple and press Enter Figure 2 113 Select the erase mode 1 3 Enter the interface shown in Figure 2 114 Se...

Страница 209: ...5 www qtech ru To avoid disk failure do not perform other operations while erasing physical disk data 2 Erase logical disk data 2 1 As shown in Figure 2 115 select the logical disk to be erased on the...

Страница 210: ...qtech ru 2 2 Enter the interface as shown in Figure 2 116 Select the erase mode use the default mode Simple and press Enter Figure 2 116 Selecting the erase mode 2 3 Enter the interface as shown in Fi...

Страница 211: ...residue information in the disk so that the disk can be reused to configure RAID This feature is commonly used for disks that have the Unconfigured Bad mode 1 Switch the disk mode Unconfigured Bad to...

Страница 212: ...ual Qtech Platform 2U Server Product Technical Manual 208 www qtech ru 3 In the dialog box that is displayed in Figure 2 119 select OK and press Enter to complete the disk RAID information operation F...

Страница 213: ...Process Make sure the motherboard supports IPMI functionality Check your motherboard specification and confirm that your motherboard supports IPMI then find the dedicated IPMI network port on the mot...

Страница 214: ...the Server Mgmt option and you will see the page shown in Figure 2 5 Figure 2 5 Server Mgmt interface After entering the interface enter the BMC network configuration option through the keyboard The f...

Страница 215: ...allation manual Qtech Platform 2U Server Product Technical Manual 211 www qtech ru As shown in the picture above we move the cursor to the configuration Address source menu and click Enter to enter th...

Страница 216: ...teps we can start to log in to the IPMI management interface The IPMI management interface can be accessed using a standard web browser Here we recommend Google Chrome browser Firfox Firefox browser a...

Страница 217: ...rm in real time including the sensor name the sensor reading the real time curve change of the sensor reading and the state of the alarm 2 Sensor This page shows the status of all sensors When there i...

Страница 218: ...ce You can perform basic maintenance operations on the server such as BMC firmware updates and BIOS firmware updates 12 Logout Click to log off the current user s login KVM Remote Management Introduct...

Страница 219: ...3 8 SOL login page This page will ask you to enter BMC IP Username Password and baud rate related parameters The BMC IP is the IPMI IP that you configured above The Username and Password are factory d...

Страница 220: ...l com content www us en servers ipmi ipmi technical resources html With Windows Server 2003 R2 Microsoft also provides IPMI driver packages You can also use the Open IPMI driver in the system The AST2...

Страница 221: ...m 2U Server Product Technical Manual 217 www qtech ru The above documents are designed to help you to quickly understand and deploy the system s IPMI functionality Detailed IPMI operation manuals are...

Отзывы: