Page | 14
To Supply Water to the 1” NPSH Discharge
1
. Connect your hose fitting to the 1” NPSH discharge outlet.
2. Lay out the hose, open the discharge valve slowly (
Figure 2
) to charge the line and
supply water to the nozzle.
STOPPING YOUR QTAC
1. If opened, gradually close the shut-off valve at the end of the discharge hose
2. Decrease the throttle on the pump engine to the idle position (
Figure 3
).
3. Set the engine switch to the “OFF” position (
Figure 3
)
STORING YOUR QTAC
General Storage
• Drain the fuel from the pump engine carburetor and fuel tank. See the Engine
Owner’s Manual for additional details.
• Drain any water from the water tank by opening all the valves, and the water tank
drain port (
Figure 1
)
• Drain the water from the pump by opening the pump drain port (
Figure 2
) See the
pump Instruction Manual for additional details.
NOTE:
If your QTAC will be subjected to below freezing temperatures, ensure
that all water is drained from the water tank, pumping system, and hoses. Store
with all valves in the open position. If you would like to keep water in your QTAC
in below freezing temperatures, make sure to add an appropriate amount of RV
antifreeze to the water to prevent the formation of ice.