background image

16

Operation

 QSControl Port

The QSControl port operates on a 10BaseT Ethernet network. This port is one of the primary means for connecting QSControl.net to the 
DSP 322ua. The port may connect directly to a PC's 10BaseT or 10/100 (auto-sensing or auto-negotiating) network interface card using 
a crossover cable. Data from the QSControl port may also pass through network repeaters, network switches and routers. We strongly 
recommend the use of network switches to facilitate higher bandwidth and dedicated connections.

1 Minute Autosave Timer and Power Cycling 

The active configuration has a special feature associated with it. Any changes made to a parameter during operation will start an inter-
nal timer which will trigger an automatic save of the configuration data. The save procedure begins after 1 minute of parameter change 
inactivity. If the DSP322ua is then power cycled, upon restart, the previous settings data will be preserved in the active configuration. 

Utility/Diagnostic Functions

Safe Mode Switch

Location of Safe Mode switch:

 The front panel has a small access hole on the left side, just left of the Power indicator. It is not 

labeled to help prevent accidental use. The Safe Mode switch can be operated by using a paperclip (or similar item) inserted into the 
access hole and pushing. 

Safe Mode: Use if the DSP 322ua becomes inoperable (or behaves in completely unexpected ways) after updating firm-

ware.

If the DSP 322ua operates in an unexpected way or is not responding to any communications after a new firmware file is uploaded to it, 
it is likely the file was corrupted during transfer. If this occurs, there is a “backup” program in the DSP 322ua that will enable you to 
communicate with it.

How to put the DSP 322ua into Safe Mode:

1-

 

Turn off the power to the DSP 322ua by unplugging it from the AC outlet.

2-

 

Depress the Safe Mode switch and keep it depressed while plugging the unit back in (power on).

3-

 The DSP 322ua is now in “safe mode”. You may release the switch.

You should now be able to re-establish limited TCP/IP communications with the DSP 322ua. Once communication has been re-estab-
lished, the file transfer can be tried again or the old application file used until the source of the data transfer problem can be found. 
Also, QSControl.net WILL NOT communicate with the DSP 322ua if it is in “safe mode”. You may communicate only using TFTP, Telnet, 
or RS-232.

RS-232 Serial Port I/O Interface

The RS-232 connector on the rear panel is used as a serial port input/output (I/O). This I/O port is used for accessing Ethernet/IP set-
tings, stand alone control capabilities, system “health” data, firmware version information and other related data.

Should any system problems arise, the data that may be accessed through this interface can help to track down the problem. The most 
common items that might be used are “Display Network Settings” and “Enter Network Setup”. Many of the remaining selections would 
typically be used for troubleshooting purposes along with a QSC technical representative prompting you to access particular menu 
items so the data can be interpreted.

Connection is made using a normal serial cable between your computer’s serial port and the RS-232 port of the DSP 322ua. Once prop-
erly connected, a “dumb-terminal” program (such as

 Hyper Terminal

, a widely used version on most Windows-based PC’s) is started and 

communication established between the PC and the DSP 322ua. 

Following is the basic procedure for starting up 

Hyper Terminal,

 naming the connection, specifying the communications settings and an 

example of “what you should see” for a text-menu once the communications link has been established. If programs other than

 Hyper 

Terminal 

are used, you will need to follow your software’s instructions for establishing communications through your PC’s COM (serial) 

port.

Содержание DSP 322UA

Страница 1: ...TD 000199 00 rev A TD 000199 00 DSP 322ua 8x8 Signal Processor Hardware Manual...

Страница 2: ...ord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE S...

Страница 3: ...everal computers roaming wireless laptops tablets etc all at the same time from anywhere a connection to the QSControl net network is available The QSControl net network can also be managed from a sin...

Страница 4: ...bilities to QSControl net Our latest code releases and access to up to date information on QSControl net are available at www qscontrol net We invite you to visit us there We are confident that your n...

Страница 5: ...our DSP 322ua should not be installed on the same LAN or virtual LAN VLAN with distributed audio and or video services While coexistence with conventional data communications services is tolerated to...

Страница 6: ...normal networking principles apply Here all QSCon trol net traffic resides on a single unmanaged Ethernet switch The DSP 322ua connects directly to the switch A computer hosting a QSControl net serve...

Страница 7: ...ourced The figure shows a separate VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This configuration essentially provides a dedicated network for QSControl net including...

Страница 8: ...pment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack moun...

Страница 9: ...n settings should be set to Never This avoids waiting for the system to wake up if adjustment is needed after an elapsed period of time To Install QSControl net 1 Start your computer and start Windows...

Страница 10: ...Audio Outputs Eight balanced audio inputs are provided CH 1 OUTPUT CH 8 OUTPUT Plug the output signal terminal block connectors into the output receptacles Connection pin out is printed on the rear l...

Страница 11: ...unctioning AC outlet it will power up and briefly display a welcome screen on the LCD dis play POWER Indicator This blue indicator illuminates when the DSP 322ua is plugged into a properly functioning...

Страница 12: ...and accepting choices entering by pushing in on the control The accessible menus and sub menus may appear differently than the example shown Software updates may occasionally improve the interface Th...

Страница 13: ...creen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow characters indicate right side button context If additional menus are available the arr...

Страница 14: ...fy the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Select...

Страница 15: ...nnections verify IP addresses are set correctly verify Subnet masks are set cor rectly and verify AC power is properly applied to the DSP 322ua 19 Click the sign of the DSP 322ua in the inventory root...

Страница 16: ...g it from the AC outlet 2 Depress the Safe Mode switch and keep it depressed while plugging the unit back in power on 3 The DSP 322ua is now in safe mode You may release the switch You should now be a...

Страница 17: ...ompt for the DSP 322ua A text menu will appear This is sent by the DSP 322ua and will detail your options and instructions for changing the address information From this main menu you will need to mak...

Страница 18: ...ut 1 2 3 CHASSIS GND Input Impedance nom Balanced 6 81k ohms Unbalanced 13 6k ohms Common Mode Rejection 20Hz 20KHz min 54dB 20Hz 20KHz typ 60dB E I N max 150 ohm 30dB 124 5dBu150 ohm 60dB 125 0 dBu I...

Страница 19: ...chable terminal blocks Configuration Single ended ground referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation Use 10K for full r...

Страница 20: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Отзывы: