Introduction

Thank you and congratulations on your purchase of the QSC DCM Digital Cin-
ema Monitor. This product represents the state-of-the-art for cinema-based 
signal processing and monitoring functions in a single, integrated system. 
Designed to compliment QSC’s DCA (Digital Cinema Amplifier) Series and DCS 
(Digital Cinema Speaker) Series  products, the DCM optimizes loudspeaker per-
formance while facilitating easy cinema sound system wiring and configura-
tion. To get the most from your investment, we encourage you to review this 
manual carefully.

The QSC DCM provides a wealth of signal processing functions with the ability 
to copy and transfer settings—resulting in fast system setup time in multiplex 
theaters where multiple rooms share similar characteristics. Providing both 
monitor and crossover functions in a single unit, the DCM is capable of simple 
crossover adjustments via a personal computer (PC). These modifications can 
be password protected for tamper-proof system control.

Fast Setup with Easy Wiring

Your DCM takes advantage of the unique DataPort found on DCA Series ampli-
fiers and thus greatly simplifies system wiring—reducing installation and labor 
costs in the process. A single VGA-style cable per amplifier channel pair con-
tains two input signals, two return signals, power on/standby control, and two 
channels of load monitoring.

The included PC configuration software further enhances the DCM setup. This software includes a database that lists the default parameters for pop-
ular cinema loudspeaker models. Commonly used configurations can be saved to disk, facilitating the easy transfer of settings to other DCMs.

Advanced Monitoring Control

In addition to the monitoring of your amplifier’s audio I/O, your DCM includes QSC’s exclusive “Load Fault” detection feature. The DCM monitors for 
possible loudspeaker system or wiring faults and notifies you via LED Load Fault indicators.

System Requirements

DCM Manager software is designed to control one DCM hardware unit at a time. To use this software with the DCM hardware unit, you must have 
the following:

1-

 Digital Cinema Monitor unit

2- 

DCM Manager 2007 software installation CD

3- 

IBM-compatible PC with a 1 GHz Pentium 4 processor (or better)

Windows XP or VISTA operating system
Microsoft® Internet Explorer
Minimum of 512 MB of RAM
Minimum of 500 MB of available hard disk storage space
CD-ROM drive
Display resolution of 1024 x 768, 16 colors minimum
USB port

To complete your Cinema System, you will also need a cinema processor, QSC Audio’s DCA amplifiers, loudspeakers, and necessary cables.

Unpacking

The DCM is highly durable and carefully packaged. We recommend you inspect the unit carefully after removing it from the packaging, as occasion-
ally there may be damage due to some unfortunate incident during shipment. Report any damage to the shipping carrier. We recommend saving the 
carton and packing material in case the unit must be shipped back to your dealer, distributor, or service center. Also note: some freight companies 
consider damage claims without the original packing materials invalid.

The QSC shipping box should contain:

1-

 the DCM unit

2-

 this owner’s manual

3- 

AC power cord, IEC-type, 18 AWG, 6 feet long, 120V

4- 

warranty card

5-

 DCM Manager Application Disk

Table 1: Supported Formats By Model

Format

DCM 10 

DCM 10D

DCM 30 

DCM 30D

6 Channel Passive

Yes

No

6 Channel Bi-Amp

Yes

Yes

6 Channel Tri-Amp

No

Yes

6 Channel Quad-Amp

No

Yes

8 Channel Bi-Amp

No

Yes

8 Channel Tri-Amp

No

Yes

8 Channel Quad-Amp

No

Yes

Surround-EX

Yes

Yes

Содержание DCM 10

Страница 1: ...DCM Series Digital Cinema Monitor Crossover System User Manual DCM 10 DCM 10D DCM 30 DCM 30D TD 000265 00 TD 000265 00 A...

Страница 2: ...or moisture does not operate normally or has been dropped 15 When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions may be created by an uneven weight distri...

Страница 3: ...circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or TV technician for help THIS PRODUCT IS INTENDED FOR CONNECTION TO A TN OR IT POWER SYSTEM S...

Страница 4: ...ng Control In addition to the monitoring of your amplifier s audio I O your DCM includes QSC s exclusive Load Fault detection feature The DCM monitors for possible loudspeaker system or wiring faults...

Страница 5: ...he signal from analog to digital and back again which is designed to minimize all background noise and react to the dynamic range of any film track 4 Loudspeaker Database pre programmed settings QSC h...

Страница 6: ...Monitor Loudspeaker On the rear panel are a set of screw terminals marked EXTERNAL SPKR These are for connection to an external monitor loudspeaker As shipped from the factory a jumper between the IN...

Страница 7: ...4 Subwoofer output 5 Alternate equalization select input 6 Auxiliary audio input 7 Hearing impaired output 8 Emergency bypass level controls and switch 9 Main analog input from cinema processor 10 Ana...

Страница 8: ...ermines the function of the Monitoring Select but tons to the right of the AMPS PROC button The LEDs directly over the AMPS PROC button indicate what selected function the Monitor Select buttons will...

Страница 9: ...t on all amplifier outputs To sense real world conditions these measurements must be found to be out of range several times before the Load Fault condition is indicated on the front panel If you are s...

Страница 10: ...io power INPUT SELECT Switch Use this switch to select the input source of the DCM In the ANALOG position input is from the MAIN ANALOG INPUT and the SURROUND EX INPUT if this option is installed If t...

Страница 11: ...nal to the EXTERNAL SPKR terminal SUB OUT provides the identical audio as the subwoofer DataPort This connection cannot be monitored or include any of the Fault Analysis functions because there are no...

Страница 12: ...chassis and rack can be damaged if the DCM is not properly supported Unless the DCM is being installed in its final fixed location QSC strongly recommends supporting the rear of the unit Rear rack ear...

Страница 13: ...ettings to the DCM hardware s flash memory and the DCM hardware can be disconnected from the host PC NOTE QSC updates these files regularly as new models are introduced from loudspeaker manufacturers...

Страница 14: ...operating voltage information printed on it Locate the sticker note the rated voltage and ensure the AC circuit you intend to use is properly rated Locate the IEC style AC power cord supplied with yo...

Страница 15: ...Ch 1 and Subcode 1 4 I MON Ch 1 and Subcode 2 5 Clip Protect Ch 1 6 Hard Ground 7 Ch 1 Plus Signal 8 Ch 2 Plus Signal 9 15V from Amplifier 10 Data Reference Ground 11 Ch 2 Minus Signal 12 Amplifier I...

Страница 16: ...Description 1 not used 2 not used 3 Back Surround Left 4 not used 5 not used 6 Back Surround Right 7 Ground Digital Inputs 8 not used 9 Right Extra 10 Surround Left 11 Surround Right 12 not used 13 no...

Страница 17: ...T 22 AES4 Bsl Bsr OUT 23 AES2 C SW OUT 24 AES2 C SW OUT 25 Chassis Ground Hearing Impaired The Hearing Impaired output signal is available on the screw terminal connector on the rear of the DCM The ou...

Страница 18: ...oise pick up than unbalanced connections External Speaker Connection The monitor signal is available on the screw terminals at the rear of the DCM This pow ered signal can be connected directly to an...

Страница 19: ...to the sound while in the Bypass position While in the bypassed position adjust the potentiometers to most closely match the normal position sound 3 Monitoring audio mix adjustments The DCM Manager s...

Страница 20: ...audible but all attempts to get it louder fail connect the DCM to a PC running DCM Manager software and check the Monitor Attenuation Levels settings on the Monitor Setting page These settings have a...

Страница 21: ...f switching the BYPASS to EMERGENCY does not restore sound to the center channel Verify the DCM is receiving input signals from the Cinema Processor Verify connections from the Cinema Processor to the...

Страница 22: ...0 01 Analog in 0 008 Digital in 20 Hz to 20 kHz all filters flat Frequency Response 20 Hz to 20 kHz D to A Conversion 24 bit delta sigma 128x oversampled Filter Topology 24 bit digital IIR Crossover...

Страница 23: ...Dimensions 19 wide x 5 25 high x 15 deep Weight 16 5 lbs 7 2 kg Line Voltage 100 VAC 240 VAC 50 60 Hz Safety Agency Approvals UL 60950 1 CSA RoHS WEE IEC 60950 1 EMC Approvals FCC Class B Connectors...

Страница 24: ...ions via pre paid transportation with a copy of proof of purchase i e sales receipt This warranty provides that the examination of the return product must indicate in our judgment a manufacturing defe...

Отзывы: