Connections (continued)

DataPort

The QSC DataPort connection carries input signals, amplifier 
output monitoring signals, remote amplifier power on/
standby control, amplifier temperature, and more, all on one 
cable.  Each DataPort is clearly marked indicating which 
channel’s amplifier it should be connected to. Follow the 
back panel labelling. Connect each DataPort to its respective 
amplifier’s DataPort. Finger-tighten the retaining screws on 
the cable connectors; do not overtighten!

Connect a DataPort cable from each of the DCM’s DataPorts 
to each of the system’s DCA amplifiers.

Orient the cable’s HD15 male connector properly and push 
the connector onto the DCA’s receptacle. Finger-tighten the 
retaining screws to ensure reliable connection. Connect the 
other end of the cable to the DataPort on the corresponding 
channel’s DCA amplifier.

DataPort Pinout

Configuration: 15-pin SubD (high-density) male to 15-pin 
SubD (high-density) male.

Pin #

Signal Description

1

Ch. 1 Minus (-) Signal

2

AC Standby Control

3

V- MON Ch. 1 and Subcode 1

4

I- MON Ch. 1 and Subcode 2

5

Clip/Protect Ch. 1

6

Hard Ground

7

Ch. 1 Plus (+) Signal

8

Ch. 2 Plus (+) Signal

9

+15V from Amplifier

10

Data Reference Ground

11

Ch. 2 Minus (-) Signal

12

Amplifier IDR (Model ID)

13

V- MON Ch. 2 and Subcode 3

14

I- MON Ch. 2 and Subcode 4

15

Clip/Protect Ch. 2

Use QSC DataPort cables. Contact QSC’s Technical Services Group if you would like to purchase standard length 
DataPort cables or specially made custom length cables that use shielded audio-pairs for the best possible perfor-
mance.

Cinema Processor Connection

Audio signals are input to the DCM via the Main Analog Input, Surround EX Input or Digital Input connections. These DB25-type connec-
tions conform to cinema industry standard pinout. Most common cinema processors use this DB25 connection standard, making connec-
tion to the DCM simple. Orient the DB25-type connector properly, push gently to seat the pins, then finger-tighten the retaining screws. 

Cinema processors that do not use standard DB25-type connection typically have adapter cables available. Check with the processor 
manufacturer. We recommended that you purchase a standard 25-pin cable from any of the well known cinema industry cable suppliers.

Содержание DCM 10

Страница 1: ...DCM Series Digital Cinema Monitor Crossover System User Manual DCM 10 DCM 10D DCM 30 DCM 30D TD 000265 00 TD 000265 00 A...

Страница 2: ...or moisture does not operate normally or has been dropped 15 When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions may be created by an uneven weight distri...

Страница 3: ...circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or TV technician for help THIS PRODUCT IS INTENDED FOR CONNECTION TO A TN OR IT POWER SYSTEM S...

Страница 4: ...ng Control In addition to the monitoring of your amplifier s audio I O your DCM includes QSC s exclusive Load Fault detection feature The DCM monitors for possible loudspeaker system or wiring faults...

Страница 5: ...he signal from analog to digital and back again which is designed to minimize all background noise and react to the dynamic range of any film track 4 Loudspeaker Database pre programmed settings QSC h...

Страница 6: ...Monitor Loudspeaker On the rear panel are a set of screw terminals marked EXTERNAL SPKR These are for connection to an external monitor loudspeaker As shipped from the factory a jumper between the IN...

Страница 7: ...4 Subwoofer output 5 Alternate equalization select input 6 Auxiliary audio input 7 Hearing impaired output 8 Emergency bypass level controls and switch 9 Main analog input from cinema processor 10 Ana...

Страница 8: ...ermines the function of the Monitoring Select but tons to the right of the AMPS PROC button The LEDs directly over the AMPS PROC button indicate what selected function the Monitor Select buttons will...

Страница 9: ...t on all amplifier outputs To sense real world conditions these measurements must be found to be out of range several times before the Load Fault condition is indicated on the front panel If you are s...

Страница 10: ...io power INPUT SELECT Switch Use this switch to select the input source of the DCM In the ANALOG position input is from the MAIN ANALOG INPUT and the SURROUND EX INPUT if this option is installed If t...

Страница 11: ...nal to the EXTERNAL SPKR terminal SUB OUT provides the identical audio as the subwoofer DataPort This connection cannot be monitored or include any of the Fault Analysis functions because there are no...

Страница 12: ...chassis and rack can be damaged if the DCM is not properly supported Unless the DCM is being installed in its final fixed location QSC strongly recommends supporting the rear of the unit Rear rack ear...

Страница 13: ...ettings to the DCM hardware s flash memory and the DCM hardware can be disconnected from the host PC NOTE QSC updates these files regularly as new models are introduced from loudspeaker manufacturers...

Страница 14: ...operating voltage information printed on it Locate the sticker note the rated voltage and ensure the AC circuit you intend to use is properly rated Locate the IEC style AC power cord supplied with yo...

Страница 15: ...Ch 1 and Subcode 1 4 I MON Ch 1 and Subcode 2 5 Clip Protect Ch 1 6 Hard Ground 7 Ch 1 Plus Signal 8 Ch 2 Plus Signal 9 15V from Amplifier 10 Data Reference Ground 11 Ch 2 Minus Signal 12 Amplifier I...

Страница 16: ...Description 1 not used 2 not used 3 Back Surround Left 4 not used 5 not used 6 Back Surround Right 7 Ground Digital Inputs 8 not used 9 Right Extra 10 Surround Left 11 Surround Right 12 not used 13 no...

Страница 17: ...T 22 AES4 Bsl Bsr OUT 23 AES2 C SW OUT 24 AES2 C SW OUT 25 Chassis Ground Hearing Impaired The Hearing Impaired output signal is available on the screw terminal connector on the rear of the DCM The ou...

Страница 18: ...oise pick up than unbalanced connections External Speaker Connection The monitor signal is available on the screw terminals at the rear of the DCM This pow ered signal can be connected directly to an...

Страница 19: ...to the sound while in the Bypass position While in the bypassed position adjust the potentiometers to most closely match the normal position sound 3 Monitoring audio mix adjustments The DCM Manager s...

Страница 20: ...audible but all attempts to get it louder fail connect the DCM to a PC running DCM Manager software and check the Monitor Attenuation Levels settings on the Monitor Setting page These settings have a...

Страница 21: ...f switching the BYPASS to EMERGENCY does not restore sound to the center channel Verify the DCM is receiving input signals from the Cinema Processor Verify connections from the Cinema Processor to the...

Страница 22: ...0 01 Analog in 0 008 Digital in 20 Hz to 20 kHz all filters flat Frequency Response 20 Hz to 20 kHz D to A Conversion 24 bit delta sigma 128x oversampled Filter Topology 24 bit digital IIR Crossover...

Страница 23: ...Dimensions 19 wide x 5 25 high x 15 deep Weight 16 5 lbs 7 2 kg Line Voltage 100 VAC 240 VAC 50 60 Hz Safety Agency Approvals UL 60950 1 CSA RoHS WEE IEC 60950 1 EMC Approvals FCC Class B Connectors...

Страница 24: ...ions via pre paid transportation with a copy of proof of purchase i e sales receipt This warranty provides that the examination of the return product must indicate in our judgment a manufacturing defe...

Отзывы: