background image

Software Description

DCM Manager Windows Software

To access the functions of the DCM hardware, you must use QSC’s DCM Manager 2007 control software. A USB cable is used to connect 
your PC to the DCM. One of the computer’s available USB ports provides communications between the DCM Manager software and the 
DCM hardware. The PC must meet the minimum System Requirements as outlined in the Introduction section of this manual. The USB 
cable should be no longer than 5 meters. For longer distances, USB hubs, USB line extenders, or active USB extension cables must be 
used.

A typical cinema installation should require this setup procedure ONLY during the initial installation of the system. One particular advan-
tage of the DCM Manager software and DCM hardware is the ability to calibrate one DCM-based cinema system and easily download 
ALL of these settings to any number of additional DCM units in venues that are similarly equipped.

To aid in calibrating the crossover settings, the DCM Manager control software includes a database including many well known cinema 
loudspeakers. This data will automatically set the DSP filters and transducer alignment delay settings within the DCM hardware accord-
ing to the settings recommended by the loudspeaker manufacturer for optimum sound performance. Select loudspeakers for each of the 
physical locations (L,C,R, SL, SR, SUB), and a large portion of the system calibration is finished!

After loudspeakers have been selected in the DCM Manager software, processing parameters can be adjusted real-time. When settings 
are complete, the software can save the settings to the DCM hardware’s flash memory and the DCM hardware can be disconnected from 
the host PC.

NOTE: QSC updates these files regularly as new models are introduced from loudspeaker manufacturers or settings are improved. Visit our 
website http//:www.qscaudio.com for the latest cinema products information and technical support.

Software Installation

1- 

Start the PC.

2-

 Exit any programs that may be running.

3- 

Insert the QSC DCM Manager 2007 CD in the CD-ROM drive and close the drive.

4-

 The installation routine will automatically start. Follow the instructions on screen.

5- 

If the install does not automatically start, select Run from the Windows Start menu, specify the appropriate drive and select setup.exe; 

the installation routine will start.

6- 

Windows VISTA only- If a message indicating the program did not install correctly is displayed, select “Reinstall Using Recommended 

Settings”.

Starting the Program

1- 

Connect the USB cable between the host PC and the DCM hardware. When connecting for the first time, the Found New Harware wiz-

ard will be displayed.
     Windows XP:
     On the first screen, select “No, not at this time” and click “Next”. On the next screen, the default selection “Allow Windows  
     to select a driver” will be highlighted; click “Next”. If a warning stating the driver is not signed appears, you may safety select
     “Continue.” The driver will then be installed.
     Windows Vista:
     On the “Found New Hardware” window, select ‘Locate and install driver software (recommended).’
     If a Windows Security message appears, Select ‘Install this driver anyway.’ The driver will then be installed.
 

2-

 The DCM Manager program can be launched using the Windows Start/Programs selection.

Using the DCM Manager Software

After launching the DCM Manager program, click on the Help menu item for a full-featured software help system.

Содержание DCM 10

Страница 1: ...DCM Series Digital Cinema Monitor Crossover System User Manual DCM 10 DCM 10D DCM 30 DCM 30D TD 000265 00 TD 000265 00 A...

Страница 2: ...or moisture does not operate normally or has been dropped 15 When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions may be created by an uneven weight distri...

Страница 3: ...circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or TV technician for help THIS PRODUCT IS INTENDED FOR CONNECTION TO A TN OR IT POWER SYSTEM S...

Страница 4: ...ng Control In addition to the monitoring of your amplifier s audio I O your DCM includes QSC s exclusive Load Fault detection feature The DCM monitors for possible loudspeaker system or wiring faults...

Страница 5: ...he signal from analog to digital and back again which is designed to minimize all background noise and react to the dynamic range of any film track 4 Loudspeaker Database pre programmed settings QSC h...

Страница 6: ...Monitor Loudspeaker On the rear panel are a set of screw terminals marked EXTERNAL SPKR These are for connection to an external monitor loudspeaker As shipped from the factory a jumper between the IN...

Страница 7: ...4 Subwoofer output 5 Alternate equalization select input 6 Auxiliary audio input 7 Hearing impaired output 8 Emergency bypass level controls and switch 9 Main analog input from cinema processor 10 Ana...

Страница 8: ...ermines the function of the Monitoring Select but tons to the right of the AMPS PROC button The LEDs directly over the AMPS PROC button indicate what selected function the Monitor Select buttons will...

Страница 9: ...t on all amplifier outputs To sense real world conditions these measurements must be found to be out of range several times before the Load Fault condition is indicated on the front panel If you are s...

Страница 10: ...io power INPUT SELECT Switch Use this switch to select the input source of the DCM In the ANALOG position input is from the MAIN ANALOG INPUT and the SURROUND EX INPUT if this option is installed If t...

Страница 11: ...nal to the EXTERNAL SPKR terminal SUB OUT provides the identical audio as the subwoofer DataPort This connection cannot be monitored or include any of the Fault Analysis functions because there are no...

Страница 12: ...chassis and rack can be damaged if the DCM is not properly supported Unless the DCM is being installed in its final fixed location QSC strongly recommends supporting the rear of the unit Rear rack ear...

Страница 13: ...ettings to the DCM hardware s flash memory and the DCM hardware can be disconnected from the host PC NOTE QSC updates these files regularly as new models are introduced from loudspeaker manufacturers...

Страница 14: ...operating voltage information printed on it Locate the sticker note the rated voltage and ensure the AC circuit you intend to use is properly rated Locate the IEC style AC power cord supplied with yo...

Страница 15: ...Ch 1 and Subcode 1 4 I MON Ch 1 and Subcode 2 5 Clip Protect Ch 1 6 Hard Ground 7 Ch 1 Plus Signal 8 Ch 2 Plus Signal 9 15V from Amplifier 10 Data Reference Ground 11 Ch 2 Minus Signal 12 Amplifier I...

Страница 16: ...Description 1 not used 2 not used 3 Back Surround Left 4 not used 5 not used 6 Back Surround Right 7 Ground Digital Inputs 8 not used 9 Right Extra 10 Surround Left 11 Surround Right 12 not used 13 no...

Страница 17: ...T 22 AES4 Bsl Bsr OUT 23 AES2 C SW OUT 24 AES2 C SW OUT 25 Chassis Ground Hearing Impaired The Hearing Impaired output signal is available on the screw terminal connector on the rear of the DCM The ou...

Страница 18: ...oise pick up than unbalanced connections External Speaker Connection The monitor signal is available on the screw terminals at the rear of the DCM This pow ered signal can be connected directly to an...

Страница 19: ...to the sound while in the Bypass position While in the bypassed position adjust the potentiometers to most closely match the normal position sound 3 Monitoring audio mix adjustments The DCM Manager s...

Страница 20: ...audible but all attempts to get it louder fail connect the DCM to a PC running DCM Manager software and check the Monitor Attenuation Levels settings on the Monitor Setting page These settings have a...

Страница 21: ...f switching the BYPASS to EMERGENCY does not restore sound to the center channel Verify the DCM is receiving input signals from the Cinema Processor Verify connections from the Cinema Processor to the...

Страница 22: ...0 01 Analog in 0 008 Digital in 20 Hz to 20 kHz all filters flat Frequency Response 20 Hz to 20 kHz D to A Conversion 24 bit delta sigma 128x oversampled Filter Topology 24 bit digital IIR Crossover...

Страница 23: ...Dimensions 19 wide x 5 25 high x 15 deep Weight 16 5 lbs 7 2 kg Line Voltage 100 VAC 240 VAC 50 60 Hz Safety Agency Approvals UL 60950 1 CSA RoHS WEE IEC 60950 1 EMC Approvals FCC Class B Connectors...

Страница 24: ...ions via pre paid transportation with a copy of proof of purchase i e sales receipt This warranty provides that the examination of the return product must indicate in our judgment a manufacturing defe...