QSC CMS-5000 Скачать руководство пользователя страница 25

18

 TD-001576-01-A

Rebooting the CMS

You can force the CMS to reboot using one of the following methods:
1.  Reset the CMS from the UI by navigating to the System->Server page and clicking on the Reboot Server button on the Server Tools 

panel. If using with Q-SYS, the CMS can be reset from Configurator.

2.  Using a pin or tip of a paper clip, press the reset button located inside the small hole to the left of the USB ports on the front panel 

until all the front panel LEDs turn on indicating the CMS is rebooting.

3.  Power cycle the projector.  Follow projector manufacturer safety guidelines when restarting the projector to protect the bulb from 

being "hot cycled".

LED Modes

The chart below describes the various modes of the CMS as indicated by the front panel status LEDs.

— Table 8 — 

TAMPER

FLT

PWR

RDY

RED

YEL

GRN

GRN

CMS-5000 Mode
Unpowered

OFF

OFF

OFF

OFF

Initialization

ON

ON

ON

ON

Power On Self-test

OFF

FLASH

ON

FLASH

Awaiting Projector Marriage

OFF

OFF

ON

FLASH

Normal Operation

OFF

OFF

ON

ON

Service Door Open

FLASH

OFF

ON

OFF

Recoverable Error

OFF

ON

ON

OFF

Tampered (Return to factory)

ON

OFF

ON

OFF

NOTE: 

NOTE:

If the PWR LED is the only one turned on, the CMS is unable to boot from the main firmware image. Follow the directions 

in the section below to force the CMS to boot to the default factory firmware image. The CMS will then be fully operational and 

will allow you to re-install and repair the main firmware image.

NOTE: 

NOTE:

If a Recoverable Error is indicated, power cycle the CMS-5000 to return to an operational state. If a reboot does not 

return the CMS to an operational state, contact Technical Services.

Force Boot to Factory Image

A factory default version of the CMS firmware is stored on the CMS-5000.  This version will allow you to use the CMS, but is primarily 
recommended for re-installing the main firmware in cases of error.  You can force the CMS to boot up to the factory default firmware 
version that was installed when the CMS was manufactured as follows:
1.  Power off the CMS (you will need to power off the projector)
2.  Using a pin or tip of a paper clip, press and keep pressed the restore button located inside the small hole to the left of the Sync inputs on 

the front panel (button is not marked)

3.  Power up the projector and CMS as you continue pressing the Restore button.
4.  In approximately 15 seconds, LEDs above the HS ETH port will flash green (left flash, right flash, left flash). This indicates the CMS is 

booting from the factory default image and you may release the Restore button 

If you perform a software update while running the factory default image, the update will not affect the factory default; it will update the main 
firmware image. After a software update, the CMS will resume booting into main firmware.
If you need to return to the main firmware without running an update, perform the following procedure:
1.  Power off the CMS (you will need to power off the projector)
2.  Using a pin or tip of a paper clip, press and keep pressed the restore button located to the left of the Sync inputs on the front panel 

(button is not marked)

3.  Power up the projector and CMS as you continue pressing the Restore button.

Содержание CMS-5000

Страница 1: ...TD 001576 01 A TD 001576 01 Cinema Media Server User Manual Cinema Media Server CMS 5000...

Страница 2: ...for safe operation of the equipment is not compromised 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Do no...

Страница 3: ...y while in use and when removed from service The end user of the CMS 5000 is classified by FIPS as a Cryptographic Officer and is responsible for placing and maintaining the projector system into a FI...

Страница 4: ...364 O GB T 26572 O Indicates that the concentration of the substance in all homogeneous materials of the part is below the relevant threshold specified in GB T 26572 X GB T 26572 X Indicates that the...

Страница 5: ...ration iv Package Contents 1 Introduction 1 Front Panel Features 1 Installation 2 Required Tools 2 Installing the CMS 5000 into a Projector 3 Power up 4 Projector Marriage with CMS 5000 4 Barco 4 NEC...

Страница 6: ...ings 10 Video Alignment Delay 10 Q LAN Audio Output Enable 10 AES Channel Assignments 10 Q SYS Channel Assignments 11 DTS X Settings 11 DTS X VBAP Generator 11 Automation Settings 12 Activating and Cr...

Страница 7: ...ckup and Restore 17 Restoring Factory Default Configurations 17 Check Connections 17 Connect via Projector to Check Settings 17 Rebooting the CMS 18 LED Modes 18 Force Boot to Factory Image 18 Reseat...

Страница 8: ...ting hole options in order to emphasize the connectors section NOTE At power up the POWER LED is on and the READY LED is off During CMS initialization all the LEDs except POWER will blink Once the REA...

Страница 9: ...s the CMS is ready to perform its functions 13 USB 3 0 Both connectors support USB 3 0 and can be used for ingest 14 ACT LED Yellow indicates link on HS ETH alternating yellow green indicates activity...

Страница 10: ...is not hot pluggable so be sure power to the projector is turned off 5 With ESD protection in place remove the CMS 5000 from its anti static bag and slide it into the IMB slot on the projector Make su...

Страница 11: ...tions 13 If the CMS 5000 is being used with a Q SYS core install the Q LAN network cables into the LAN A and LAN B ports LAN B connection only required when using network redundancy Power up The CMS 5...

Страница 12: ...ing CMS UI Through Q SYS Designer The UI can be accessed via Q SYS Configurator Select the CMS in the Configurator list and click on OPEN WEB UI Browser Security Warnings In some instances accessing t...

Страница 13: ...ds to prevent unauthorized access CAUTION If the default logins have been changed and you no longer have the required user names and passwords to log in at manager or projectionist level contact your...

Страница 14: ...are update The update will take several minutes The CMS will reboot automatically once the update is complete To maximize the efficiency of the update avoid ingesting or playing content during the upd...

Страница 15: ...ps 192 168 1 200 43756 Network Configuration Recommendations The CMS 5000 uses ethernet networking to provide key features Control of the CMS 5000 access to other devices used in playback for automati...

Страница 16: ...use 10G modules The CMS will not operate with 1G SFP fiber modules Fiber optic cabling Assuming SR Modules as described above use LC LC Duplex OM3 50 125 Multimode Fiber Cable Copper modules 10GBASE T...

Страница 17: ...signments The default channel assignments for AES output channels 1 16 are based on the standard as called out by ISDCF Doc4 16 Channel Audio Packaging Guide as shown below Any channel can be reassign...

Страница 18: ...de conform to the VBAP file configuration requirements If the VBAP file is invalid rendered audio may not play correctly or at all You may also export the file for use in another system DTS X VBAP Gen...

Страница 19: ...RightRearSurroundHeight RRSH RRSHnoURIByDTS CenterSurround CS urn smpte ul 060E2B34 0401010D 0302010D 00000000 LeftCenterHeight LCH http dts com mda channels LCH RightCenterHeight RCH http dts com mda...

Страница 20: ...where is the ascii value of the character in hexadecimal notation Some commonly used values for reference x0A Line Feed x0D Carriage Return x09 Tab character Cue Bundles Cue bundles can be created to...

Страница 21: ...connections may not support discovery Access to the CMS 5000 is password controlled using the same credentials as the CMS Web UI You will need to login with an Installer or Administrator account Once...

Страница 22: ...ontent page when the Internal storage source is selected Viewing Available Content Content ingest and management is performed on the Content page available to log in levels of manager and above On thi...

Страница 23: ...show any warnings about the schedule If there are no warnings associated with the schedule the status will instead show warnings associated with the scheduled playlist missing KDMs missing Content etc...

Страница 24: ...ings from the previous server This can also facillitate returning the CMS to a known good state after changes have resulted in problematic performance Restoring Factory Default Configurations Use the...

Страница 25: ...cycle the CMS 5000 to return to an operational state If a reboot does not return the CMS to an operational state contact Technical Services Force Boot to Factory Image A factory default version of the...

Страница 26: ...tached to the CMS 5000 6 Unscrew the two cage screws at the edges of the faceplate if included NEC and Barco models 7 Pull directly out on the CMS 5000 faceplate to remove the card from the slot 8 Ins...

Страница 27: ...onditions between 5 and 95 non condensing Service Life 10 Years Country of Origin U S A Front Panel Controls and Indicators Status Indicators LED Power Ready Fault Tamper Drive Status Ingest Network s...

Страница 28: ...ervices Tel 1 800 772 2834 U S only Tel 1 714 957 7150 FAX 1 714 754 6173 QSC Self Help Portal Access our Self Help Portal for additional information FAQs and documents You may also register or login...