EXPLANATION OF SYMBOLS

The term 

“WARNING!” 

indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily 

injury or death.
The term 

“CAUTION!”

 indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, 

it may result in damage to the equipment that may not be covered under the warranty.
The term 

“IMPORTANT!”

 indicates instructions or information that are vital to the successful completion of the procedure.

The term 

“NOTE”

 is used to indicate additional useful information.

The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated 

«dangerous» voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock 
to humans.

The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and 

operating and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

WARNING! 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR 

MOISTURE. 

Elevated Operating Ambient Temperature – If installed in a closed or multi-unit rack assembly, the ambient operating 

temperature of the rack environment may be greater than room ambient. Consideration should be given to ensure that the 

maximum operating temperature range -10°C to 50°C (14°F to 122°F ) is not exceeded. Reduced Air Flow – Installation 

of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not 

compromised.

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with a dry cloth.
7.  Do not block any ventilation opening. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
9.  To reduce the risk of electrical shock, the power cord shall be connected to a mains socket outlet with a protective earthing 

connection.

10.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the 

other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your 
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

11.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they 

exit from the apparatus.

12.  Only use attachments/accessories specified by the manufacturer.
13.  Unplug this apparatus during lightning storms or when unused for long periods of time.
14.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 

power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been dropped.

15.  The appliance coupler, or the AC Mains plug, is the AC mains disconnect device and shall remain readily operable after installation.
16.  Adhere to all applicable, local codes.
17.  Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation.
18.  Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. Clean only with a dry cloth.
19.  Do not unplug the unit by pulling on the cord, use the plug.
20.  Do not submerge the apparatus in water or liquids.
21.  Keep ventilation opening free of dust or other matter.

Содержание Axon DTH1620

Страница 1: ...TD 001622 01 A TD 001622 01 Axon DTH1620 Themed Attraction Amplifier User Manual Model DTH1620 Model DTH1620...

Страница 2: ...th a dry cloth 7 Do not block any ventilation opening Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other...

Страница 3: ...to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception w...

Страница 4: ...able for safe use in areas below 2000m above sea level Only suitable for safe use in non tropical climates Warranty For a copy of the QSC Limited Warranty visit the QSC website at www qsc com What s i...

Страница 5: ...ut J1 8 Headphone Interface J2 8 Input Power Interface J3 8 Network Interface J4 9 Audio Output J5 9 Connector Cabling 9 Connectors J1 and J5 9 Connector J2 9 Connector J3 9 Connector J4 9 Amplifier T...

Страница 6: ...olume 15 Get Set Output Master Volume 15 Status 16 Get Metering Data 16 Get Channel Name 17 Get Device Lock 17 Get Set Fan 17 Specifications 18 Contact QSC 19 QSC LLC 19 Sales Marketing 19 QSC Custome...

Страница 7: ...are not included Figure 1 Connector Panel 9 10 11 12 13 14 15 16 6 5 4 3 2 1 1 2 3 4 5 6 7 8 N9 N10 N11 N12 N13 N14 N15 N16 N1 N2 N3 N4 N5 N6 N7 N8 Connectors J1 J5 Audio Output J5 1 8 Positive analog...

Страница 8: ...4 15 16 9 10 11 12 13 14 15 16 Headphone Interface J2 Refer to Get Set Headphone Limit on page 14 Pin Description 1 Headphone R 2 Volume Ground Reference Potentiometer Low 3 Volume Reference Voltage P...

Страница 9: ...requirements listed here would allow the unit to function in most applications Connectors J1 and J5 Loudspeaker P wire 18 AWG Copper stranded you may want different color for each channel output Louds...

Страница 10: ...d Amplifier Bottom View Refer to Figure 3 The serial number information for the unit is found on a label on the bottom side of the amplifier Figure 2 FAN FAULT DANTE OK AMPS OK POWER OK FACTORY RESET...

Страница 11: ...01622 01 A Installation Dimensions Figure 4 145 03 mm 5 710 in 215 90 mm 8 50 in 228 6 mm 9 0 in 176 53 mm 6 95 in 172 72 mm 6 80 in 169 16 mm 6 660 in 51 46 mm 2 02 in 45 97 mm 1 809 in 4x 0 177 in 4...

Страница 12: ...for the mounting surface material to secure the amplifier in the selected location 4 Connect and secure the cables to allow for appropriate stress relief Selecting a Power Supply for Your Installation...

Страница 13: ...Gain 103 to 24 Get Output Master Volume GOMV Set Output Master Volume SOMV Gain 103 to 24 Get Unit Status GSTAT Get Metering Data GSM Get Channel Name GCN Channel ID 1 to 16 Get Device Lock GDEVICELO...

Страница 14: ...dB Master and Channel volumes are set to 0 dB Master and Output mutes are disabled unmuted All subscribed Dante streams are unsubscribed no streams selected If a static IP had been selected it is rese...

Страница 15: ...of commands gets and sets the volumes for each output channel parameter 1 is 1 16 or for all output channels parameter 1 is 0 range is 24 dB to 103 dB The total output volume is a combination of the...

Страница 16: ...all channel data The entire structure is 38 bytes Get Metering Data This command gets all metering data for all Dante channels The response contains 64 hexadecimal formatted values Values 1 through 1...

Страница 17: ...ample Response Get Device Lock GDEVICELOCK CR ACK GDEVICELOCK UNLOCKED CR Table 20 Get Device Lock Syntax Example Get Set Fan These commands get the Fan Enable status or sets the Fan Enable If the Fan...

Страница 18: ...hannel driven THD N 1W into 16 ohms 1KHz 0 1 THD N one channel driven THD N 10W into 16 ohms 1KHz 0 1 THD N one channel driven Maximum Digital Input Level 0dBFS Cooling Fan With Thermal Speed Control...

Страница 19: ...5 PM PST Excludes Holidays Voice 1 714 957 7150 1 800 772 2834 toll free U S only FAX 1 714 754 6173 QSC Self Help Portal Access our Self Help Portal for additional information FAQs and documents You...