Specifications

Specification Description

Test Result

Additional Info

Frequency Response (8 ohm) 1W

+0.5dB, -1.5dB

Frequency Response (8 ohm) 20W

+0.5dB, -1.5dB

Frequency Response (16 ohm) 1W

+1.0dB, -0.5dB

Frequency Response (16 ohm) 10W

+1.0dB, -0.5dB

Noise (20Hz - 20KHz) into 8Ω

-73dBu

Noise (20Hz - 20KHz) into 16Ω

-72dBu

Signal to Noise (20Hz - 20KHz) 20W 8Ω

97dB

Signal to Noise (20Hz - 20KHz) 1W 8Ω

84dB

DBFS for 1W into 8 ohms

-18.500dBFS

DBFS for 20W into 8 ohms

-5.500dBFS

DBFS for 1W into 16 ohms

-15.700dBFS

DBFS for 10W into 16 ohms

-5.600dBFS

Output Circuitry

Class D

THD+N @ 1W into 8 ohms @ 1KHz

<0.1%

THD+N, one channel driven

THD+N @ 20W into 8 ohms @ 1KHz

<0.2%

THD+N, one channel driven

THD+N @ 1W into 16 ohms @ 1KHz

<0.1%

THD+N, one channel driven

THD+N @ 10W into 16 ohms @ 1KHz

<0.1%

THD+N, one channel driven

Maximum Digital Input Level

0dBFS

Cooling

Fan With Thermal Speed Control

Input Connectors

+24VDC

Molex 6-pin

Output Connectors

Speaker

Molex 16-pin

Headphone/Volume Control

Molex 6-pin

Ethernet Connector

RJ-45 With Link and Activity LED indicators

Top Panel Indicators

Power OK, Amps OK, Dante OK Fan Fault

Operating Mode

Low Impedance 8 ohm/16 ohm only

Amplifier Control (Network)

Control and Status Via the Network, see manual for API details

Amplifier Volume Control (Remote)

10K Linear Potentiometer

Dimensions

9” (229mm) D x 6.66” (169) W x 2.02” (51mm) H

Net Weight

2.4 lbs. (1.1kg)

Shipping Weight

2.842 lbs (1.29 kg)

Power Requirements

+24VDC @ 3A, all channels 1/8 power   

+24VDC @ 17.5A, all channels full power

Carton Contents

DTH1620 Amplifier

Содержание Axon DTH1620

Страница 1: ...TD 001622 01 A TD 001622 01 Axon DTH1620 Themed Attraction Amplifier User Manual Model DTH1620 Model DTH1620...

Страница 2: ...th a dry cloth 7 Do not block any ventilation opening Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other...

Страница 3: ...to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception w...

Страница 4: ...able for safe use in areas below 2000m above sea level Only suitable for safe use in non tropical climates Warranty For a copy of the QSC Limited Warranty visit the QSC website at www qsc com What s i...

Страница 5: ...ut J1 8 Headphone Interface J2 8 Input Power Interface J3 8 Network Interface J4 9 Audio Output J5 9 Connector Cabling 9 Connectors J1 and J5 9 Connector J2 9 Connector J3 9 Connector J4 9 Amplifier T...

Страница 6: ...olume 15 Get Set Output Master Volume 15 Status 16 Get Metering Data 16 Get Channel Name 17 Get Device Lock 17 Get Set Fan 17 Specifications 18 Contact QSC 19 QSC LLC 19 Sales Marketing 19 QSC Custome...

Страница 7: ...are not included Figure 1 Connector Panel 9 10 11 12 13 14 15 16 6 5 4 3 2 1 1 2 3 4 5 6 7 8 N9 N10 N11 N12 N13 N14 N15 N16 N1 N2 N3 N4 N5 N6 N7 N8 Connectors J1 J5 Audio Output J5 1 8 Positive analog...

Страница 8: ...4 15 16 9 10 11 12 13 14 15 16 Headphone Interface J2 Refer to Get Set Headphone Limit on page 14 Pin Description 1 Headphone R 2 Volume Ground Reference Potentiometer Low 3 Volume Reference Voltage P...

Страница 9: ...requirements listed here would allow the unit to function in most applications Connectors J1 and J5 Loudspeaker P wire 18 AWG Copper stranded you may want different color for each channel output Louds...

Страница 10: ...d Amplifier Bottom View Refer to Figure 3 The serial number information for the unit is found on a label on the bottom side of the amplifier Figure 2 FAN FAULT DANTE OK AMPS OK POWER OK FACTORY RESET...

Страница 11: ...01622 01 A Installation Dimensions Figure 4 145 03 mm 5 710 in 215 90 mm 8 50 in 228 6 mm 9 0 in 176 53 mm 6 95 in 172 72 mm 6 80 in 169 16 mm 6 660 in 51 46 mm 2 02 in 45 97 mm 1 809 in 4x 0 177 in 4...

Страница 12: ...for the mounting surface material to secure the amplifier in the selected location 4 Connect and secure the cables to allow for appropriate stress relief Selecting a Power Supply for Your Installation...

Страница 13: ...Gain 103 to 24 Get Output Master Volume GOMV Set Output Master Volume SOMV Gain 103 to 24 Get Unit Status GSTAT Get Metering Data GSM Get Channel Name GCN Channel ID 1 to 16 Get Device Lock GDEVICELO...

Страница 14: ...dB Master and Channel volumes are set to 0 dB Master and Output mutes are disabled unmuted All subscribed Dante streams are unsubscribed no streams selected If a static IP had been selected it is rese...

Страница 15: ...of commands gets and sets the volumes for each output channel parameter 1 is 1 16 or for all output channels parameter 1 is 0 range is 24 dB to 103 dB The total output volume is a combination of the...

Страница 16: ...all channel data The entire structure is 38 bytes Get Metering Data This command gets all metering data for all Dante channels The response contains 64 hexadecimal formatted values Values 1 through 1...

Страница 17: ...ample Response Get Device Lock GDEVICELOCK CR ACK GDEVICELOCK UNLOCKED CR Table 20 Get Device Lock Syntax Example Get Set Fan These commands get the Fan Enable status or sets the Fan Enable If the Fan...

Страница 18: ...hannel driven THD N 1W into 16 ohms 1KHz 0 1 THD N one channel driven THD N 10W into 16 ohms 1KHz 0 1 THD N one channel driven Maximum Digital Input Level 0dBFS Cooling Fan With Thermal Speed Control...

Страница 19: ...5 PM PST Excludes Holidays Voice 1 714 957 7150 1 800 772 2834 toll free U S only FAX 1 714 754 6173 QSC Self Help Portal Access our Self Help Portal for additional information FAQs and documents You...

Отзывы: