17
TD-001622-01-A
Get Channel Name
This command gets the name of the Dante channel corresponding to a channel.
Valid values are 1–16.
Description of Command
Example Command
Example Response
Get Channel Name
GCN 3<CR>
ACK GCN 3 Lobby<CR>
— Table 19 — Get Channel Name Syntax Example
Get Device Lock
This command returns the status of the Dante Device lock.
Description of Command
Example Command
Example Response
Get Device Lock
GDEVICELOCK<CR>
ACK GDEVICELOCK UNLOCKED<CR>
— Table 20 — Get Device Lock Syntax Example
Get/Set Fan
These commands get the Fan Enable status or sets the Fan Enable. If the Fan Enable is active and the Fan does not function then the
Fan LED will turn on RED. If the Fan is disabled and the internal temperature reaches 85 Degrees Celsius, the Fan LED will turn RED.
Description of Command
Example Command
Example Response
Description of Response
Get Fan setting
GFAN<CR>
ACK GFAN ON<CR>
Set Fan setting.
SFAN 1<CR>
ACK SFAN 1<CR>
— Table 21 — Get/Set Fan Enable Syntax Example