15
TD-001622-01-A
Get/Set Output Mute
This set of commands gets and sets the output mute status for each output channel (parameter 1 is 1...16) or for all output channels
(parameter 1 is 0).
Description of Command
Example Command
Example Response
Description of Response
Get mute setting for output channel 14
GOM 14<CR>
ACK GOM 14 ON<CR>
Unmute output channel 14
SOM 14 0<CR>
ACK SOM 14 0<CR>
Get mute settings for all output channels
GOM 0<CR>
ACK GOM 0 0xFFFF<CR>
Unmute output channels 1..4, mute output channels 5..16
SOM 0 0xFFF0<CR> ACK SOM 0 0xFFF0<CR>
— Table 13 — Get/Set Output Mute Syntax Example
Get/Set Output Master Mute
This set of commands gets and sets the output master mute status. The master mute mutes all channels simultaneously. Clearing
Master Mute will only clear the master mute state; it will not clear an individual channel’s mute state.
Description of Command
Example Command
Example Response
Description of Response
Get Master Mute setting
GOMM<CR>
ACK GOMM ON<CR>
Set Master Mute
SOMM 0<CR>
ACK SOMM 0<CR>
— Table 14 — Get/Set Output Master Mute Syntax Example
Get/Set Output Volume
This set of commands gets and sets the volumes for each output channel (parameter 1 is 1...16) or for all output channels (parameter 1
is 0) range is +24 dB to -103 dB. The total output volume is a combination of the individual channel and Master volume up to the 20W
maximum for the channel.
Description of Command
Example Command
Example Response
Description of Response
Get volume setting for output channel 9
GOV 9<CR>
ACK GOV 9 -30<CR>
Set volume setting for output channel 9
SOV 9 0<CR>
ACK SOV 9 0<CR>
Get volume settings for all output channels GOV 0<CR>
ACK GOV 0 -2 -3 0 … -1<CR>
2
2. 16 values space delimited following the 1nd param.
— Table 15 — Get/Set Output Volume Syntax Example
Get/Set Output Master Volume
This set of commands gets and sets the Output Master Volume. Range is +24 dB to -103 dB. The Master volume is applied after the
individual channel volume settings. For a direct pass through of channel volumes, the Master Volume should be set to 0 db. The total
output volume is a combination of the individual channel and Master volume up to the 20 W maximum for the channel.
Description of Command
Example Command
Example Response
Description of Response
Get Master Volume setting
GOMV<CR>
ACK GOMV -3<CR>
Set Master volume setting.
SOMV 9 0<CR>
ACK SOMV -3<CR>
— Table 16 — Get/Set Master Output Volume Syntax Example