INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNwHa Q CeLLS GMBH – Na

INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNwHa Q CeLLS GMBH – Na

Fig. 1: 

 External dimensions in inch (mm) and components for Q.PRO-G3, Q.PRO BFR-G3, Q.PEAK-G3, Q.PEAK BLK-G3, Q.PLUS-G3

Installation Site

Please note the following guidelines that apply to the installation 
site:

• 

The modules have been tested according to UL 1703 and IEC 
61215 for operation in a temperate climate.

• 

Solar modules are not explosion-proof.

 

Ä

Do  not  operate  solar  modules  near  highly  flammable  gas  and 

vapors (e.g. gas tanks, gas stations).

 

Ä

Do not install modules in enclosed space.

 

Ä

Do not install modules in locations where they may be submerged 
in water for lengthy periods.

 

Ä

Do  not  use  modules  as  a  substitute  for  the  normal  roofing 

 

(e.g. modules are not rainproof).

Prevention of Shadowing effects

Optimal solar irradiation leads to maximum energy output:

 

Ä

For this reason, install the modules so that they face the sun. 

 

Ä

Avoid shadowing  (due to objects such as buildings, chimneys or 
trees). 

 

Ä

Avoid partial shading (for example through overhead lines, dirt, 
snow).

Limitations

The solar modules are designed for the following applications:

• 

Operating temperatures from –40 °F to +185 °F. 

• 

Wind and snow loads up to max. 5,400 Pa (as tested according 
to IEC 61215).

• 

Installation using a mounting frame for solar modules.

Mounting Frame requirements

Requirements for the mounting frame:

• 

Conforms to the necessary structural requirements.

• 

Compliant with local snow and wind loads.

• 

Properly fastened to the ground, the roof, or the façade.

• 

Forces acting on the module are relayed to the mounting substructure.

• 

Ensures sufficient rear ventilation of the module.

• 

Guarantees long-term stability. 

• 

Has electrochemical series that prevent corrosion among different 
metals.

• 

Allows for stress-free expansion and contraction due to temperature 

fluctuations.

 

Ä

Ensure that no mechanical stresses (e.g., caused by vibrations, 
twisting, or expansion) are generated on the module. 

 

Ä

Ensure that the clamps and the mounting frame are compatible.  

Clamp System requirements

Use customary clamps that satisfy the following requirements:

• 

Clamp width: 

 1.50 in  (38  mm).

• 

Clamp height compliant with a 1.38 in (35 mm) frame height.

• 

Clamp depth: 0.20–0.47 in (5–12 mm).

• 

Clamps are not in contact with the front glass.

• 

Clamps do not deform the frame.

• 

Clamps that satisfy the structural requirements of the installation site. 
 

• 

Long-term stable clamps that securely affix the module to the 

mounting frame.

Module orientation requirements

• 

Vertical or horizontal installation is permitted.

• 

Installation with a junction box at the bottom is permitted for 

modules with junction boxes classified as IP67.

 

Ä

Ensure that rain and melting snow can run off freely. No water 
accumulation.

 

Ä

Ensure that the drainage holes in the frame are not covered. No 
sealing.

• 

A module with 45.67 in long (1,160 mm) cable 
can be wired as a "2nd next neighbor".

 

"2nd next neighbor" - Wiring without a return 
cable.

‚

 Standard wiring with a return cable

Inverter

Inverter

1

2

 

Ä

Maintain the permissible angle of inclination.

• 

Minimum angle of inclination: 3°

• 

Maximum angle of inclination: 80°

• 

> 20°: self-cleaning effect.

2.1  Technical specifications

2 PLaNNING

2.2  requirements

2 PLaNNING

Product label

≥ 

45.67" (

≥ 

1160 mm)

 

 

  

38.6" (980 mm)

  

 

5.91" (150 mm)

  

37.76" (959 mm)

 

mounting slots and grounding holes

1.38" (35 mm)

6 × grounding holes

Ø 0.177" (4.5 mm)

65.7" (1670 mm) 

39.4" (1000 mm)

Junction bo×

4 × mounting slots

DETAIL A

8 × Drainage holes

Cable with

connectors

Frame

DETAIL A

0.630" (16 mm)

0.315" (8 mm)

0.799" (20.3 mm)

NA

NA

Содержание Q.Peak BLK-G3

Страница 1: ...Valid for North America Q Pro G3 Q Pro BFR G3 Q Peak G3 Q Peak BLK G3 Q PLUS G3 Installation and Operation Manual...

Страница 2: ...amage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Units Where both metric and U S units for example inches are shown me...

Страница 3: ...complete solar power system It may be necessary to carry out a structural analysis for the entire project If your questions are not satisfactorily answered in the manual please contact your system sup...

Страница 4: ...ufficient rear ventilation of the module Guarantees long term stability Has electrochemical series that prevent corrosion among different metals Allows for stress free expansion and contraction due to...

Страница 5: ...0 380 CL1 9 65 17 52 245 445 7 09 14 96 180 380 2 Planning 2 3 Mounting options Specifications Module type Mounting option Clamping range1 IN Mm Allowed static load2 PA TEST LOAD acc IEC 61215 PA Q PR...

Страница 6: ...termining the maximum number of modules in the string Parallel Connection Modules may be damaged by the occurrence of reverse currents caused by module defects ground leaks or defective insulation Ens...

Страница 7: ...ng until installation Store the modules securely in cool and dry rooms The packaging is not weatherproof Danger Risk of fatal injury due to electric shock Do not install damaged modules Inform your ve...

Страница 8: ...to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components Do not drill any other holes 3 2 Preparation of installation 3 Inst...

Страница 9: ...wiring with extreme caution Ensure that the modules are disconnected at the inverter prior to separation Be sure to observe the specified time intervals after switching off the inverter High voltage c...

Страница 10: ...ock Ensure that all electrical components are in a proper dry and safe condition A module with 47 24in long 1 210 mm cable can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return...

Страница 11: ...rformance Maintenance The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure and all electric...

Страница 12: ...vine Center Drive Suite 1250 Irvine CA 92618 USA TEL 1 848 748 59 96 FAX 1 949 748 59 84 EMAIL q cells usa q cells com WEB www q cells us Subject to change without notice Hanwha Q CELLS GmbH Installat...

Отзывы: