8
9
INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNwHa Q CeLLS GMBH – Na
INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNwHa Q CeLLS GMBH – Na
Fig. 2:
Installation options for crystalline Q CELLS modules. All dimensions are given in inch (mm). Also observe the allowed static
loads and clamping range as specified on the following page.
The illustrated installation options apply for both horizontal and vertical module orientation.
Module
Clamp
Subconstruction
Mounting profile
2.3 Mounting options
2 PLaNNING
TyPe oF
INSTaLLaTIoN
MoDULe
PoINT MoUNTING SySTeM
LINear MoUNTING SySTeM
INSTaLLaTIoN wITH
CLaMPS
Q.PRO-G3
Q.PRO BFR-G3
Q.PEAK-G3
Q.PEAK BLK-G3
Q.PLUS-G3
INSTaLLaTIoN
oN
MoUNTING
PoINTS
Q.PRO-G3
Q.PRO BFR-G3
Q.PEAK-G3
Q.PEAK BLK-G3
Q.PLUS-G3
4 x mounting
slots
4 x mounting
slots
FB1
13.58
(345)
11.02
280
13.58
(345)
11.02
280
FB2
4 x mounting
slots
4 x mounting
slots
INSTaLLaTIoN wITH
INSerTIoN ProFILeS
Q.PRO-G3
Q.PRO BFR-G3
Q.PEAK-G3
Q.PEAK BLK-G3
Q.PLUS-G3
not permitted
IP1
IP2
CL3
CL4
0 - 11.81
(0 - 300)
0 - 11.81
(0 - 300)
9.65 - 17.52
(245 - 445)
7.09 - 14.96
(180 - 380)
CL1
9.65 - 17.52
(245 - 445)
7.09 - 14.96
(180 - 380)
2 PLaNNING
2.3 Mounting options
Specifications
MoDULe TyPe
MoUNTING oPTIoN
CLaMPING raNGe
1
[IN (MM)]
aLLoweD STaTIC
LoaD
2
[Pa]
TeST LoaD
aCC. IeC 61215 [Pa]
Q.PRO-G3
Q.PRO BFR-G3
Q.PEAK-G3
Q.PEAK BLK-G3
Q.PLUS-G3
CL1
Push
9.65 - 13.58 (245 - 345)
13.62 - 17.51 (346 - 445)
3500
2400
5400
Pull
9.65 - 13.58 (245 - 345)
13.62 - 17.51 (346 - 445)
4000
3400
CL3
Push
9.65 - 17.51 (346 - 445)
4000
Pull
9.65 - 13.58 (245 - 345)
13.62 - 17.51 (346 - 445)
4000
3400
CL4
Push
0 - 11.81 (0 - 300)
1800
Pull
0 - 11.81 (0 - 300)
1600
FB1
Push
3500
Pull
3100
FB2
Push
4000
Pull
3100
IP1
Push
-
3700
Pull
-
3700
IP2
Push
-
1800
2400
Pull
-
1800
1
Distance between outer edge of module and middle of the clamp.
2
Describes the maximum module surface load (vertical to the module surface) regarding safety factors (e.g. EUROCODE). For this purpose,
the load value determined by load tests according to various criteria: laminate overlay, plastic deformation, module failure, and were
divided with a safety factor. The minimum calculated load value corresponds to the maximum permitted load.
CL1
9.65 - 17.52
(245 - 445)
7.09 - 14.96
(180 - 380)
CL3
CL4
0 - 11.81
(0 - 300)
0 - 11.81
(0 - 300)
9.65 - 17.52
(245 - 445)
7.09 - 14.96
(180 - 380)
13.58
(345)
11.02
280
FB2
4 x mounting
slots
4 x mounting
slots
4 x mounting
slots
4 x mounting
slots
FB1
13.58
(345)
11.02
280
IP1
IP2