2 PLANNING

2.3  Mounting options

Specifications

 

MODULE TYPE

MOUNTING OPTION

CLAMPING RANGE

1

TEST LOAD ACC. IEC 61215 PUSH/PULL [PA] 

Q.PRO L-G2

CL1 (4 point clamping on 

long side)

0 - 9.84 (0 - 250)

2400/2400

9.88 - 19.69 (251 - 500)

5400/4000

IP1 (Slide-in / long mo-

dule side)

5400/2400

IP2 (Slide-in / short 

module side)

2400/2400

FB1

5400/4000

1

 

Distance between outer edge of module and middle of the clamp.

DISTANCE BETWEEN MODULES

 

Ä

 Maintain an interval of at least 0.39 in (10 mm) between two modules along the short side

 

Ä

 Maintain an interval of at least 0.20 in (5 mm) between two modules along the long side

MOUNTING OPTIONS CL1

 

Ä

Ensure, that the subconstruction does not run below the junction box.

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

MOUNTING OPTIONS FB1

 

Ä

Use M8 corrosion-proof screws and washers (min. diameter 0.63 in (16 mm)).

 

Ä

Ensure, that the connection cables of the junction box don‘t run between laminate and substructure.

• 

The fastening points are located on the backside of the module frame.

Module Selection

For detailed key electrical data, please refer to the product data 
sheet for the respective product. 

 

Ä

Only connect modules of the same type and the same power 
class.

Safety Factor

During normal operation, a module may generate a greater current 
and / or higher voltage than that determined under standardized test 
conditions. Please use a safety factor of 1.25 for the following:

• 

Calculating the voltage measurement values (V

oc

) of components 

• 

Calculating the current measurement values (I

SC

) of conductors

• 

Sizing of control systems connected to the outlets of the solar 
modules 

 

Ä

Please follow the valid national guidelines for the installation 
of electrical systems (refer to section 690-8 of the NEC for an 
additional multiplying factor of 125 percent [80 percent derating] 
which may be applicable).

Series Connection

Connection of modules in series is only permitted up to the 
maximum system voltage as listed in the applicable data sheet.  

 

Ä

Take into account all possible operating situations and all relevant 
technical norms and regulations when designing the system. 
This will ensure that the maximum system voltage, including all 
necessary safety margins, is not exceeded. 

 

Ä

Take the voltage limit of the inverter into account when determining 
the maximum number of modules in the string.

Parallel Connection

Modules may be damaged by the occurrence of reverse currents 
(caused by module defects, ground leaks, or defective insulation).

 

Ä

Ensure that the maximum reverse current load capacity indicated 
in the data sheet is observed. 

In order to limit reverse currents that may occur, we recommend 
using the following safety options:

1)  Layout with a limited number of parallel connected strings :

Without undertaking further current blocking measures, a maximum 
of two module strings may be operated in parallel on an inverter or 
MPP tracker.

2)  Layout with string fuses :

Place fuses for each string of modules at the plus and minus ends. 
Observe the maximum permitted number of strings as indicated 

in the specifications provided by the respective string fuse manu

-

facturer and the technical guidelines.

NOTE! 

When installing different product versions, the lowest minimum 
permitted reverse current load capacity applies.  

Inverters

Inverters with or without transformers may be used.

2.4  Electrical layout

2 PLANNING

Содержание Q.PRO L-G2

Страница 1: ...Valid for North America Q PRO L G2 INSTALLATION AND OPERATION MANUAL ...

Страница 2: ...Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Units Where both metric and U S units for example inches are shown metric units are definitive References to Data Sheet or Module Data Sheet refer to the Module Data Sheet applicable to the module being used Safety Regulations The solar module operator is responsible for compliance with all a...

Страница 3: ...ing the formal requirements for solar power systems Ä Ä Please be sure to contact the relevant local authorities and energy providers regarding regulations and permit requirements prior to installation of the solar power system Your financial success depends on the fulfillment of these requirements Other applicable documents This installation manual is only valid in combination with the following ...

Страница 4: ... expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ä Ä Ensure that the clamps and the mounting frame are compatible Clamp System Requirements Use customary clamps that comply with the requirements Clamp width 1 50in 38 mm Clamp height compliant with a 1 57in 40 mm frame height ...

Страница 5: ...omponents Calculating the current measurement values ISC of conductors Sizing of control systems connected to the outlets of the solar modules Ä Ä Please follow the valid national guidelines for the installation of electrical systems refer to section 690 8 of the NEC for an additional multiplying factor of 125 percent 80 percent derating which may be applicable Series Connection Connection of modu...

Страница 6: ...cool and dry rooms The packaging is not weatherproof DANGER Risk of fatal injury due to electric shock Ä Ä Do not install damaged modules Ä Ä Inform your vendor of any damages immediately 3 1 Safety and transport 3 INSTALLATION NOTE Module damage may occur Ä Ä Do not drop modules NOTE Module damage may occur Ä Ä Only make modifications to the module which have been confirmed in writing by Q CELLS ...

Страница 7: ...nly use dry insulated tools Ä Ä Do not carry out the installation alone Only install undamaged modules and components Ä Ä Do not drill any other holes e g do not drill any additional holes 3 2 Preparation of installation 3 INSTALLATION Ä Ä Maintain an interval of at least 0 39 in 10 mm between two modules along the short side and 0 20 in 5 mm along the long side 0 39 in 10mm 0 2 0 i n 5 m m Option...

Страница 8: ...ior to separation Ä Ä Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge DANGER Risk of fatal injury due to electric shock Ä Ä Never open the junction box Ä Ä Change of bypass diodes is only allowed by qualified and trained personnel in disconnected and covered state DANGER Risk of fatal injury due to electric shock Ä Ä N...

Страница 9: ...hat all electrical components are in a proper dry and safe condition A module with min 47 24 in 1 200 mm long cable in portrait orientation can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return cable Standard wiring with a return cable Inverter Inverter 1 2 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ä Ä Ensure that all necessary safety and functional tests have been ...

Страница 10: ...ame section drawing To install the grounding lug follow the specified instructions of the manufacturer The grounding lug should be made of stainless steel or tin plated metals such as aluminum to avoid corrosion The grounding lug should be attached to the frame grounding hole using a stainless steel screw toothed lock washer or KEPS nut in order to penetrate the anodized layer and backing nut Care...

Страница 11: ... access the installation area alone or without taking adequate security precautions Ä Ä Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Ä Ä Remove snow and ice without force e g with a very soft broom Ä Ä Do not scratch off dirt Ä Ä Rinse dirt off with lukewarm water dust leaves etc Ä Ä Use a soft cellulose cloth kitchen roll or sponge to care...

Страница 12: ...ORP 300 Spectrum Center Drive Suite 1250 Irvine CA 92618 USA TEL 1 848 748 59 96 EMAIL q cells usa q cells com WEB www q cells us Subject to change without notice Hanwha Q CELLS GmbH Installation manual Q PRO L G2_2015 06_Rev02_NA ...

Отзывы: