4
5
INSTALLATION AND OPERATION MANUAL SOLAR MODULES – Q.PRO L-G4.1, Q.PRO L-G4.2, Q.PLUS L-G4.1, Q.PLUS L-G4.2 – NA
INSTALLATION AND OPERATION MANUAL SOLAR MODULES – Q.PRO L-G4.1, Q.PRO L-G4.2, Q.PLUS L-G4.1, Q.PLUS L-G4.2 – NA
Validity
These instructions are only valid for crystalline solar modules
from the company Hanwha Q CELLS. Hanwha Q CELLS assumes
no liability for damage resulting from failure to observe these
instructions.
Ä
Please observe the wiring and dimensioning of the system.
Ä
The installer of the system is responsible for compliance with all
necessary safety regulations during set-up and installation.
Hanwha Q CELLS assumes no liability on the basis of these
instructions. Hanwha Q CELLS is only liable in the context of
contractual agreements or in the context of accepted guarantees.
Hanwha Q
CELLS accepts no other responsibility for the
functionality and safety of the modules.
Ä
Please observe the instructions for any other system components
that may be part of the complete solar power system. It may be
necessary to carry out a structural analysis for the entire project.
Ä
If your questions are not satisfactorily answered in the
manual, please contact your system supplier.
•
The information contained within this document is subject to
change without notice.
Additional information can be found on our website at
www.q-cells.com.
Information for the Operator
Ä
Please keep this manual for the entire life of the solar power
system.
Ä
Please contact your system supplier for information concerning
the formal requirements for solar power systems.
Ä
Please be sure to contact the relevant local authorities and energy
providers regarding regulations and permit requirements prior
to installation of the solar power system. Your financial success
depends on the fulfillment of these requirements.
Other applicable documents
This installation manual is only valid in combination with the
following technical information.
DOCUMENT TYPE
Product data sheet
Packaging and transport information
1 INTRODUCTION
2.1 Technical specifications
2 PLANNING
Fig. 1:
External dimensions (inch and mm) and components for Q.PRO L-G4.1,
Q.PRO L-G4.2, Q.PLUS L-G4.1, Q.PLUS L-G4.2
C-SI MODULES (L) FOR DATA SHEETS
≥
47.24'' (
≥
1200 mm)
39.4''
(1000 mm)
51.5'' (1308 mm)
78.5'' (1994 mm)
1.38" (35 mm)
Junction bo×
4 × Mounting slots (DETAIL A)
8 × Drainage holes 0.12 × 0.24" (3 × 6 mm)
Cable with
connectors
Frame
6 × Grounding holes, Ø 0.18'' (4.5 mm)
DETAIL A
0.63" (16 mm)
0.33" (8.5 mm)
1.0" (25.5 mm)
37.4''
(949 mm)
4 × Drainage holes 0.47 × 0.47" (11.9 × 11.9 mm)
DETAIL B
0.39" (10 mm)
0.28" (7 mm)
0.98" (25 mm)
4 × Mounting slots system Tracker (DETAIL B)
37.4''
(950 mm)
15.7'' (400 mm)
5.91''
(150 mm)
NA
Additional information can be found in the currently valid data sheets available at www.q-cells.com.
PRODUCT LINE
Q.PRO L-G4.1
Q.PLUS L-G4.1
Q.PRO L-G4.2
Q.PLUS L-G4.2
Type
Polycrystalline
Q.ANTUM
Polycrystalline
Q.ANTUM
Length [in]
78.5 (1994 mm)
78.5 (1994 mm)
78.5 (1994 mm)
78.5 (1994 mm)
Width [in]
39.4 (1000 mm)
39.4 (1000 mm)
39.4 (1000 mm)
39.4 (1000 mm)
Frame height [in]
1.38 (35 mm)
1.38 (35 mm)
1.38 (35 mm)
1.38 (35 mm)
Weight [lb]
52.9 (24 kg)
52.9 (24 kg)
52.9 (24 kg)
52.9 (24 kg)
Max. system voltage V
SYS
[V]
1500 (IEC) / 1000 (UL)
1500 (IEC) / 1000 (UL)
1500 (IEC) / 1500 (UL)
1500 (IEC) / 1500 (UL)
Max. fuse rating [A]
15
15
15
15
Permissible temperature
range [°F (°C)]
–40 to +185 (–40 to +85)
Junction box protection
class
≥
IP67 with bypass
diodes
≥
IP67 with bypass
diodes
≥
IP67 with bypass
diodes
≥
IP67 with bypass
diodes
Connector protection class
IP68
IP68
IP68
IP68
Fire protection class
C / Type 1
C / Type 1
C / Type 1
C / Type 1
Wind / Snow load
1
[lbs/ft
2
]
50 (2400 Pa) /
112 (5400 Pa)
50 (2400 Pa) /
112 (5400 Pa)
50 (2400 Pa) /
112 (5400 Pa)
50 (2400 Pa) /
112 (5400 Pa)
Max. Load (UL) [lbs/ft²]
75 (3600 Pa)
75 (3600 Pa)
75 (3600 Pa)
75 (3600 Pa)
Load Rating (UL) [lbs/ft²]
33 (1600 Pa)
33 (1600 Pa)
33 (1600 Pa)
33 (1600 Pa)
Certificates
CE-compliant; IEC 61215 (Ed.2) see page 8; IEC 61730 (Ed.1) Application Class A;
UL 1703
1
Test-load in accordance with IEC 61215