background image

Printed  in  Japan  04.09.22.000 

 

INTRODUCTION 

 

Thank you for choosing SANYO HIT PV 

modules. With proper operation and 

maintenance, SANYO HIT PV modules 

will provide you with clean, renewable 

solar electricity for many years.   

Retain this manual for reference. This 

manual contains important information 

about installation, maintenance and 

safety.   

Please retain it for future reference. 

 

Disclaimer of Liability 

SANYO does not assume responsibility 

and expressly disclaims liability for loss, 

damage, or expense arising out of or in 

any way connected with such installation, 

operation use or maintenance by using 

this manual.   

SANYO assumes no responsibility for 

any infringement of patents or other 

rights of third parties that may result from 

use of the module.   

No license is granted by implication or 

under any patent or patent rights. The 

information in this manual is believed to 

be reliable, but does not constitute an 

expressed and implied warranty.   

SANYO reserves the right to make 

changes to the product, specifications, or 

manual without prior notice. 

 

General Information 

The installation of solar modules requires 

a great degree of skill and should only be 

performed by qualified licensed 

professional, including, without limitation, 

licensed contractors and licensed 

electricians.   

 

 

 

 

 

All instructions should be read 

and understood before attempting to 

install, wire operate and maintain the 

photovoltaic module. Contact with 

electrically active parts of the module 

such as terminals can result in burns, 

sparks, and lethal shock whether the 

module is connected or 

disconnected. 

The installer assumes the risk of 

all injury that might occur during 

installation, including, without 

limitation, the risk of electric shock. 

PV modules generate DC 

electrical energy when exposed to 

sunlight or other light sources.   

Although single modules produce 

only a low voltage and current, 

shocks and burns are still a potential 

hazard.     

To avoid the hazard of electric 

shock and injury, cover all over the 

front surface of PV modules with a 

dense opaque material such as the 

cardboard box during installing and 

handling modules. 

The shock hazard increases as 

modules are connected in parallel 

producing higher current.    The 

shock hazard increases as modules 

are connected in series producing 

higher voltages. 

To avoid the hazard of electric 

shock, work only under dry 

conditions, with dry module and 

tools. 

Do not stand or step on a 

module to avoid the hazard of injury 

and the damage to a module. 

Do not damage the back sheet of 

a module, to avoid the hazard of 

electric shocks and fire.

 

To avoid the hazard of electric 

shock and injury, Children and 

unauthorized persons should not be 

allowed near the installation of the 

solar cell modules. 

To avoid the hazard of electric 

shock and injury, be sure to ground 

the modules completely. 

To avoid the hazard of electric 

shock, fire and injury, do not 

disassemble the module, or remove 

any part installed by the 

manufacturer. 

Unauthorized persons except 

the qualified licensed professional 

should not open the cover of the 

junction box to avoid the hazard of 

electric shock. 

Do not touch terminals while a 

module(s) is exposed to light. 

Provide suitable guards to prevent 

yourself contacting directly with 30 

VDC or greater to avoid the hazard of 

electric shock or injury. 

When carrying a module, more 

than two persons should carry it by 

the frame and wear non-slip gloves to 

avoid the hazard of injury by slipping 

down the module on a foot or cutting 

by an edge of the frame and so on. 

Do not carry a module by wire or 

junction box to avoid the hazard of 

electric shock and injury or any 

troubles in a module, which it may 

cause. 

Do not drop anything on the 

surfaces of modules to avoid the 

hazard of electric shock and injury or 

any troubles that it may cause. 

To avoid the hazard of electric 

shock and fire, be sure that other 

system components do not cause 

any hazard of any mechanical or 

electrical nature to the module. 

Since sparks may be generated, 

do not install module where 

flammable gases or vapors are 

present. 

Never leave a module 

unsupported or unsecured.      Do not 

drop module and do not allow 

objects to fall on module to avoid the 

hazard of injury or any troubles in 

modules that it may cause. 

Do not use or install broken 

modules to avoid the hazard of 

electric shock and injury. 

Do not artificially concentrate 

sunlight on module to avoid the 

hazard of fire or any trouble. 

Do not touch the Junction box 

terminals to avoid the hazard of 

electric shock and injury. 

Do not change wiring of bypass 

diodes to avoid the hazard of electric 

shock and injury. 

 

 

 

 

 

Use module for its intended 

function only.     

Do not treat the back sheet and 

front surface with paint or adhesives 
to avoid any troubles.

 

General Installation Manual 

General Installation Manual for SANYO HIT Photovoltaic (PV) Modules. 
Please read this manual completely before installing or using the modules. 
This manual is applied for the following products:

HIP-190BE3, HIP-180BE3, HIP-175BE3, HIP-167BE3

 

CAUTIONS 

W A R N I N G 

Summary of Contents for HIP-190BE3

Page 1: ...n a module to avoid the hazard of injury and the damage to a module Do not damage the back sheet of a module to avoid the hazard of electric shocks and fire To avoid the hazard of electric shock and injury Children and unauthorized persons should not be allowed near the installation of the solar cell modules To avoid the hazard of electric shock and injury be sure to ground the modules completely ...

Page 2: ... to avoid partially shading modules by something in daytime Please contact your local dealer with questions regarding mounting profiles for modules Notes on Installation Clearance between the module frame and the mounting surface is required to allow cooling air to circulate around the back of the module This also allows any condensation or moisture to dissipate The module should never be sealed t...

Page 3: ...its damage All modules connected in series should be of the same model number type Do not connect modules in parallel without using a connection box Mechanical Electrical Specifications Electrical Specification Model HIP 190BE3 HIP 180BE3 HIP 175BE3 HIP 167BE3 Cell Number in Series Pieces 96 96 96 96 Maximum Power Pmax W 190 180 175 167 Maximum Power Voltage Vmp V 54 8 54 0 52 9 51 4 Maximum Power...

Page 4: ... of the junction box see Fig3 DIODES Bypass Diodes When the modules in series strings are shaded partially it may cause a reverse voltage across cells or modules because the current from other cells in the same series is forced to flow through the shaded area and then undesirable heating may occur The use of a diode to bypass the shaded area can minimize both heating and reduction of array current...