© 2000 Directed Electronics, Inc. Vista, CA
5
■
A
latched/reset with ignition
output works similar to the latched output, but will also reset (output will
stop) when the ignition is turned on and then off.
■
A
30 second timed
output will send a signal for 30 seconds when channel three is pressed. This output can
be shut off during the 30-second period by pressing Channel 3 again.
■
This output can also be programmed to provide a
second unlock pulse
when the disarm button is pressed
within 15 seconds after disarming the system. This can be used to unlock the passenger doors when installing
progressive door locks.
IMPORTANT!
Never use this wire to drive anything but a relay or a low-current input! This
transistorized output can only supply 200 mA, and connecting directly to a solenoid, motor, or other
high-current device will cause the module to fail.
H1/4 BLACK/WHITE (-) 200 MA DOMELIGHT SUPERVISION OUTPUT
Connect this wire to the optional domelight supervision relay as shown below:
IMPORTANT!
This output is only intended to drive a relay. It cannot be connected directly to the
domelight circuit, as the output cannot support the current draw of one or more bulbs.
H1/5 GREEN (-) DOOR TRIGGER INPUT, ZONE 3
Most vehicles use negative door trigger circuits. Connect the green wire to a wire showing ground when any door is
opened. In vehicles with factory delays on the domelight circuit, there is usually a wire unaffected by the delay circuitry.
This wire will report Zone 3.